Operation
Bogey board works out of the box. Connect no-volt switched(es) and deploy.
Connect Power supply or Battery (CR2032 supplied)
Pairing BOGEYBOARD to a Radio Receiver
In any Remote Control the Receiver “learns” the transmitted signal from
each BOGEYBOARD input please follow the Receiver instructions for pairing.
Configuring Modes of Operation
The Menu Switch is used to Select Menu Options.
Menu 2 : Enable/Disable Acknowledge signal back from Receiver
Menu 3 : Configure BOGEYBOARD to operate with a Momentary Push or
latching Switch
BOGEYBOARD Factory Default Settings
Menu | Default Setting |
---|---|
2: Acknowledgment | Acknowledgement Request is ON |
3: Switch Input | Momentary Push Switch |
Safety Information
Carefully read the following safety information before proceeding with installation, operation, or maintenance of RF Solutions product. Failure to follow these warnings could result in death or serious injury.
- This radio system must not be used in areas where there is a risk of explosion.
- Only qualified personnel should be permitted to access the transmitter and operate the equipment.
- Always follow operating information as well as all applicable safety procedures and requirements.
- You must satisfy the age requirements in your country for operating the equipment.
- Store in a safe place.
- Keep a clear view of the work area at all time before using, check it is safe to do so Before maintenance intervention on any remote controlled equipment
- Do not open the receiver enclosure unless you are qualified.
- Disconnect all electrical power from the equipment.
- Check the enclosure and cable for damage regularly, do not use if there is evidence of damage
Battery Precautions
- Risk of explosion if battery is replaced with a battery of an incorrect type.
- Do not short-circuit, disassemble, deform or heat batteries.
- Never attempt to charge a visibly damaged or frozen battery.
- Do not use or charge the battery if it appears to be leaking, deformed or damaged in any way.
- Immediately discontinue use of the battery if, while using, charging, or storing the battery, the battery emits an unusual smell, feels hot, changes color, changes shape, or appears abnormal in any other way.
- Keep batteries out of reach of small children. Should a child swallow a battery, consult a physician immediately.
Menu 2 Acknowledgement Request
When activated the BOGEYBOARD requests an acknowledgement back from the
receiver. If an acknowledgement is not received, BOGEYBOARD will retry again
(up to 4 times) until an acknowledgement is received.
If you are using a BOGEYBOARD to operate multiple receivers at the same time
(one to many) we recommend turning OFF the acknowledgement to avoid RF
contention with the Ack signals
Press Switch To select
LED ON : Acknowledgement
LED OFF: NO Acknowledgement After selecting wait for timeout
Menu 3 Momentary or Latching Switch Input
Momentary Switch Input (Continuous RF Transmit)
BOGEYBOARD continuously transmits “INPUT CLOSED”.
If the Acknowledgment request is ON the receiver will reply after each RF
transmission burst.
This is suited to momentary “push to make” Switch types.
Latching Switch Input (State Change Transmit)
BOGEYBOARD transmits when the input is OPENED or CLOSED i.e. a state change
only
Repeat Press Switch To select
LED OFF: Latch Switch
LED ON: Mom Switch
After selecting wait for timeout
External Antenna Option
Carefully cut the supplied antenna
RF Solutions offer several lengths of Coax Cable assembly CBA-UFLSMA which
plugs directly onto the UFL Antenna connector on the BOGEYBOARD and provides a
panel mount SMA connector.
ANT-GSM5WM
- Wall mount antenna
- 3m cable
- Active gain: +5dB
- RG58 Coax
ANT-PUKDB
- Vandal Proof Panel Mount
- 1.5m Coax to SMA
- 433 / 868MHz
- Active gain: +2dB
Restore BOGEYBOARD to Factory Default Settings
Simplified Declaration of Conformity (RED)
Hereby, RF Solutions Limited declares that the radio equipment type defined
within this document is in compliance with Directive 2014/53/EU.
The full text of the EU declaration of conformity is available at the
following internet address:
www.rfsolutions.co.uk
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2011/65/EU and amendment 2015/863/EU
Specifies certain limits for hazardous substances.
WEEE Directive 2012/19/EU
Waste electrical & electronic equipment. This product must be disposed of
through a licensed WEEE collection point. RF Solutions Ltd., fulfils its WEEE
obligations by membership of an approved compliance scheme, environment agency
registration number: WEE/JB0104WV.
Waste Batteries and Accumulators Directive 2006/66/EC
Where batteries are fitted, before recycling the product, the batteries must
be removed and disposed of at a licensed collection point.
RF Solutions battery producer number BPRN00060.
Disclaimer:
Whilst the information in this document is believed to be correct at the time
of issue, RF Solutions Ltd does not accept any liability whatsoever for its
accuracy, adequacy or completeness. No express or implied warranty or
representation is given relating to the information contained in this
document. RF Solutions Ltd reserves the right to make changes and improvements
to the product(s) described herein without notice. Buyers and other users
should determine for themselves the suitability of any such information or
products for their own particular requirements or specification(s). RF
Solutions Ltd shall not be liable for any loss or damage caused as a result of
user’s own determination of how to deploy or use R F Solutions Ltd’s products.
Use of RF Solutions Ltd products or components in life support and/or safety
applications is not authorised except with express written approval. No
licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s
intellectual property rights. Liability for loss or damage resulting or caused
by reliance on the information contained herein or from the use of the product
(including liability resulting from negligence or where RF
Solutions Ltd was aware of the possibility of such loss or damage arising) is
excluded. This will not operate to limit or restrict RF Solutions Ltd’s
liability for death or personal injury resulting from its negligence.