MEEC TOOLS 015269 Submersible Pump Instruction Manual
- June 6, 2024
- MEEC TOOLS
Table of Contents
MEEC TOOLS 015269 Submersible Pump Instruction Manual
Important! Read the user instructions carefully before use. Save them for future reference. (Translation of the original instructions)
Care for the environment!
Recycle discarded product in accordance with local regulations.
Jula reserves in the right to make changes. For latest version of operating instructions, see www.jula.com
SAFETY INSTRUCTIONS
- This product can be used by children from 8 years and upwards and by persons with physical, sensorial or mental disabilities, or persons who lack experience or knowledge, if they are supervised or receive instructions concerning the safe use of the product and understand the risks involved with its use. Do not allow children to play with the product. Do not allow children to clean or maintain the product without supervision.
- Keep children under supervision to make sure they do not play with the product. Do not allow children to clean or maintain the product without supervision.
- Familiarise yourself with the controls on the product and how to use them. Read all the instructions and safety instructions before use. Failure to follow all the instructions and safety instructions can result in a risk of electric shock, serious personal injury and/or material damage.
- Contact the retailer or qualified personnel if you have any problems or questions.
- Store these instructions so that they are readily available for everyone who uses the product. These instructions should be enclosed with the product if it is sold or passed on.
- Do not make any modifications to the product. Only use accessories recommended by the manufacturer.
- The product must only be used for its intended purpose and in accordance with these instructions. The product must only be used for its intended purpose and in accordance with these instructions, otherwise there is a risk of personal injury and/or material damage. The manufacturer cannot accept liability for personal injury and/or material damage resulting from improper use.
- A damaged cord or plug must be replaced by an authorised service centre or qualified person to ensure safe use.
- Do not use the product if it is damaged. Always check the power cord, plug and casing before use. If the product is damaged, or not working properly, it must be repaired or discarded.
- Pull out the plug immediately if the power cord or product gets damaged or stops working properly, otherwise there is a risk of electric shock.
- Qualified personnel must carry out repairs. Imperfect repairs can result in a risk of electric shock, serious personal injury and/or material damage.
- Do not pull the power cord to pull out the plug.
- Do not allow the power cord to hang over the edge of a table or worktop, or to come in contact with hot surfaces. Avoid kinking or bending the power cord.
- If an extension cord is used the cross-sectional area of the wires must be dimensioned for the power supply to the product.
- If the product is used outdoors, only use an extension cord approved for outdoor use.
- The product is not intended to transport water for human consumption.
- Do not use the product to transport corrosive, flammable or explosive substances such as petrol or other petroleum products, nitrogenous liquids, grease, oil, salt water or waste water from toilets, or liquid that has a higher viscosity than water.
- The temperature of the pumped liquid must not exceed 35°C.
- Keep this product out of the reach of children.
- Do not use the product if there are any persons in the water.
- Make sure the product does not suck up aquatic animals, such as fish.
- Pay attention to the risk of contaminating the liquid as a result of leaking lubricant.
- Protect electrical connections from moisture.
- Do not expose the product to temperatures below 0°C. Make sure that the product is not run without liquid.
- Do not pump aggressive liquids or abrasive material.
- Do not pull the power cord or float switch cord to move the product, and do not use them to secure the product from moving.
- The product is only intended for household use and is not suitable for commercial purposes.
- The manufacturer cannot accept liability for personal injury or material damage resulting from improper use.
The product must be connected to the mains with a residual current device of max 30 mA.
Symbols
| Read the instructions.
---|---
| Approved in accordance with the relevant directives.
| Recycle discarded product in accordance with local regulations.
TECHNICAL DATA
Rated voltage 230 V 50 Hz
Nominal input power 250 W
Pump pressure 0.6 bar
Flow 100 1/min
Lifting height max 6 m
Submersion depth max 7 m
Particle size max 5 mm
Water temperature max 35°C
Ambient temperature max 40°C
Protection rating IPX8
Cord length 5m
Connection 1″ G 1″ 1-1/4″ G1-1/4″
Size L15,8 x W16,3 x H28,3 cm
Weight 3.25 Kg
Always wear ear protection.
The declared values for vibration and noise, which have been measured according to a standardized test method, can be used to compare different tools with each other and for a preliminary assessment of exposure. The measurement values have been determined in accordance with EN ISO 3744:1995.
WARNING!
The actual vibration and noise level when using tools may differ from the specified maximum value, depending on how the tool is used and the material. It is therefore necessary to determine which safety precautions are required to protect the user, based on an estimate of exposure in actual operating conditions (taking into account all stages of the work cycle, e.g. the time when the tool is switched off and when it is idling, in addition to the start- up time).
