LEXON LH70 Bubble Lamp Instruction Manual
- June 30, 2024
- LEXON
Table of Contents
LEXON LH70 Bubble Lamp
IN THE BOX
- 1x LED desk lamp
- 1x USB-C cable
PRODUCT OVERVIEW
-
Lamp head
-
Touch button
-
Wireless charging surface
PRECAUTIONS FOR USE
1x User manual -
Output port (OUT)
-
LED indicators
-
Input port (IN)
- The light source of the lamp is an integrated LED module. Do not attempt to modify, service, repair or disassemble this lamp or the supplied cable yourself in any way.
- Place the desk lamp on a dry and flat surface.
- The Desk lamp is intended for indoor use. Do not place your lamp in very hot or cold areas.
- Always clean the lamp head and body with a soft cloth and do not use any cleaning materials that contain chemicals.
- Do not put metal objects or magnets bet.\Neen the mobile device and the wireless charging surface.
- Never place your device in water to avoid causing internal short-circuit, over-heating, fire, deformation, or even explosion of the battery.
- Keep your device out of reach of small children to prevent danger.
- Lexon cannot be held responsible for any malfunctions or damages resulting from failure to adhere to these instructions properly.
INSTALLATION INSTRUCTIONS
Important note: A power adapter (not supplied) with a minimum of 20W Output is
required.
To benefit from all charging features*, including pass-through USB-C we
recommend using a 60W Output adapter. If the input power is insufficient, the
lamp will flash slowly in orange. Make sure you follow the steps below:
- Step 1. Gently remove the Desk lamp from its protective housing.
- Step 2. Make sure your Desk lamp is in perfection condition.
- Step 3. Place it on a flat surface.
- Step 4. Connect a USB-C PD or QC power adapter (not supplied) to a wall outlet. plug the end of the supplied USB-C cable into the USB-C PD or QC power adapter.
- Step 5. Plug the other end into the input port (6).
LAMP FEATURES
- Turn ON the lamp by touching the touch button (2).
- Change the light color (9 colors options) by simply touching the touch button (2).
- Adjust the brightness by pressing and holding the touch button (2).
- To turn OFF the light, wait 3 seconds after the color selection then touch (2) again.
The last color set will be remembered for next time.
Note: If you want to set Bubble lamp in cool and warm light mode only, quickly
tap 3 times on the touch area (2). To return to full set lighting mode, repeat
the procedure.
WIRELESS CHARGING (A)
Bubble lamp is compatible with all Qi-enabled devices.
- Make sure your lamp is connected to a power source that delivers sufficient power (A).
- Place the mobile device supporting wireless charging face up at the center of the wireless charging surface (A).
- Once the mobile device is properly positioned and charging, the left LED on the back of the lamp will turn blue for 30 seconds then tum off.
WIRED CHARGING (D)
- Make sure your lamp is connected to a power source that delivers sufficient power (D).
- Plug your mobile device into the output port of the lamp (D).
- Once the mobile device is properly charging, the left LED on the back of the lamp will start blinking in blue for 1 O seconds then turn off.
PRODUCT SPECIFICATIONS
- Material: Glass I Aluminium/ ABS
- Weight: 430g / 0.95Ibs
- Dimensions: 013.5 x 29 cm 105.31 x 11.42″
- Max. lumen output: 150 Im
- Light power: 3 W
- Color temperature: 2800-5600K
- LED lifetime: 30000h
- Input port: 10W min (fN-2A) – 1 DOW max (20V-5A)
- Wireless charging output: Up to 15W*
- Output power: Up to 40W*
- Battery type: Li-ion 2000 mAh
- Battery voltage: 3. 7V
- Lamp on battery only: Up to 6 hours
- Charging system: USB Type-C
- Charging time (USB Type-C): 3 hours
- Operating temperature: 0°c -35°C
- Warranty: 1 year international*
*Wired & Wireless charging speeds can vary depending on the cable and power source being used.
EUROPEAN UNION
CE DIRECTIVE CE LEXON hereby declares that the device is in compliance with
the essential requirements and other relevant provisions of Directives RED
Directive 2014/53/EU
The original EU declaration of conformity may be found at: https://www.lexon-
design.com/assets/certifications-ce-bubblelamp.pdf
UK CONFORMITY ASSESSMENT
The object described above is in conformity with the essential requirements
and other relevant provisions of the UK Radio Equipment Regulations 2017 (SI
2017/1206).
This device was tested for uncontrolled environment operations. To comply with
RF exposure requirements, a minimum separation distance of 20cm must be
maintained between the user’s body and the product.
The original UK declaration of conformity may be found at: https://www.lexon-
design.com/assets/certifications-ukca-bubblelamp.pdf
Radiated H-Field: -13.81 dBuA/m(@10m) (for EU/ UK only)
TX/RX Frequency Range: 110-148 KHz (for EU/ UK only)
DISPOSAL AND RECYCLING INFORMATION
After the implementation of the European Directive 2012/19/EU in the national legal system, the following applies : electrical and electronic devices may not be disposed of with domestic waste. Consumers are obliged by law to return electrical and electronic device at the end of their service lives to the public collecting points set up for this purpose or point of sale. Details to this are defined by the national law of the respective country. This symbol on the product, the instruction manual or the package indicates that a product is subject to these regulations. By recycling, reusing the materials or other forms of utilizing old devices, you are making an important contribution to protecting our environment.
USA – FCC STATEMENT
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
- This device may not cause harmful interference, and
- This device must accept any interference received, including interference that may cause undesired operation.
Notice:
Any changes or modifications not expressly approved by the party responsible
for compliance could void your authority to operate the equipment.
NOTE: This equipment has been tested and found to comply with the limits for a
Class B digital device, pursuant to part 15 of the FCC Rules. These limits are
designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if
not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try
to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
- Consult the dealer or an experienced radio/ TV technician for help.
FCC RF exposure statement:
The equipment complies with FCC radiation exposure limits set forth for an
uncontrolled environment. This equipment should be installed and operated with
minimum distance between 20cm the radiator your body.
CANADA COMPLIANCE STATEMENT
This device complies with Industry Canada license-exempt RSSs. Operation is subject to the following two conditions:
- This device may not cause interference, and
- This device must accept any interference, including interference that may cause undesired operation of the device.
This Class B digital apparatus complies with Canadian ICES-001
RF exposure statement:
The equipment complies with IC Radiation exposure limit set forth for
uncontrolled environment. This equipment should be installed and operated with
minimum distance 10cm between the radiator and your body.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>