Application
Recessed wall luminaire with shielded light distribution.
For indicating danger points and traffic areas.

Dark Sky
The light of this luminaire is directed evenly and highly efficiently onto the surface to be illuminated. No light is emitted into the upper half-space of the luminaire.

Product Description

  • LED recessed luminaire without power supply unit
  • Luminaire made of cast aluminium, aluminium and stainless steel
  • BEGA Unidure® coating technology
  • Matt safety glass
  • Silicone gasket
  • Recessed opening ø 71 mm
  • Required installation depth 90 mm
  • Fixing is achieved by using two adjustable wedge-shaped claws
  • 1 cable entry for mains supply cable up to ø 10,5 mm
  • Connecting terminals 2.5@
  • Safety class III 3
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • r – Safety mark
  • Impact strength IK05
  • Protection against mechanical impacts < 0.7 joule
  • c – Conformity mark
  • Weight: 0.25 kg

This product contains light sources of energy efficiency class(es) D

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Please note: The luminaire must not have permanently contact with aggressive media.
Aggressive media can be washed out of building materials and destroy the housing of the luminaire. In case of an unknown composition of the building materials a material analysis is to be carried out before installation of the luminaire. Aggressive media that is
outgoing from the surface might also affect the luminaire. Thus an overuse of cleaning agents in the surroundings of the luminaire must be avoided.

Installation

The electrical connection must only be made to safety transformers according to EN 61558 – see accessories.
LED are high-quality electronic components!

Please avoid touching the light output opening of the LED directly during installation or relamping.

The recessed opening is covered by the frame of the luminaire housing.
Fixing of the luminaire in the structure is achieved by using two adjustable wedge-shaped claws.

Installation into solid walls:
For this purpose installation housing 10 415 is available. If the installation housing cannot be used a recessed opening ø 71 mm is necessary to accept the luminaire housing.
Recessed depth min. 90 mm.

Installation into wall panels

A recessed opening of ø 71 mm is necessary to accept the luminaire housing. Recessed depth min. 90 mm. The lateral distance between recessed luminaire and other building parts must be at least 50 mm. The claws catch the wall panel from the back side.

  • Minimum thickness of the wall panel is 4 mm.
  • If the wall panel has a thickness of less than 4 mm, the panel thickness must be increased from the back side.
  • Undo screws.
  • Remove front plate with glass and gasket.
  • Disassemble tray for electrical equipment.
  • Do not remove the desiccant pouch from the luminaire housing.
  • It is needed to remove residual moisture.
  • Lead the secondary connecting cable supplied by others from the power supply unit through the cable entry into the luminaire housing.
  • Make electrical connection:
  • Connect black conductor with negative pole and red conductor with positive pole of the power supply unit.
  • A 24 V safety direct voltage source with a smoothed residual ripple of max. 10 % is required for the electrical connection of the luminaire – see accessories.
  • If other safety direct voltage sources are used, an upstream fuse (max. 6 A) must be provided by the customer.
  • Assemble tray for electrical equipment.
  • Push luminaire housing into the recessed opening.
  • Tighten screws of claw fastener.
  • Place glass with gasket onto the luminaire housing so that the matt surface is inside the housing.
  • Assemble front plate.

Please note:
The luminaire can only be operated with an operating device that fulfills the requirements according to EN 61347-2-13.
The maximum idle voltage of 60 V DC must conform to SELV or SELV equivalent.

Lamp

  • Module connected wattage                                        1.9 W
  • Luminaire connected wattage                                     2.3 W
  • Rated temperature                                                        ta = 25 °C
  • Ambient temperature                                                    ta max = 60 °C
  • When installed in heat-insulating material              ta max = 50 °C
  • Voltage                                                                            24 V = DC

22 101 K3

  • Module designation                  LED-0312/930
  • Colour temperature                              3000 K
  • Colour rendering index                       CRI > 90
  • Module luminous flux                           285 lm
  • Luminaire luminous flux                           9 lm
  • Luminaire luminous efficiency        3,9 lm / W

22 101 K4

  • Module designation                           LED-0312/940
  • Colour temperature                           4000 K
  • Colour rendering index                     CRI > 90
  • Module luminous flux                       295 lm
  • Luminaire luminous flux                  9 lm
  • Luminaire luminous efficiency          3,9 lm / W

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The module can be replaced by qualified persons using standard tools.
  • Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.
  • Inspect and, if necessary, replace the luminaire gaskets.
  • Defective glass must be replaced.
  • Close the luminaire

Accessories

Power supply unit for LED luminaires 24 V DC
Safety transformer according to EN 61558/VDE 0570 part 2-6

  • 70 564 Power supply unit for     5-15 W

  • 70 465 Power supply unit for 10-25 W

  • 70 565 Power supply unit for 20-35 W

  • 70 566 Power supply unit for 30-50 W

  • 70 567 Power supply unit for 40-75 W

  • 70 169 Power supply unit for 70-150 W
    230 V y 50-60 Hz

  • 71 134 Power supply unit for 0-70 W

AC range : AC: 198-264 V y 50-60 Hz DC range: DC: 176-275 V
The power supply units are also suitable for the operation of several LED luminaires. In this case, the maximum wattage of the power supply unit must not be exceeded.

Spares

  • Spare glass                                14 000 506
  • LED module 3000 K              LED-0312/930
  • LED module 4000 K               LED-0312/940
  • Gasket                                        83 000 887 .1

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com