Vixen VMC260L Astronomical Telescope Instruction Manual

June 6, 2024
Vixen

Vixen VMC260L Astronomical Telescope Instruction Manual
Vixen VMC260L Astronomical Telescope

PREFACE

Thank you very much for your purchase of a Vixen astronomical telescope.

This manual applies to the VMC260L telescope for the SXD equatorial mount. You may occasionally find descriptions in the text not relevant to your particular model. Read the instructions for your mount along with this manual if you purchased the telescope as a complete package.

WARNING Never look directly at the sun with the telescope or its finder scope or guide scope. Permanent and irreversible eye damage may result.

CAUTION

  • Do not leave the optical tube uncapped in the daytime. Sunlight passing through the telescope or finder scope may cause a fire.
  • Do not use the product while moving or walking, injuries could result from a collision with objects or from stumbling or falling.
  • Keep small caps, plastic bags, or plastic packing materials away from children. These may cause a danger of swallowing or suffocation.
  • Do not use the product in a wet environment and do not handle with wet hands.

SETTING UP

Refer to your mount instructions along with this manual.

  • Attaching the Finder Scope
1. With the Allen wrench, loosen each of the rear three set crews on the bracket ring that holds the finder scope.  

SETTING UP
Loosen the front adjustment screws on the bracket ring to allow passage of the finder scope.

2. Slide the finder scope into the bracket ring from its eyepiece end and tighten the setscrews on the bracket ring lightly with the Allen wrench.  

SETTING UP

3. Tighten the three adjustment screws to hold the finder scope steady  

SETTING UP

4. Loosen the chrome setscrew of the bracket shoe on the telescope. Slide the finder scope onto the bracket shoe and tighten the chrome setscrew.  
  • Attaching the Optical Tube
1. Loosen the dovetail tube plate lock screw and the safety screw before you attach the optical tube.
2. Slide the dovetail slide rail on the bottom of the optical tube onto the mounting platform.  

Tighten the lock screw on the slide rail until snug. Tighten the safety screw.

ALIGNING THE FINDER SCOPE

  • Adjusting the Finder Scope
1. Choose a conspicuos target in the distance and place the target in the center of the field of view of the telescope.  

In the illustration, a distant tower is brought into the center of the field of view of the telescope.

2. As you look through the finder scope, you should find the same target somewhere within the finder‘s field of view. The finder scope has a crosshair.
3. Align the optical axis (field of view) of the finder scope with the optical axis (field of view) of the telescope. Adjust the finder scope by loosening or tightening two of the three adjustment screw at a time, in turn, until the target is in the same position, in the center of the crosshair.  

ACCESSORY CHART

The telescope requires eyepieces to view images. An eyepiece is not included with the VMC260L.
ACCESSORY CHART
ACCESSORY CHART

RE-COLLIMATION

How to Re-collimate the VMC260L Optical Tube

The VMC260L telescopes are collimated properly at Vixen‘s factory before shipment. The telescopes hold the collimation unless they are handled roughly. You can re-collimate your telescope using the following procedure if necessary.

  1. There are three Allen screws for collimation which are placed near the center the fourvane spider on the front of the optical tube.
    RE-COLLIMATION

  2. Attach an eyepiece with medium power (60X to 80X) onto the eyepiece holder and get a relatively bright star such as the Polar star into the telescope´s field of view. Turn the focus knob to defocus the star image fully until it is enlarged and blurred as much as one third of the viewing field. The silhouette of the secondary mirror is seen near the center of the blurred star image at this time.

  3. If the optical axis is aligned correctly, both the blurred star image and silhouette of the secondary mirror can be seen at the center of the telescope‘s field of view. If it is not aligned concentrically, move those images to the center of the field of view. With an Allen wrench, adjust the collimation screw nearest or furthest from the direction of those images.

  4. Turn the collimation screw clockwise or counterclockwise gradually until the blurred star image and silhouette of the secondary mirror are aligned concentrically in the center of the telescope‘s field of view.

  5. Use an eyepiece with high magnification and repeat the above procedures so that you can make more precise re-collimation of the optical axis.

  6. When re-collimation of the telescope is done properly, you perform a star test with a medium to high power eyepiece selecting a star of the second or third magnitude.
    RE-COLLIMATION
    Right after you focus on the star precisely, defocus the star image slightly to look at a diffraction pattern of the star.
    RE-COLLIMATION
    if the concentric diffraction rings can be seen, the optical axis have been re-collimated properly.
    RE-COLLIMATION

RE-COLLIMATION

  1. Re-collimation of the optical axis will go much faster if you have an assistant.
  2. The star image will shift considerably even if the collimation screws are adjusted only a small amount.
  3. If one of the three collimation screws comes to the end in either direction, turn the other two collimation screws on the opposite side to the reverses so that you can continue the re-collimation.
  4. Optical collimation is very delicat and you should avoid turning the collimation screws excessively.

Specifications

Model

| VMC260L Optical Tube Assembly
---|---
Optical Design|

Precision Spherical Mirror & Meniscus Lens System

Effective Aperture

| 260mm
Focal Length|

3000mm

Focal Ratio

| 1 : 11.5
Light Gathering Power|

1380X

Resolving Power

| 0.45 arc seconds
Limiting Magnitude|

13.8

Threads

| 60mm, 42mm for T-Ring
Visual Back|

50.8mm (2.0“), 31.7mm (1.25“)

Optical Tube Length

| 650mm

Outer Diameter

|

304mm

Weight|

10.9 Kgs (24 lbs)

7X50 Finder Scope
(6.8 degrees field of view)

|

Supplied

Flip Mirror Diagonal

| Supplied
Mounting System|

Dovetail Slide Rail and Mounting Platform

Carry Handle

|

Supplied

Handling and Storage

  • Do not leave the product inside a car in bright sunshine or in other hot places. Keep away strong heat at sources away from the product.
  • When cleaning, do not use solvents such as paint thinner or similar products.
  • Avoid touching any lens or mirror surfaces directly with your hands. In case a lens or mirror becomes dirty with fingerprints or general smears, gently wipe it using a commercially available lens ceaner and a lens cleaning paper or cloth, or consult you local Vixen dealer.
  • Blow off dust on lenses using a commercially available blower brush.
  • For storage, keep the product in a dry place and do not expose to direct sunlight.