RF Solutions MAINSLINK-9 Wireless MAINS Switch Remote Control User Guide

June 9, 2024
RF SOLUTIONS

RF-Solutions-logo

Installation

RF-Solutions-MAINSLINK-9-Wireless-MAINS-Switch-Remote-Control-fig-
\(1\)

Connect the Switched Input L

When this input is ’LIVE’ the Red LED will illuminate, and MAINSLINK-RX will then switch Live out at its output.RF-Solutions-MAINSLINK-9-Wireless-MAINS-
Switch-Remote-Control-fig- \(2\)

Connect

  1. Permanent LIVE and NEUTRAL supply.
  2. Your Load to LIVE OUT.

Note: Live In Terminal is Not Used.

When the Live Output (LOUT) is LIVE the Red LED will illuminate.

Application example

WORCESTER-BOSCH Boiler Installation:

RF-Solutions-MAINSLINK-9-Wireless-MAINS-Switch-Remote-Control-fig-
\(3\)

Operation
When the Boiler switches the Pump ON, MAINSLINK-TX is switched Live, then, MAINSLINK-RX Lout will automatically switch the pump on.

Warnings:

  • Product is not independently isolated, ISOLATE the mains electricity supply before removing the cover and observe any relevant safety precautions. Maintenance of the product that involves the removal of the cover should only be carried out by a competent person or qualified electrician.
  • The F2 Fuse rating is 4A (T) 250 H (Ceramic). Replace the fuse with the same type and rating.
  • Relay is rated at 10A peak, and 5A constant.
  • The product must be connected to a switch fused spur/supply or BS1363 Plug. A single Fuse Spur is recommended to supply the Boiler and MAINSLINK jointly so that they are isolated together.

Jumper Link Setting:
There are three Jumper Links that may be used to configure the following:RF-
Solutions-MAINSLINK-9-Wireless-MAINS-Switch-Remote-Control-fig-
\(4\)

WDOG: WATCHDOG:
This provides improved reliability and security, useful with electrically noisy Loads. When the WDOG links are fitted MAINSLINK-TX automatically sends a repeating background “watchdog” RF signal and MAINSLINK-RX expects to receive this signal. If the WDOG signal is not received within 90 seconds, the output will drop out and the comms LED will flash. In the event of a Power Loss at the receiver, if the transmitter is ON the Watchdog signal will auto-recover the MAINSLINK-RX to Switch ON.

MODE:

  • FM: Fast operation with shorter range (Line of sight up to 500m/100m in buildings)
  • This mode is recommended for general operation.
  • LORA Mode 3: Slower operation Long range (Line of sight upto 5Km/1Km in buildings)
  • This mode can be used where additional RF penetration/range is required.
  • MOM/LAT – Momentary or Latching Output
  • MOMENATRY: Used for MAINSLINK TO MAINSLINK.
  • LATCHING: Select this when MAINSLINK-RX is controlled by a Remote transmitter e.g. pocket keyfob.

Switching Lower Power LED Lights

Mainslink-RX incorporates a “snubber” protection circuit which is recommended with Inductive Loads such as a Motor or pump. If switching lower power LED lighting the snubber circuit can cause the LED lights to faintly glow when switched off. To remove the snubber, remove Jumper link J2 on the rear of the PCB (as the image shows).

NOTE: This system does not require pairing, they are supplied and ready to operate!

  1. Apply a 230Vac supply to the MAINSLINK-RX
  2. Briefly swipe a magnet along the right side as shown
  3. The GREEN comms LED will flash 3 times to show “in Pairing Mode”.RF-Solutions-MAINSLINK-9-Wireless-MAINS-Switch-Remote-Control-fig- \(6\)
  4. Apply a 230Vac supply to the MAINSLINK-TX
  5. Briefly swipe a magnet along the right side as shown
  6. MAINSLINK-TX will now send a special Pairing message
  7. The MAINSLINK-TX and MAINSLINK-RX will now Auto pair together – allow 15 secs.

To erase the system hold a magnet beside the top right side of the enclosure until the Green COMS LED is ON solid (about 5 seconds).

Simplified Declaration of Conformity (RED)

Hereby, RF Solutions Limited declares that the radio equipment type defined within this document is in compliance with Directive 2014/53/EU. The full text of the EU declaration of conformity is available at the following internet address: www.rfsolutions.co.uk.

RF Solutions Ltd. Recycling Notice

Meets the following EC Directives:
DO NOT Discard normal waste, please recycle.

ROHS Directive 2011/65/EU and amendment 2015/863/EU
Specifies certain limits for hazardous substances.

WEEE Directive 2012/19/EU
Waste electrical & electronic equipment. This product must be disposed of through a licensed WEEE collection point. RF Solutions Ltd. fulfills its WEEE obligations by membership in an approved compliance scheme. Environment agency number: WEE/JB0104WV.

Waste Batteries and Accumulators Directive 2006/66/EC
Where batteries are fitted, before recycling the product, the batteries must be removed and disposed of at a licensed collection point. RF Solutions battery producer number: BPRN00060.

Disclaimer

Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express or implied warranty or representation is given relating to the information contained in this document.
RF Solutions Ltd reserves the right to make changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or products for their own particular requirements or specification(s).
RF Solutions Ltd shall not be liable for any loss or damage caused as a result of the user’s own determination of how to deploy or use RF Solutions Ltd’s products.

Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with express wrote
approval. No licenses are created, implicitly or otherwise, under any of RF Solutions Ltd’s intellectual property rights. Liability for loss or damage
resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where
RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd’s liability for death or personal injury resulting from its negligence.

RF Solutions Ltd
William Alexander House, William Way, Burgess Hill, West Sussex, RH15 9AG

Sales: +44 t0)1444 227900
Support: +44 (0)1444 227909
Website: www.rfsolutions.co.uk.

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals