RF Solutions UK TRAP9TX-2 TRAP 4 Button Lora Handheld Transmitter User Guide

June 17, 2024
RF Solutions UK

RF Solutions UK TRAP9TX-2 TRAP 4 Button Lora Handheld Transmitter

Product Information

Specifications:

  • Model: TRAP (LoRa) Transmitter
  • Power Source: 3xAAA Batteries
  • LED Indicators: Green (RF Transmit), Green/Red (RF Acknowledge), Low Battery

Product Usage Instructions

Operation:
Press any switch to operate the transmitter. The device will automatically sleep between operations to conserve power. The green LED indicates transmission activity.

Replacing Batteries:
To replace the batteries, follow the diagram provided in the manual for guidance on replacing the 3xAAA batteries.

Configuring Modes of Operation:
To configure the modes of operation, follow these steps:

  1. Undo the six enclosure fixing screws to access the internal circuit board.
  2. Use the SET switch to configure the operating modes.
  3. Refer to the manual for details on different modes and settings.

Continuous or State Change RF Transmissions:
To set continuous or state-change RF transmissions:

  1. Press the switch 3 times.
  2. LED1 will flash 3 times, then wait for 3 seconds.
  3. LEDs 1 & 2 will flash once, indicating the current status.
  4. The transmitter will transmit a Button Down RF signal when a switch button is pressed and a Button Up RF signal when released.

FAQ

  • How do I know if the battery needs to be replaced?
    If the Low Battery LED illuminates for 3 seconds after each operation, it indicates that the battery needs replacement.

Operation

  • Press any of the switches to operate.
  • The Transmitter will auto-sleep between operations to save power.
  • RF Transmit GREEN LED operates when TRAP is transmitting an RF signal.

RF Acknowledge (if configured):

  • GREEN LED will flash at high speed to indicate that an acknowledgment has successfully been received back from the receiver.
  • The RED LED will flash at high speed to indicate that an acknowledgment has not been received back from the receiver.
  • Low Battery: If the battery requires replacing, Low Battery
  • LED illuminates for 3 seconds after each operation.

Replacing transmitter batteries:
Follow the diagram to replace the 3xAAA batteries.

Configuring Modes of Operation
  • To configure the modes of operation, undo the six enclosure fixing screws to access the internal circuit board.
  • The SET switch is used to configure the operating modes.
  • Note: Please also see the Video on our website!

The Following Modes can be configured using the Switch

  1. RF Mode of transmission
  2. Acknowledgement back from the receiver
  3. Continuous or State Change transmission

Transmitters are factory Settings

Transmitters are factory shipped with the following Settings

RF Transmission LoRa 3
Acknowledgment OFF
Transmission Type Continuous

Restore to Factory Default Settings

To Set Continuous or State Change RF Transmissions

  • When a switch button is operated the transmitter will transmit a “Button Down” RF signal.
  • When a switch button is released the transmitter will transmit a “Button Up” RF signal.

Continuous Transmit

  • When the transmitter button is pressed the “button Down” RF signal is repeated in short bursts for as long as the button is pressed.
  • If the Acknowledgment request is ON the receiver will reply after each RF signal.
  • This is ideally suited to momentary operations where the receiver output needs to be active as long as the user presses down a TRAP Button.

State Change Transmit

  • When the transmitter button is pressed the “button Down” RF signal is sent a maximum of 4 times. (this can be seen as 4 x Green RF Transmissions).
  • When the transmitter buttons are released the “button Up” RF signal is sent a maximum of 4 times. (this can be seen as 4 x Green RF Transmissions)
  • If the Acknowledgment request is ON and no acknowledgement received after the fourth RF Transmission, the Red Ack fail LED will flash
  • If the acknowledgment is received the High Speed Green LED will flash and the Transmitter will cease to send any of the remaining 4 unsent RF transmissions

To Set Acknowledgement Request

  • The acknowledgement feature provides the user with an LED indication that the receiver has successfully received the transmitter’s signal.
  • When activated the Transmitter includes an acknowledgement request from the receiver within each radio transmission.
  • The response from the receiver is indicated on the transmitter via the acknowledge LED RED (no acknowledge received)
  • High-speed GREEN flash (acknowledge received).

RF Acknowledgment from Receiver – Warning!
When Acknowledgement is ON, the transmitter requests an RF signal back from the receiver. Whilst in theory, if an RF signal can be transmitted one way then it can be returned, in practice occasionally the received acknowledgement may not penetrate as well as the transmitter’s signal.

To Set the RF Transmission Mode

This sets the type of RF Transmission.

Possible options are

  • 868MHz: FM, or LORA Modes 1 – 4
  • 918MHz: LORA Modes 1 – 4

FM or LORA mode 1 provides the quickest response; from the Transmitter switch (Sw) pressed to the Receiver Relay output.

Notes

  1. The range is dependent on many factors including the mode of transmission. Range can be reduced by 75% in built-up areas with poor antenna and environmental conditions.
  2. Battery life quoted is approximate based on 30 operations per day.

Simplified Declaration of Conformity

Simplified Declaration of Conformity (RED)

Hereby, RF Solutions Limited declares that the radio equipment type defined within this document complies with Directive 2014/53/EU. The full text of the EU Declaration of conformity is available at the following internet address: www.rfsolutions.co.uk.

RF Solutions Ltd. Recycling Notice

Meets the following EC Directives:
DO NOT Discard normal waste, please recycle.

ROHS Directive 2011/65/EU and amendment 2015/863/EU
Specifies certain limits for hazardous substances.

WEEE Directive 2012/19/EU
Waste electrical & electronic equipment. This product must be disposed of through a licensed WEEE collection point. RF Solutions Ltd. fulfils its WEEE obligations by membership in an approved compliance scheme. Environment agency number: WEE/JB0104WV.

Waste Batteries and Accumulators Directive 2006/66/EC
Where batteries are fitted, before recycling the product, the batteries must be removed and disposed of at a licensed collection point. RF Solutions battery producer number: BPRN00060.

Disclaimer

Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or products for their own particular requirements or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result of the user’s determination of how to deploy or use RF Solutions Ltd’s products. Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with express written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where RF Solutions Ltd was aware of the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd’s liability for death or personal injury resulting from its negligence.

RF Solutions Ltd

  • William Alexander House, William Way, Burgess Hill, West Sussex, RH15 9AG
  • Sales: +44 (0)1444 227900
  • Support: +44 (0)1444 227909
  • www.rfsolutions.co.uk.