super bright leds EL2-CRW LED Emergency Light User Manual
- June 6, 2024
- super bright leds
Table of Contents
User Manual
EL2-CRW. LED Emergency Light
Important: Read all instructions prior to installation.
SAVE THESE INSTRUCTIONS.
Warning
Read and follow all safety instructions. When using electrical equipment,
basic safety precautions should always be followed including the following:
- Disconnect power at fuse or circuit breaker before installing or servicing.
- Do not use outdoors.
- Do not mount in hazardous locations or near gas or electric heaters.
- Do not let power cords touch hot surfaces.
- Equipment should be mounted at heights and locations where it is not subjected to tampering by unauthorized personnel.
- The use of accessory equipment is not recommended.
- Do not use this equipment other than its intended use.
- All services should be performed by qualified personnel.
- Allow the battery to charge for 24 hours before first use.
Specifications
EL2-CRW
Operating Temperature| 32°–104° F (0°–40° C)
Fixture Weight| 0.8 lb (350 g)
Battery Type| Ni-Cd (3.6 V / 900 mAh)
Check the product label for specific electrical specifications related to
installation.
Improper installation will void the warranty.
Cautions
Maintenance
- Not required. Replace the batteries as needed according to ambient conditions. We recommend the equipment be tested regularly in accordance with local codes.
Operation
- Press the test button, the LED heads will turn on and the LED indicator will turn off.
- Release the test switch, the LED indicator will turn on and the LED heads will turn off.
Troubleshooting
- Check AC supply, verify the unit has 24 hours of AC supply before emergency use.
- Verify the unit is shorted or the battery is not connected
Testing
Manual Test
The test buttons can be held to illuminate lights for manual testing purposes.
Wiring Diagram
¹Limited 2-year warranty on the battery.
Installation Instructions
-
Carefully remove the mounting plate by using the release buttons.
-
Remove appropriate knockouts for wiring and mounting from the rear panel.
-
Run the wiring through the mounting plate and connect the wiring to the junction box. Cap unused wire. (refer to wiring diagram)
Note: Red and black wires should never be connected at the same time. -
Securely attach the mounting plate to the surface or junction box with hardware.
-
Connect the battery to the board.
-
Reattach light assembly to the mounting plate.
-
Apply power and allow the battery pack to charge for at least 24 hours before initial use/test.
-
After a 24-hour period, press the test button to make certain lights are functioning as intended.
Rev Date: V1 05/04/2021
4400 Earth City Expy, St. Louis, MO 63045
866-590-3533
superbrightleds.com