BEGA 85153K4 Performance Floodlight Instruction Manual
- July 20, 2024
- BEGA
Table of Contents
BEGA 85153K4 Performance Floodlight Instruction Manual
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories. For a variety of interior
and exterior lighting applications.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
Matt safety glass
Silicone gasket
Reflector surface made of pure aluminium
BEGA Hybrid Optics®
Rotation range of floodlight 350°
Swivel range -30°/+95°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical impacts < 5 joule
– Conformity mark
Wind catching area: 0.053 m²
Weight: 5.9 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm. Secure the screw connection from
loosening on site (if provided with locking screw S , see fig. A ).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 6 mm) and hexagon nut (wrench size 30
mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 12 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screw (wrench size 2 mm, see sketch B ).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow ( ), the phase to the brown (L), and the neutral
conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Lamp
Module connected wattage 72.9 W
Luminaire connected wattage 78 W
Rated temperature = 25 °C
Ambient temperature = 35 °C
85 153 K3
Module designation LED-0877/930
Colour temperature 3000 K
Colour rendering index CRI > 90
Module luminous flux 9980 lm
Luminaire luminous flux 4987 lm
85 153 K4
Module designation LED-0877/940
Colour temperature 4000 K
Colour rendering index CRI > 90
Module luminous flux 9830 lm
Luminaire luminous flux 5063 lm
Luminaire luminous efficiency 64,9 lm / W
Luminaire luminous efficiency 63,9 lm / W
Lighting technology
Focused light distribution with minimal diffuse light percentage.
Half beam angle 11°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable between mounting box and floodlight has to be inspected regarding obvious damages and has to be replaced by a qualified electrician only.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counter-clockwise.
Replace LED module.
Please follow the installation instructions for the
LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop. Tighten locking pin.
Accessories
71 292 Optical filter flat beam
71 334 Shield
71 339 Cylindrical shield
70 214 Pole cap for pole top ø 48 mm
70 248 Pole cap for pole top ø 60 mm
70 249 Pole cap for pole top ø 76 mm
70 229 Pole cap for pole top ø 82 mm
70 245 Mounting box · rectangular
70 280 Tube clamp
70 379 Cross beam
70 889 Lashing strap
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass 25 000 256
Trim ring silver with glass 25 000 257
LED power supply unit DEV-0356/1400i
LED module 3000 K LED-0877/930
LED module 4000 K LED-0877/940
Reflector 75 004 998
Gasket housing 83 001 780
Gasket trim ring 83 002 225
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>