BEGA 33 294 Recessed Wall Luminaire Instruction Manual

June 21, 2024
BEGA

BEGA 33 294 Recessed Wall Luminaire

BEGA-33-294-Recessed-Wall-Luminaire-PRO

Product Information

Specifications

  • Application: Wall luminaire with unshielded light for flush or surface mounted installation
  • Light Output: Low for orientating lighting tasks
  • Rated Wattage: 1.9W – 2.3W
  • Colour Temperature: 3000K (Warm White) / 4000K (Cool White)
  • Colour Rendering Index (CRI): > 90
  • Luminous Flux: 285lm – 295lm
  • Luminous Efficiency: 29.1 lm/W – 30 lm/W
  • Voltage: 24V DC

Product Usage Instructions

Safety Precautions
The installation and operation of this luminaire must comply with national safety regulations. Only a qualified electrician should perform the installation and commissioning. The manufacturer is not liable for damage due to improper use or installation.

Installation Guidelines

  • Avoid contact with aggressive media as it can damage the luminaire housing.
  • Ensure the operating device meets EN 61347-2-13 requirements with a maximum idle voltage of 60V DC conforming to SELV or SELV equivalent.
  • Consider the ambient temperature, insulation, and voltage requirements during installation.

Maintenance and Cleaning
Avoid overuse of cleaning agents around the luminaire to prevent amage. If unsure about building material composition, conduct a material analysis before installation.

Accessories
Use appropriate power supply units for LED luminaires to ensure proper functionality and safety.

FAQ (Frequently Asked Questions)

  • Q: Can the luminaire be installed outdoors?
    A: This luminaire is designed for indoor use only. Outdoor installation may lead to damage due to exposure to environmental factors.

  • Q: What should I do if the luminaire is not functioning properly?
    A: Check the power supply unit, connections, and ensure proper voltage supply. If issues persist, contact a qualified electrician for assistance.

  • Q: Can I use a different operating device than specified in the manual?
    A: It is recommended to use an operating device that meets the requirements stated in the manual to avoid damage and ensure safe operation.

Application

  • Wall luminaire with unshielded light for flush or surface mounted installation.
  • With low light output for orientating lighting tasks.

Product Description

  • LED recessed luminaire without power supply unit Luminaire made of cast aluminium, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Colour graphite or silver
  • Safety glass, white
  • Silicone gasket
  • Required recessed opening 70 x 70 mm Recessed depth 80 mm
  • Fixing is achieved by using two adjustable wedge-shaped claws 1 cable entry for connecting cable max. ø 10,5 mm Connecting terminals 2.5@
  • Safety class III
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Safety mark
  • Impact strength IK05
  • Protection against mechanical
  • impacts < 0.7 joule
  •  – Conformity mark
  • Weight: 0.25 kg
  • This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Please note:
The luminaire must not have permanent contact with aggressive media. Aggressive media can be washed out of building materials and destroy the housing of the luminaire. In case of an unknown composition of the building materials, a material analysis is to be carried out before installation of the luminaire. Aggressive media that is outgoing from the surface might also affect the luminaire. Thus an overuse of cleaning agents in the surroundings of the luminaire must be avoided.

Please note:
The luminaire can only be operated with an operating device that fulfils the requirements according to EN 61347-2-13. The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.

Installation

The electrical connection must only be made to safety transformers according to EN 61558 – see accessories. The recessed opening will be covered by the frame of the luminaire housing. Fixing of the luminaire is achieved by using two adjustable wedge-shaped claws.

Installation in solid, plastered walls:
The installation housing 10 406 is available for this purpose. If this is not used, an exact recessed opening of 70 x 70 mm with a minimum depth of 80 mm is required.

Installation in exposed brickwork:
The construction of an on-site recessed opening with the exact installation dimensions of 70 x 70 mm with a minimum depth of 80 mm is required. An installation housing cannot be used.

Installation in drywalling:
A recessed opening of 70 x 70 mm with a minimum depth of 80 mm is required. The claws grip behind drywall.

Open luminaire:

  • Undo hexagon socket screws (SW 3) and remove housing cover.
  • Do not remove the desiccant pouch from the luminaire housing.
  • It is needed to remove residual moisture. Lead the secondary connecting cable supplied by others from the power supply unit through the cable entry into the luminaire housing. Make an electrical connection:
  • Connect black conductor with negative pole and red conductor with positive pole of the power supply unit.
  • A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the electrical connection of the luminaire – see accessories.
  • If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer.
  • Assemble housing cover. Make sure that gasket is positioned correctly. Tighten the screws evenly.
  • Insert luminaire housing into the recessed opening. Tighten screws of the claw fastener (torx drive T10) evenly.

Lamp

  • Module connected wattage 1.9 W
  • Luminaire connected wattage 2.3 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 65 °C
  • When installed in heat -insulating
  • material ta max = 55 °C
  • Voltage 24 V = DC

33 294 K3

  • Module designation LED-0312/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 285 lm
  • Luminaire luminous flux 67 lm
  • Luminaire luminous efficiency 29,1 lm / W

33 294 K4

  • Module designation LED-0312/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 295 lm
  • Luminaire luminous flux 69 lm
  • Luminaire luminous efficiency 30 lm / W

DIMENSION

BEGA-33-294-Recessed-Wall-Luminaire-1

Cleaning & Maintenance

  • Clean luminaire regularly with solvent-free leansers from dirt and deposits.
  • Do not use high pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire.

Accessories

Power supply unit for LED luminaires 24 V DC Safety transformer according to EN 61558/VDE 0570 part 2-6

  • 70 564 Power supply unit for 5-15 W

  • 70 465 Power supply unit for 10-25 W

  • 70 565 Power supply unit for 20-35 W

  • 70 566 Power supply unit for 30-50 W

  • 70 567 Power supply unit for 40-75 W

  • 70 169 Power supply unit for 70-150 W
    230 V 50-60 Hz

  • 71 134 Power supply unit for 0-70 W

    • AC range: AC: 198-264 V y 50-60 Hz
    • DC range: DC: 176-275 V

The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.

  • 10 406 Installation housing
  • 10 006 Plaster frame
  • 10 070 Plaster frame flush

For the accessories a separate instructions for use can be provided upon request.

Spares

  • LED module 3000 K LED-0312/930
  • LED module 4000 K LED-0311/940
  • Gasket 83 002 226

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals

Related Manuals