BEGA 84940 Compact Flood Light Rgbw Instruction Manual
- June 11, 2024
- BEGA
Table of Contents
BEGA 84940 Compact Flood Light Rgbw
DIMENSION
Specifications
- Lamp Module connected wattage: 20.8 W
- Luminaire connected wattage: 24 W
- Module designation: LED-1161/RGBW
- The colour temperature of the white LED: is 4000 K
- Luminaire luminous flux: 1288 lm
- Luminaire luminous efficiency: 53.7 lm/W
Instructions for use
Application
- Compact floodlights with G½ connecting thread.
- The floodlight can be screwed on by the customer with any G½ female thread according to ISO 228 or with BEGA accessories.
- The floodlight can be controlled by DALI colour light control.
Product Description
- Luminaire made of aluminium alloy, aluminium and stainless steel
- BEGA Unidure® coating technology
- Clear safety glass
- Reflector surface made of pure aluminium Rotation range of floodlight 350°
- Swivel range -15°/+130°
- Mounting bracket with G½ threaded connection
- Thread length: 11 mm
- Connecting cable X05BQ-F 5 G 1 mm²
- Cable length 1 m
- BEGA Ultimate Driver®
- Complies with flicker requirements per IEEE 1789,
- DIN IEC/TR 63158, DIN IEC/TR 61547-1
- LED power supply unit
- 220-240 V 0/50-60 Hz
- DC 176-264 V
- DALI-controllable
- Number of DALI addresses: 1
- Basic insulation is provided between the mains and control cables
- BEGA Thermal Control®
- Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
- Safety class I
- Protection class IP 65
- Dust-tight and protection against water jets Impact strength IK08
- Protection against mechanical
- impacts < 5 joule
- Safety mark
- CE – Conformity mark
- Wind catching area: 0.02 m²
- Weight: 2.0 kg
- This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations. Installation and commissioning may only be carried out by
a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to
the luminaire, the person responsible for these modifications shall be
considered the manufacturer.
Overvoltage protection
- The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
- To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
- You can find them on our website at: www.bega.com.
Installation
- Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory.
- G½ threaded connection torque = 40 Nm. Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A).
- Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.
Adjust floodlight:
Undo the hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size
30 mm) and set the desired beam direction.
Torque:
- Hexagon socket screw = 7 Nm
- Hexagon nut = 35 Nm
- Secure bolted connection Gß against loosening by tightening the hexagon socket screw (wrench size 2 mm) (see sketch B, C).
- The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable.
- Note the correct configuration of the main supply cable.
- Make mains supply connection at the brown (L), blue (N) and green-yellow lead ( ).
- The connection of the control cables is achieved using both leads marked with DALI.
- In case these leads are not used the luminaire will be operated at full light output.
SPECIFICATION
Lamp
- Module connected wattage 20.8 W
- Luminaire connected wattage 24 W
- Rated temperature ta = 25 °C
- Ambient temperature ta max = 35 °C
- Module designation LED -1161/RGBW
- The colour temperature of the white LED 4000 K
- Luminaire luminous flux 1288 lm
- Luminaire luminous efficiency 53,7 lm / W
Lighting technology
- Wide beam light distribution
- Half beam angle 24°
- For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.
Cleaning · Maintenance
- Clean the luminaire regularly with solvent-free cleansers from dirt and deposits.
- Do not use high-pressure cleaners.
Replacing the LED module
- The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
- The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
- Disconnect the system from the power supply.
- Open the floodlight:
- Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim ring.
- Remove the trim ring along with the safety glass and reflector by twisting it anti-clockwise.
- Replace the LED module.
- Please follow the installation instructions for the
- LED module.
- Inspect and, if necessary, replace the luminaire gaskets.
- The defective glass must be replaced.
- Place the trim ring with glass and reflector on the floodlight housing so that the notches in the trim ring and luminaire housing sit on top of each other.
- Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
- 71 280 Shield
- 71 285 Cylindrical shield
- 71 290 Optical filter flat beam
- 71 042 Adapter for installation on a pole 70 214 Pole cap for pole ø 48 mm
- 70 248 Pole cap for pole ø 60 mm
- 70 245 Mounting box
- 70 252 General fastener
- 70 280 Tube clamp G½
- 70 283 Screw clamp
- 70 379 Crossbeam G½
- 70 889 Tension belt
For the accessories, separate instructions for use can be provided upon request.
Spares
- LED cover 15 000 494
- LED power supply unit DEV-0418/200i
- LED module LED-1161/RGBW
- Reflector 76 002 013
- Gasket housing 83 002 022
- Gasket Abschlussring 83 002 222
CONTACT
- BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden
- info@bega.com
- www.bega.com
FAQ
- Q: Can I install the luminaire myself?
- A: No, the installation and commissioning should only be performed by a qualified electrician to ensure safety and proper functioning.
- Q: Where can I find additional accessories for the product?
- A: Additional accessories can be obtained by requesting a separate instructions manual or visiting the manufacturer’s website for more information.
References
Read User Manual Online (PDF format)