Ceiling and wall luminaire
Instructions for use
Application
Unshielded ceiling and wall luminaire with high protection class.
A luminaire made of die cast aluminium and with an impact resistant synthetic
diffuser.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Impact resistant synthetic diffuser,
BEGA NeoGlass® · diffuse white
2 mounting holes ø 4.8 mm
Distance apart 150 mm
2 cable entries for through-wiring of mains supply cable ø 7-12 mm
Connecting terminal and earth conductor terminal 2.5▫
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V x 0/50-60 Hz
DC 176-280 V
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
– Conformity mark
This product contains light sources of energy efficiency class(es) C
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components. You can find them on our
website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.
Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
The synthetic cover is fastened to the luminaire base via 4 spring-locking
mechanisms. To remove the synthetic cover, unlock the 4 spring-locking
mechanisms (as illustrated in the diagram) one after another by applying light
pressure with a screwdriver.
Lift off the synthetic cover.
For mounting the luminaire base and the electrical connection, loosen the 2
screws (Torx drive T10) of the LED PCB and remove the LED PCB upwards
(keyholes).
While doing so, make sure that the LED PCB was not mechanically damaged.
Lead the mains supply cable through the cable entry of the luminaire base.
Fix luminaire base with enclosed or any other suitable fixing material onto
the mounting surface.
Make the earth conductor connection and the electrical connection.
In order to guarantee the maximum service life of the electrical components,
the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the
position marked by the red information label immediately before finally
closing the luminaire.
Insert the LED PCB into the luminaire base and tighten the mounting screws
uniformly.
Make sure that gasket is positioned correctly. Guide the synthetic cover with
the 4 mounting brackets into the recesses on the luminaire base and press down
evenly until all 4 mounting brackets engage audibly.
Lamp
Module connected wattage 6.5 W
Luminaire connected wattage 7.6 W
Rated temperature = 25 °C
Service life criteria 50 000 h / L₇₀
24 892 K3
Module designation LED-1539/830
Colour temperature 3000 K
Colour rendering index CRI > 80
Module luminous flux 1435 lm
Luminaire luminous flux 920 lm
Luminaire luminous efficiency 121,1 lm / W
- preliminary data
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation
instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Spares
Synthetic cover 15 000 818
LED power supply unit DEV-0451/350
LED module 3000 K LED-1539/830
Gasket 83 002 314