BEGA 50039K27 Wall and Ceiling Light Instruction Manual

June 17, 2024
BEGA

06.24 · Technical amendments reserved

50 039

Ceiling and wall luminaire for indoor use

Instructions for use

Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass and metal housing, for all lighting tasks. They are ideal for places where a soft and uniform lighting distribution is required.
Luminaire with motion sensor.

Product description
Metal housing, finish colour white
Hand-blown opal glass, satin matt, with bayonet closure
Integrated HF-motion sensor, maximum range 10 m
2 mounting holes ø 5.5 mm Distance apart 180 mm 2 cable entries for through- wiring for mains cable up to ø 10.5 mm max. 3 × 1.5
Connection terminal 2.5
Earth conductor connection
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V ∼ 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
-­ Conformity mark
Weight: 1.7 kg
This product contains light sources of energy efficiency class(es) D, E

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp
Module connected wattage           8.2 W
Luminaire connected wattage      10.5 W
Rated temperature                   ta = 25 °C
Ambient temperature        ta max = 40 °C

50 039 K27
Colour temperature                         2700 K
Colour rendering index                  CRI >90
Module luminous flux                      1165 lm
Luminaire luminous flux                    648 lm
Luminaire luminous efficiency     61,7 lm/W

50 039 K3
Colour temperature                       3000 K
Colour rendering index                CRI >90
Module luminous flux                   1205 lm
Luminaire luminous flux                 671 lm
Luminaire luminous efficiency   63,9 lm/W

50 039 K4
Colour temperature                          4000 K
Colour rendering index                   CRI >90
Module luminous flux                      1255 lm
Luminaire luminous flux                    699 lm
Luminaire luminous efficiency      66,6 lm/W

Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be inserted into the trim ring (accessory).

Installation
LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.

Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Make earth and electrical connection to the terminals.
Place glass to the luminaire housing and observe that the cam pins fit into the notches of the glass.
Screw in glass by turning it clockwise.
Thus, you reach a safe and vibration-resistant holding of the glass.

To release the glass from the luminaire housing, turn it counter-clockwise.

  1.  LED indicator
  2. Daylight sensor

HF-motion sensor

Detection area
Dwell time
Daylight threshold

The built-in motion sensor operates at a frequency of 5.8 GHz.
Detection range: 30° to 150°.
Operating temperature: -35° C to +70° C.
With a wall mounting height of 1.8 m or ceiling mounting height of 2.6 m, the maximum range is 9 / 10 meters (see sketch).

Wall                                         Ceiling

Detection range

The max. wall mounting height is 4.0 m and the max. ceiling mounting height is 6.0 m, in which the range reduces significantly.

Note: The installation distance between 2 luminaires with HF motion sensors should be more than 2 metres to prevent the sensors from being triggered incorrectly. Local conditions can affect both the range and the detection area.

Detection Range

DIP Switch Settings

Setting of Sensitivity / Range

on    off
1    2  3

| 1| 2| 3|
---|---|---|---|---
I | | | | 100%
II| | | | 75%
III | | | | 50%
IV| | | | 25%
V| | | | 10%

Detection Range
The sensor sensitivity (10% to 100%) can be precisely set for each specific application by selecting the combination on DIP switches 1-3.

Please note that a reduction in sensitivity also leads to a reduction in the range.

Dwell time
DIP Switch Settings

Setting of dwell time

on    off
1   2  3  4

| 1| 2| 3| 4|
---|---|---|---|---|---
I | | | | | 5 s
II| | | | | 30 s
III | | | | | 1 min
IV| | | | | 5 min
V| | | | | 15 min
VI| | | | | 30 min

Dwell time
By moving within the detection range the motion sensor switches on the LED module inside the luminaire with a defined dwell time. Select the DIP switch position 1-4 for the light switch-on time (5 s to 30 min.) after presence detection.
This function is deactivated if natural daylight is sufficient (exception: the threshold is deactivated).

Daylight treshold
DIP Switch Settings

Setting of brightness

on    off
1   2  3  4

| 1| 2| 3| 4|
---|---|---|---|---|---
I | | | | | 2 Lux
II| | | | | 5 Lux
III | | | | | 10 Lux
IV| | | | | 30 Lux
V| | | | | 50 Lux
VI| | | | | Deaktiv.

Daylight threshold
Use DIP switches 1-4 to set the sensor level according to the lighting and the surroundings. The light does not switch on if the ambient brightness exceeds the set daylight threshold. Please note that the ambient brightness refers to the internal light that reaches the sensor. If you deactivate the daylight sensor, the sensor switches to “Presence detection only” mode.

To set the luminaire to switch on and off automatically when it is dark or light outside, follow these steps:
A. Quick switch on and off:
You can switch the luminaire on and off quickly by simply pressing the switch (light switch) twice. The green LED indicator on the HF sensor flashes slowly for 5 seconds and the luminaire flashes twice.
B. Measurement of daylight:
The sensor measures the brightness of the surroundings for 1 second and stores this information.
C. Confirmation:
The luminaire is then in operation and the green LED indicator lights up for 10 seconds to indicate that the setting was successful.
Thanks to this function, the luminaire can work well even if the daylight outside varies greatly. It is important to note that the last measured ambient light value always replaces the previous value. In addition, both the setting on the switch and the measured brightness value can replace each other.
The last action that was carried out remains valid.

Note: You can display the DIP switch settings via smartphone or tablet by scanning the QR code on the housing of the HF sensor.

Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to those of the LED units originally fitted. The LED unit can be replaced by qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Replace the LED unit.
Screw in glass by turning it clockwise.
Defective glass must be replaced.

Accessory · Trim rings

For this luminaire metal trim rings in 3 enamel surfaces are optional available.
Trim rings are accessories and must be ordered separately.

Item                             Part. No
Colour white                 13 001
Colour palladium         13 002
Colour glossy silver       13 003

Spares

Spare glass                        11 003 179 .0R G
HF-motion sensor             61 002 191
LED unit 2700 K              75 003 045 K27
LED unit 3000 K              75 003 045 K3
LED unit 4000 K               75 003 045 K4

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden • info@bega.comwww.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals