Specifications

  • Material: Aluminium alloy, Borosilicate glass, Aluminium, Stainless Steel
  • Power Supply: LED 220-240 V x 0/50-60 Hz DC 176-276 V
  • DALI Control: Yes (1 DALI address)
  • Insulation: Basic insulation for protection of temperature-sensitive components
  • Safety Class: Class I
  • Protection Class: IP 65

Product Usage Instructions

Installation :

  1. Ensure the mounting plate is securely attached to the luminaire.
  2. Connect the luminaire to the power supply following the provided specifications.
  3. If installing on unpaved surfaces, use the connection housing accessory for stability.

Operation:

The luminaire is designed for glare-free illumination of floor surfaces. It is suitable for lighting forecourts, gateways, and pathways in both private and public facilities.

Maintenance:

Regularly clean the luminaire to ensure optimal performance. Check for any loose connections or damage that may affect its functionality.

FAQ:

  • Q: Can the luminaire be controlled remotely?
    A: Yes, the luminaire is DALI-controllable, allowing for remote operation.

  • Q: What is the expected service life of the LED module?
    A: The LED module has a service life of approximately 50,000 hours at L70 criteria.

Instructions for use

Application

  • Luminaire for glare-free illumination of floor surfaces from an extremely low mounting height.
  • For the illumination of forecourts, gateways and ways in private and public facilities.
  • For the various requirements at the installation site, we offer a connection housing as an accessory.
  • The luminaires can thus be installed on unpaved surfaces.

Product Description

  • Luminaire made of aluminum alloy,
  • aluminum and stainless steel
  • BEGA Tricoat® coating technology
  • Color graphite or silver
  • Borosilicate glass
  • The reflector surface made of pure aluminum
  • Luminaire with mounting plate for bolting onto a foundation or onto a connecting housing
  • 3 fixing holes ø 8.5 mm
  • Angle 120° · Pitch circle ø 100 mm
  • 1,8 m water-resistant connecting cable
  • 07RN8-F 5 G 1@ with implemented water
  • stopper and 1.2 m PVC cable conduit
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 176-276 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without
  • switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • c – Conformity mark
  • This product contains light sources of energy efficiency class(es) C

Lamp

  • Module connected wattage 13.2 W
  • Luminaire connected wattage 15.5 W
  • Rated temperature ta = 25 °C
  • Service life criteria 50 000 h / L70

85 222 K3

  • Module designation LED-1288/830
  • Colour temperature 3000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2420 lm
  • Luminaire luminous flux * 800 lm
  • Luminaire luminous efficiency * 51,6 lm / W

85 222 K4

  • Module designation LED-1288/840
  • Colour temperature 4000 K
  • Colour rendering index CRI > 80
  • Module luminous flux 2490 lm
  • Luminaire luminous flux * 823 lm
  • Luminaire luminous efficiency * 53,1 lm / W

preliminary data

DIMENSION

BEGA-85-222-Surface-Mounted-Luminaire-FIG- \(1\)

Lighting technology

Luminaire data for the DIALux lighting design program for outdoor lighting, street lighting and indoor lighting, as well as luminaire data in EULUMDAT and IES format are available on the BEGA website at www.bega.com.

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

  • The base of the luminaire must not be below the upper edge of the floor covering.
  • Undo the hexagon socket screw (wrench size 3 mm) through the opening in the luminaire housing up to the stop.
  • Remove the mounting plate from the luminaire housing.
  • Installation on foundations provided by the customer or on other paved surfaces (ill. A):BEGA-85-222-Surface-Mounted-Luminaire-FIG- \(2\)

For the electrical connection and for accepting the connecting cable with water stopper a cavity of ø 35 mm is required under the luminaire at site.

  • Sufficient drainage must be provided.
  • If the luminaire connecting cable is laid in the soil the enclosed protective conduit must be used.
  • Fix the mounting plate with enclosed or any other suitable fixing material onto the foundation.

Installation onto a connection housing (ill. B):

  • Fix mounting plate onto the connection housing (BEGA accessory 71 246).
  • The electrical connection must be carried out with matching protection class and safety class with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
  • We recommend the use of distribution box 70 730.
  • To protect the luminaire connecting cable from damage push the enclosed cable conduit over the cable.
  • Make the earth conductor connection and the electrical connection.
  • Note correct configuration of the mains supply cable. Make mains supply connection at the brown (L), blue (N) and green-yellow lead (1).
  • The connection of the control cables is achieved using both leads marked with DALI.
  • In case these leads are not used the luminaire will be operated at full light output.
  • Place luminaire housing onto the mounting plate, aligns and tighten.

Please note:

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture

Cleaning/Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Close the luminaire.

Accessories

  • 71 246 Connection housing made of galvanised steel Total length 225 mm
  • 70 730 Distribution box with 7 cable entries Connection terminals 5 x 4
  • For the accessories separate instructions for use can be provided upon request.

Spares

  • Spare glass 11 003 650 B1
  • LED power supply unit DEV-0312/350
  • LED module 3000 K LED-1288/830
  • LED module 4000 K LED-1288/840
  • Reflector 76 002 146
  • Gasket housing bottom 83 001 953
  • Gasket glass 83 002 315