BEGA 85122 Compact Floodlight Instruction Manual
- June 20, 2024
- BEGA
Table of Contents
06.23 Technical amendments reserved
Compact floodlight
85 122
IP 65
Instructions for use
Application
Compact floodlight for installation on BEGA profile poles with profile groove.
Product description Luminaire made of aluminium alloy, aluminium and stainless
steel BEGA Unidure ® coating technology Colour graphite or silver BEGA Hybrid
Optics ® Clear safety glass Reflector surface made of pure aluminium
Rotation range of floodlight 350° Swivel range -15°/+130°
Connecting cable X05BQ-F 5 G 1 mm² Cable length 1 m
BEGA Ultimate Driver ® Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1 LED power supply unit
220-240 V x 0/50-60 Hz DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control ® Temporary thermal regulation to protect temperature-
sensitive components without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical impacts < 2 joule
** – Conformity mark
This product contains light sources of energy efficiency class(es) E
Light technique**
Broad spread light distribution.
Half beam angle 45°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
The ideal protection of all electronic components installed in the luminaires
is achieved by using bounce-free switching contacts such as an electronic
relay (solid-state relay), e.g. BEGA 71 320.
Installation
Loosen the hexagon socket screws (wrench size 5 mm) at the pole head and lift
out the connection box (see sketch 1, 2).
Insert the floodlight into the profile groove on the profile pole and fix it
in the desired position using both hexagon socket screws (wrench size 4 mm)
(see sketch 3).
Route the connecting cable for the floodlight into the pole through the
closest slotted hole in the profile groove (see sketch 4).
The electrical connection is made in the connection box in the pole head.
Guide the floodlight connecting cable through the cable gland into the
connection box.
Tighten the screw cable gland. Make the earth conductor connection and the
electrical connection.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow (1), the phase to the brown (L), and the neutral
conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Place the connection box on the profile pole and secure it in place.
Make sure that gasket is positioned correctly. Tighten the screws uniformly in
crosswise fashion. Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch 5, 6).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screws (wrench size 2 mm).
Lamp
Module connected wattage | 24.1 W |
---|---|
Luminaire connected wattage | 26.8 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 45 °C |
85 122 K3
Module designation| LED-0800/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 3350 lm
Luminaire luminous flux| 2472 lm
Luminaire luminous efficiency| 92,2 lm / W
85 122 K4
Module designation| LED-0800/940
Colour temperature| 4000 K
Colour rendering index| CRI > 90
Module luminous flux| 3400 lm
Luminaire luminous flux| 2509 lm
Luminaire luminous efficiency| 93,6 lm / W
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim
ring.
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
71 280 Shield
71 285 Cylindrical shield
71 290 Optical filter flat beam
For this luminaire we recommend the following BEGA luminaire poles:
Profile poles made of lacquered aluminium
84 700 square | H 4000 mm |
---|---|
84 701 square | H 6000 mm |
84 702 round | H 4000 mm |
84 703 round | H 6000 mm |
Profile poles with glued laminated wood in accordance with DIN EN 14 080
84 696 square | H 4000 mm |
---|---|
84 697 square | H 6000 mm |
84 698 round | H 4000 mm |
84 703 round | H 6000 mm |
For the accessories a separate instructions for use can be provided upon
request.
Spares
Trim ring graphite wih glass | 25 000 234 |
---|---|
Trim ring silver with glass | 25 000 235 |
LED power supply unit | DEV-0353/700 |
LED module 3000 K | LED-0800/930 |
LED module 4000 K | LED-0800/940 |
Gasket housing | 83 002 022 |
Gasket trim ring | 83 002 222 |
BEGA Gantenbrink-Leuchten KG · Postfach 31 60
58689 Menden
info@bega.com
www.bega.com
Documents / Resources
| BEGA
85122 Compact
Floodlight
[pdf] Instruction Manual
85122, 71320, 85122 Compact Floodlight, 85122, Compact Floodlight, Floodlight
---|---
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>