Product Information

Specifications

  • Model: Leistungsscheinwerfer Performance Floodlight
  • Connected Wattage: 36.8 W – 40 W
  • Color Temperature: 3000 K – 4000 K
  • Colour Rendering Index (CRI): > 90
  • Luminous Flux: 5145 lm – 5220 lm
  • Luminous Efficiency: 95.8 lm/W – 97.2 lm/W

Product Usage Instructions

  • The installation and operation of this luminaire must comply with national safety regulations.
  • Installation and commissioning should only be performed by a qualified electrician.
  • The manufacturer does not accept liability for damage due to improper use or installation.
  • Any modifications must be done by authorized personnel.

FAQ

  • Q: Can I replace the connecting cable myself?
  • A: No, the connecting cable should only be replaced by a qualified electrician to ensure safety.
  • Q: Is it necessary to keep the desiccant bag inside the luminaire?
  • A: Yes, the desiccant bag should not be removed as it helps in removing residual moisture.

Dimension

Instructions for use

Application

  • Performance floodlight with G½ mounting bush.
  • The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories.
  • For a variety of interior and exterior lighting applications.

Product Description

  • Luminaire made of aluminum alloy, aluminum, and stainless steel
  • BEGA Unidure® coating technology
  • Color graphite or silver Clear safety glass Silicone gasket
  • Reflector surface made of pure aluminum BEGA Hybrid Optics®
  • The rotation range of floodlight 350° Swivel range -30°/+95°
  • Mounting bracket with G½ threaded connection
  • Thread length: 14 mm
  • Connecting cable X05BQ-F 5 G 1 mm² Cable length 1 m
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control®
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  •  – Conformity mark
  • Wind catching area: 0.028 m²
  • Weight: 2.8 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage under DIN EN 61547.
  • To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at  www.bega.com.
  • The ideal protection of all electronic components installed in the luminaires is achieved by using bounce-free switching contacts such as an electronic relay (solid-state relay), e.g. BEGA 71 320.

Installation

  • Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
  • G½ threaded connection torque = 40 Nm.
  • Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A ).
  • Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.

Adjust floodlight

  • Undo the hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch B, C ).

Torque:

  • Hexagon socket screw = 7 Nm

  • Hexagon nut = 35 Nm

  • Secure bolted connection Gß against loosening by tightening the hexagon socket screws (wrench size 2 mm).

  • The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.

  • Note the correct configuration of the main supply cable. The earth conductor is connected at the green-yellow ( ), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire.

  • The connection of the control cables is achieved through both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.

Lamp

  • Module connected wattage 36.8 W
  • Luminaire connected wattage 40 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 40 °C

85 161 K3

  • Module designation LED-0780/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 5145 lm
  • Luminaire luminous flux 3834 lm
  • Luminaire luminous efficiency 95,8 lm / W

85 161 K4

  • Module designation LED-0780/940
  • Color temperature 4000 K
  • Color rendering index CRI > 90
  • Module luminous flux 5220 lm
  • Luminaire luminous flux 3890 lm
  • Luminaire luminous efficiency 97,2 lm / W

Lighting technology

  • Symmetrical wide beam light distribution
  • Half beam angle 54°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Cleaning And Maintenance

  • Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
  • Do not use high-pressure cleaners.

Maintenance

  • The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Please note

  • Do not remove the desiccant bag from the luminaire housing.
  • It is needed to remove residual moisture.

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Open the floodlight:
  • Undo the locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
  • Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
  • Replace the LED module.
  • Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • The defective glass must be replaced.
  • Place the trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top of each other.
  • Twist on the trim ring clockwise as far as the stop. Tighten the locking pin.

Accessories

  • 71 291 Optical filter flat beam
  • 71 333 Shield
  • 71 338 Cylindrical shield
  • 70 214 Pole cap for pole ø 48 mm
  • 70 248 Pole cap for pole ø 60 mm
  • 70 245 Mounting box
  • 70 252 General fastener
  • 70 280 Tube clamp G½
  • 70 283 Screw clamp
  • 70 379 Crossbeam G½
  • 70 889 Tension belt

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 281
  • Trim ring silver with glass 25 000 282
  • LED power supply unit DEV-0270/1050i
  • LED module 3000 K LED-0780/930
  • LED module 4000 K LED-0780/940
  • Reflector 75 005 099
  • Gasket housing 83 001 579
  • Gasket trim ring 83 002 306

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals