Performance floodlight BEGA UniLink®
Technical amendments reserved
84 489
IP 65
Instructions for use
Application
Performance floodlight BEGA UniLink® with earth spike and 5 m connecting cable
with plug connector.
A separate mains plug must be ordered in order to connect the floodlight to
the mains.
The various country-specific mains plugs with 0.5 m connecting cable, as well
as extension cables and five-way distribution boxes are available as
accessories.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Earth spike made of glass fibre reinforced synthetic
material Clear safety glass
Reflector surface made of pure aluminium Optical silicone lens · BEGA Hybrid
Optics®
Swivel range -80°/+90°
5 m mains supply cable
X05RN-F FEP 2 × 1@ + 1G2,5@ with plug-in connector
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V 50-60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical impacts < 5 joule
– Conformity mark
Weight: 2.2 kg
This product contains light sources of energy efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Total load
When configuring your lighting system, please ensure that the maximum power
consumption of 6 A is not exceeded. Information on power consumption can be
found in the instructions for use and data sheets for all BEGA UniLink®
luminaires.
Power consumption of 84 489: 0,1 A
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Lamp|
---|---
Module connected wattage| 16.8 W
Luminaire connected wattage| 19.3 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 40 °C
84 489 K3|
Module designation| LED-0800/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 2440 lm
Luminaire luminous flux| 1911 lm
Luminaire luminous efficiency| 99 lm / W
84 489 K4|
Module designation| LED-0800/940
Colour temperature| 4000 K
Colour rendering index| CRI > 90
Module luminous flux| 2480 lm
Luminaire luminous flux| 1942 lm
Luminaire luminous efficiency| 100,6 lm / W
Light technique
Symmetrical wide beam light distribution Half beam angle 46°
For special lighting applications, the symmetrical light cone can be changed
to a flat beam using an additional diffuser lens.
Caution:
The BEGA UniLink® plug connectors may only be connected and disconnected in a
voltagefree state.
Installation
Press the luminaire with earth spike vertically into the soil until stability
is achieved. If necessary, compact soil around the earth spike.
Plug the floodlight’s connecting cable into the plug contact of the connecting
cable with the country-specific mains plug, or into the distribution box or
extension cable.
To ensure a sufficiently low protective conductor resistance (loop
resistance), the connecting cable of each luminaire in the system must not
exceed a length of 50 m from the entry point.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 7 Nm.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be
replaced by a qualified electrician.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counterclockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop.
Tighten locking pin.
Accessories
71 118 Shield
71 120 Exchangeable lens flat beam
0.5 m connecting cable with country-specific mains plugs
71 180 | Plug type F / E: system common in Germany and Europe |
---|---|
71 181 | Plug type G: system used in Great Britain (“Commonwealth plug”) |
71 182 | Plug type J: system common in Switzerland and Liechtenstein |
71 183 | Plug type L: system common in Italy and Greece |
71 184 | Plug type K: system common in Denmark and Greenland |
71 186 | BEGA UniLink® Extension cable 5 m |
71 187 | BEGA UniLink® Extension cable 10 m |
71 188 | BEGA UniLink® Extension cable 20 m |
71 247 | Connecting cable 5 m with free line ends |
71 256 | Connecting cable 0.5 m with free line ends |
71 189 | BEGA UniLink® Five-way distribution box |
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass with frame with glass 25 000 097
LED power supply unit DEV-0341/500
LED module 3000 K LED-0800/930
Reflector 76 001 853
Gasket housing 83 000 521
Gasket trim ring 83 001 952