50 039
Ceiling and wall luminaire for indoor use
Instructions for use
Application
Ceiling and wall luminaire · indoor luminaire made of hand-blown opal glass
and metal housing, for all lighting tasks. They are ideal for places where a
soft and uniform lighting distribution is required.
Luminaire with motion sensor.
Product description
Metal housing, finish colour white
Hand-blown opal glass, satin matt, with bayonet closure
Integrated HF-motion sensor, maximum range 10 m
2 mounting holes ø 5.5 mm Distance apart 180 mm 2 cable entries for through-
wiring for mains cable up to ø 10.5 mm max. 3 × 1.5
Connection terminal 2.5
Earth conductor connection
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR
63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V ∼ 50/60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
- Conformity mark
Weight: 1.7 kg
This product contains light sources of energy efficiency class(es) D, E
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp
Module connected wattage 8.2 W
Luminaire connected wattage 10.5 W
Rated temperature ta = 25 °C
Ambient temperature ta max = 40 °C
50 039 K27
Colour temperature 2700 K
Colour rendering index CRI >90
Module luminous flux 1165 lm
Luminaire luminous flux 648 lm
Luminaire luminous efficiency 61,7 lm/W
50 039 K3
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 1205 lm
Luminaire luminous flux 671 lm
Luminaire luminous efficiency 63,9 lm/W
50 039 K4
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 1255 lm
Luminaire luminous flux 699 lm
Luminaire luminous efficiency 66,6 lm/W
Luminaire with trim ring:
Before installing onto the mounting surface the luminaire housing must be
inserted into the trim ring (accessory).
Installation
LED are high-quality electronic components! Please avoid touching the light
output opening of the LED directly during installation or relamping.
Pass the mains supply cable through the grommet into luminaire housing.
Fix luminaire housing with enclosed or any other suitable fixing material on
to the mounting surface.
It is imperative to use the enclosed gaskets.
Dismantle the mains supply cable approx. 60 mm.
Make earth and electrical connection to the terminals.
Place glass to the luminaire housing and observe that the cam pins fit into
the notches of the glass.
Screw in glass by turning it clockwise.
Thus, you reach a safe and vibration-resistant holding of the glass.
To release the glass from the luminaire housing, turn it counter-clockwise.
- LED indicator
- Daylight sensor
HF-motion sensor
Detection area
Dwell time
Daylight threshold
The built-in motion sensor operates at a frequency of 5.8 GHz.
Detection range: 30° to 150°.
Operating temperature: -35° C to +70° C.
With a wall mounting height of 1.8 m or ceiling mounting height of 2.6 m, the
maximum range is 9 / 10 meters (see sketch).
Wall Ceiling
Detection range
The max. wall mounting height is 4.0 m and the max. ceiling mounting height is 6.0 m, in which the range reduces significantly.
Note: The installation distance between 2 luminaires with HF motion sensors should be more than 2 metres to prevent the sensors from being triggered incorrectly. Local conditions can affect both the range and the detection area.
Detection Range
DIP Switch Settings
Setting of Sensitivity / Range
on off
1 2 3
| 1| 2| 3|
---|---|---|---|---
I | | | | 100%
II| | | | 75%
III | | | | 50%
IV| | | | 25%
V| | | | 10%
Detection Range
The sensor sensitivity (10% to 100%) can be precisely set for each specific
application by selecting the combination on DIP switches 1-3.
Please note that a reduction in sensitivity also leads to a reduction in the range.
Dwell time
DIP Switch Settings
Setting of dwell time
on off
1 2 3 4
| 1| 2| 3| 4|
---|---|---|---|---|---
I | | | | | 5 s
II| | | | | 30 s
III | | | | | 1 min
IV| | | | | 5 min
V| | | | | 15 min
VI| | | | | 30 min
Dwell time
By moving within the detection range the motion sensor switches on the LED
module inside the luminaire with a defined dwell time. Select the DIP switch
position 1-4 for the light switch-on time (5 s to 30 min.) after presence
detection.
This function is deactivated if natural daylight is sufficient (exception: the
threshold is deactivated).
Daylight treshold
DIP Switch Settings
Setting of brightness
on off
1 2 3 4
| 1| 2| 3| 4|
---|---|---|---|---|---
I | | | | | 2 Lux
II| | | | | 5 Lux
III | | | | | 10 Lux
IV| | | | | 30 Lux
V| | | | | 50 Lux
VI| | | | | Deaktiv.
Daylight threshold
Use DIP switches 1-4 to set the sensor level according to the lighting and the
surroundings. The light does not switch on if the ambient brightness exceeds
the set daylight threshold. Please note that the ambient brightness refers to
the internal light that reaches the sensor. If you deactivate the daylight
sensor, the sensor switches to “Presence detection only” mode.
To set the luminaire to switch on and off automatically when it is dark or
light outside, follow these steps:
A. Quick switch on and off:
You can switch the luminaire on and off quickly by simply pressing the switch
(light switch) twice. The green LED indicator on the HF sensor flashes slowly
for 5 seconds and the luminaire flashes twice.
B. Measurement of daylight:
The sensor measures the brightness of the surroundings for 1 second and stores
this information.
C. Confirmation:
The luminaire is then in operation and the green LED indicator lights up for
10 seconds to indicate that the setting was successful.
Thanks to this function, the luminaire can work well even if the daylight
outside varies greatly. It is important to note that the last measured ambient
light value always replaces the previous value. In addition, both the setting
on the switch and the measured brightness value can replace each other.
The last action that was carried out remains valid.
Note: You can display the DIP switch settings via smartphone or tablet by scanning the QR code on the housing of the HF sensor.
Replacement of the LED unit
The designation of the LED unit is noted on a label in the luminaire.
The light colour and light output of BEGA replacement units correspond to
those of the LED units originally fitted. The LED unit can be replaced by
qualified persons using standard tools.
Disconnect from main supply.
Unscrew glass from luminaire housing by turning it counter-clockwise.
Replace the LED unit.
Screw in glass by turning it clockwise.
Defective glass must be replaced.
Accessory · Trim rings
For this luminaire metal trim rings in 3 enamel surfaces are optional
available.
Trim rings are accessories and must be ordered separately.
Item Part. No
Colour white 13 001
Colour palladium 13 002
Colour glossy silver 13 003
Spares
Spare glass 11 003 179 .0R G
HF-motion sensor 61 002 191
LED unit 2700 K 75 003 045 K27
LED unit 3000 K 75 003 045 K3
LED unit 4000 K 75 003 045 K4
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden • info@bega.com • www.bega.com