BEGA 51299.5K3 Wall Luminaire For Indoor Use Instruction Manual

July 16, 2024
BEGA

Technical amendments reserved
**Wall luminaire for indoor use

51 299.5
BEGA 51299.1K3 Wall Luminaire For Indoor UseInstructions for use**

Application

Wall luminaire · Indoor luminaire with 3 ring-shaped light sources for unshielded and uniform light, light-diffusing silicone diffusers and metal rings.
As single luminaires or in arrangements, they are creative lighting design solutions for interior design.

Product description

Ring made of metal and luminaire housing made of synthetic material, surface colour velvet black
Round inlay made of metal, finish colour velvet black
Diffusor made of translucent ageing-resistant silicone
Mounting plate with 2 fixing holes ø 6 mm · 85 mm spacing 2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5
Connecting terminals 2.5
Earth conductor connection
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 196-250 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
– Conformity mark
Weight: 1.2 kg
This product contains light sources of energy efficiency class(es) D

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against eg transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com .

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp

Module connected wattage 34.8W
Luminaire connected wattage 38.5W
Rated temperature t a = 25 °C
Ambient temperature tamax = 40 °C

51 299.1 K3

Module designation 3x LED-1460/930
Colour temperature 3000K
Colour rendering index CRI> 90
Module luminous flux 5400lm
Luminaire luminous flux 3295lm
Luminaire luminous efficiency 85.6 lm / W

installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the hexagon socket head screw (wrench size 1,5 mm) and remove mounting plate from luminaire housing.
Pass the power connecting cable through the cable entry in the mounting plate.
Note position of application of the mounting plate “arrow down”.
Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
Establish earth conductor connection to the earth conductor connection screw and make the electrical connection to the terminals.
The two connecting terminals marked DA, DA are provided for digital control purposes.
If these terminals are not assigned, the luminaire will work with full light output.
Insert the connection terminals into the luminaire housing.

BEGA 51299.1K3 Wall Luminaire For Indoor Use - fig

Position the luminaire housing in a flat inclination angle over the fastening edge of the mounting plate and swing in.
Align luminaire housing and tighten (max. 0.25 Nm) hexagon socket screw (wrench size 1.5).

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
It is also listed in the spare parts overview at the end of these instructions for use.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by a qualified person using commercially available tools.
Disconnect the system from the power supply.
Undo the hexagon socket head screw (wrench size 2.5 mm) and remove luminaire from mounting plate.
Remove the connecting lines from the terminals and place the front of the luminaire on a soft surface.

Open the luminaire housing:
First, loosen the 6 inner Torx screws (T20) by 3 or 4 turns.
Then fully unscrew the 3 outer Torx screws (T20).
To remove the bottom part of the housing from the top part of the housing, it is necessary to exert pressure on the 5 snap-in hooks until they are released from their locking mechanism.
Disconnect the lines of the luminaire cable from the 4 terminals and remove the terminals.
Remove the LED module with the diffuser from the holder. Install the replacement module.
Please follow the installation instructions for the new LED module.
A defective LED module (silicone diffuser) must be replaced.
Close the luminaire housing:
When positioning, ensure the necessary power supply unit passthrough for the bottom part of the housing.
Place the bottom part of the housing onto the top part of the housing exerting gentle pressure and let the snap-in hook engage.
Reinsert the previously removed 3 outer Torx screws (T20) and tighten (max. 1.2 Nm).
Finally, retighten the 6 inner Torx screws (T20).
Re-attach the terminals to the wires of the luminaire cable.
Make the electrical connection to the terminals.
Observe the correct configuration of the connecting cable. Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
The two connecting terminals marked DA, DA are provided for digital control purposes.
If these terminals are not assigned, the luminaire will work with full light output.
Position the luminaire housing at a flat inclination angle over the fastening edge of the mounting plate and swing in.
Align luminaire housing and tighten (max. 0.25 Nm) hexagon socket screw (wrench size 1.5).

Spares

LED power supply unit DEV-0305/700i
LED modules 3000 K LED-1460/930

BEGA Gantenbrink-Leuchten KG ·
PO Box 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com

Documents / Resources

| BEGA 51299.5K3 Wall Luminaire For Indoor Use [pdf] Instruction Manual
51299.5K3 Wall Luminaire For Indoor Use, 51299.5K3, Wall Luminaire For Indoor Use, For Indoor Use, Indoor Use, Use
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals