SAFETY INSTRUCTIONS
- Wear safety glasses. Improper use can result in the risk of personal injury. If you get battery fluid in your eyes, rinse your eyes with clean water for at least 70 minutes and then seek immediate medical attention.
- Improper use of the appliance can result in the risk of explosion and serious personal injury and/or material damage.
- When the appliance is not in use it must be in the OFF position to avoid the risk of personal injury and/or material damage if the clamps are short-circuited.
- Never short-circuit the clamps with a metal object, or by allowing them to touch each other.
- Check that the vehicle battery is 72 V.
- Before starting the appliance check that the battery clamps are connected with the right polarity, otherwise the appliance or the battery could explode and cause serious injury and/or material damage.
- Make sure that the vehicle to be started is in a well-ventilated area.
- Do not expose the appliance to moisture or water.
- Do not take this product apart. Risk of fire, electric shock or exposure to battery chemicals.
- This is a lithium-ion battery. In the improbable event this product leaks battery chemicals avoid contact with skin, eyes or mouth to prevent personal injury or burns. If your skin is exposed to battery chemicals, wash with soap and water and rinse with vinegar. If you get battery chemicals in your eyes, rinse immediately with water and then seek medical attention.
- Charge this product in a well-ventilated area.
- Do not smoke or use naked flame near a battery when it is being charged.
- Never use the auxiliary starter to charge a frozen battery.
- Do not switch the red or black battery clamps after removing the original battery as this can damage the electronics in the car.
- Keep the product out of the reach of children.
- Store the product in a dry and safe place.
- Do not expose the product to temperatures over 70° C or below minus 20°C.
WARNING!
- The appliance cannot be used instead of the vehicle’s own battery.
- First conned the positive clamp to the positive terminal on the battery. Then conned the negative clamp to the negative terminal on the battery, or the vehicle chassis.
SYMBOLS
- Read the instructions.
- Risk of electric shock.
- Contains corrosive substances.
- Approved as per applicable directives.
- Recycle discarded products in accordance with local regulations.
TECHNICAL DATA
- Output voltage 12 V
- Battery capacity 40000 mWh
- Amperage, starting 200A
- Amperage, max 330A
- Input charging port DC 3.5 15 V/1 A
- Working temperatur e -20- 70°C
- Charging time 3-4 hours
Life span
- Number of charges 1000
- Number of over-discharges 80
Outputs
- USB 5 V/2.1 A
- Auxiliary starter, car 12 V
- Electronic 12, 16, 19 V/3.5 A
- Size 158 x 75 x 31 mm
DESCRIPTION INTENDED USE
- The auxiliary starter is intended to start cars, boats etc. with 12 V batteries.
- The built-in battery in the auxiliary starter is charged with the supplied 230 V charger, which is connected to the charger port on the auxiliary starter. The auxiliary starter has a built-in overcharge protection.
- Two USB ports with 5 V DC output voltage to charge mobile phone, computer or equivalent.
PACKAGE CONTENTS
- Auxiliary starter
- Battery cables
- Case
- Charger, 230 V
FIg. 1
FUNCTIONAL DESCRIPTION
- LED lamp
- Battery connector to start car
- LED display
- Output, 12, 16, 19 V/3.5 A
- Function button
- Outputs 5 V/2.1 A
- Input, 15 V/1A
- Power, ON/OFF
FIg. 2
SMART BATTERY CABLE FUNCTION
- Red LED + two quick tones Incorrect battery connection.
- Red LED + one long tone Short-ci rcu it/Overheating protection.
- Red LED + two quick tones Over-discharge protection.
- Green/red LED {flashing) Status search on connection.
- Green/red LED (constant) + one tone Correct connection.
USE
AUXILIARY STARTING OF VEHICLE
Read the vehicle manual before attempting an auxiliary start. Do not run the starter for more than four seconds at once when the auxiliary starter is connected to the battery. If the engine does not turn round or start the problem may not be a flat battery.
-
Check that the auxiliary starter battery is fully charged.
-
Check that the lights and all the other extras in the vehicle are switched off.
-
Put the battery cable in the connector on the auxiliary starter.
FIg. 3 -
Firmly connect the red positive clamp(+) on the auxiliary starter to the positive terminal(+) on the vehicle battery. Connect the black negative clamp(-) to the negative terminal (-) on the battery, or to another earth on the vehicle.
FIg. 4 -
Put the power switch (8) in position ON.
-
Turn the ignition key in the vehicle to start. Do not attempt to start for more than 5 seconds.
FIg.5 -
If the vehicle does not start wait for at least 3 minutes, and then try again.
-
If the engine starts, put the power switch in the OFF position.
-
Remove the battery cable from the auxiliary starter.
FIG. 6 -
Disconnect the auxiliary starter battery cables from the battery.
-
Recharge the built-in battery in the auxiliary starter as soon as possible.
NOTE:
If the connection fails, please press this button until the green light turns on, where after you can start the car.
BILD 7
WARNING!
Make sure that the two cables(+) and(-) do not touch each other.
CHARGING THE AUXILIARY STARTER BATTERY
- Connect the charger to the input (7 ) on the auxiliary starter.
- Connect the charger to a PowerPoint.
NOTE:
- Only use the supplied charger. Other chargers can reduce the life span of the battery, or cause it to explode and cause personal injury or material damage.
- Charge the built-in battery in the auxiliary starter before using it for the first time.
- Charge the built-in battery in the auxiliary starter every three months if not in use.
LED LIGHT
- Press the function button (5) for three seconds to start LED light.
- Press the function button again (5) to switch to SOS (flashing).
- Press the function button once again (5) to switch off the light.
MAINTENANCE
CHARGING INSTRUCTIONS
- Fully charge the battery before using it for the first time.
- Always recharge the battery after use.
- Fully charge the battery every 3 months.
TROUBLESHOOTING
Problem
Nothing happens after pressing the function button (5).
| Cause
The low voltage protection on the auxi liary starter is enab led.
| Solution
Charge the auxiliary starter to disable the low voltage protection.
---|---|---
The auxi li ary starter switches off automatically when seve ral electronic
devices are charged at the same time .| ****
Th e overcurrent protection is enabled on the device.
| ****
Charge the electronic devices on separate USB ports and do not exceed 3.5 A.