DESCRIPTION
Pump for draining and pumping clean water (max 5 mm particles). Connects to earthed power point. Not suitable for continuous operation. Minimum water level to start: 100 mm. Residual level 5 mm.
PRODUCT PARTS
- Handle
- Hose adapter for outlet connection
- Tube bend
- Suction inlet
- Float switch
- Power cord and plug
- Clip for float switch
FIG. 1
INSTALLATION
INSTALLATION AND COMMISSIONING
Fasten a suitable line to the handle before using for the first time. The line is used to lower the product down into the water and to carry it.
NOTE:
If the product is used hanging from the line, the line must be checked at regular intervals for wear and damage.
Connection of outlet tube
Temporary use
For temporary use you can use a water hose with a diameter of 1 inch (25 mm) to 11/2 (38 mm) inches.
Permanent installation
For permanent installation a tube and non-return valve are recommended to prevent return flow when the product is switched oft
- Screw the outlet tube on the outlet connection.
- When using a hose, screw the hose adapter on the outlet connection.
- Press the hose firmly on the hose adapter and secure with a hose clip.
- The hose adapter can be cut as shown in the figure. In which case the hose is connected with a 11/4 inch (32 mm) cap nut.
IMPORTANT:
Risk of material damage. Tighten the hose adapter by hand during assembly.
The threads can be damaged if overtightened.
INSTALLATION
In order to work properly the product needs a free space of at least 50 x 50 cm for the float switch to move freely. The product can be used submerged, down to the depth specified in the technical data.
- Install the product so that the intake openings cannot be blocked. Put it on a level, stable surface, if necessary.
- Check that the product is stable.
IMPORTANT
Risk of material damage. Do not lift the product by the cord or the outlet tube, they are not designed to support the weight of the product.
- Lower the product at an angle into the water so that no air remains underneath — otherwise this prevents suction. Once the product is submerged, it can be straightened up.
- Place the product on the bottom of the tank. Lower it down with a line fastened to the handle.
- Fasten the end of the line securely to lower the product.
- The product can also be used suspended from the line.
NOTE:
When used hanging on the line: Do not run the product without the outlet tube connected. Make sure the product does not turn around its longitudinal axis.
USE
When the product is connected to the power supply it starts and stops
automatically with the float switch.
FIG. 2
-
The product starts when the level of the water rises and the float switch lifts (1).
The product switches off when the float switch has sunk to the bottom (2). -
The level switch cord can move in the clip (3). The different levels between starting and stopping can be adjusted as follows.
-
Short cord: Start and stop levels close to each other.
-
Long cord: Start and stop levels well away from each other.
IMPORTANT:
Risk of material damage. The float switch must be able to move so that the product cannot run dry.
MAINTANANCE
BEFORE USE
- Check the casing and cords for damage.
- Check the float switch for damage. Lift and shake the float switch to check that the metal balls move.
AFTER EACH USE
Clean the product.
External cleaning
Rinse with clean water. Remove stubborn stains with a brush and detergent. Lower the product into a container with clean water and run for a short time to flush the inside of the product.
Cleaning the intake
Clear the inlet. Open the pressure tube connection and remove any fibres that have wound around the rotor shaft. Remove stubborn stains with a brush and detergent.
NOTE:
Before using the product again, allow it to stand in the water for a while to prevent any deposits and residue from clogging it.
STORAGE
If there is a risk of frost, dismantle and clean the product and its accessories and store in a frost-free place.
IMPORTANT:
Risk of material damage. The product and its accessories contain water, which means that they can burst if the water freezes.
TROUBLE SHOOTING
Problem | Possible cause | Proposed action |
---|---|---|
the product does not work. | No power supply. | Check the power cord, plug, |
power point and fuse.
The float switch does not activate the product.| Check that the water level is
sufficient.
Check that the float switch can move freely.
The float switch is defective.| Contact the retailer
The motor overheats because
-
the temperature of the
water is too hot. -
the product is blocked.
| Eliminate the cause of overheating. The maximum temperature of the water is
indicated in the technical data.
The residual current device has tripped.| Reset the residual current device.
Contact an authorised electrician if the residual current device continues to
trip.
Defective motor.| Contact the retailer.
The product runs, but delivers no water.| The intake opening is blocked.|
Clear.
The product sucks air.| Tilt the product when it is submersed in the water.
Switch the product on and off several times to remove the air.
The product is blocked.| Clear the product.
Reduced flow.| Excessive lifting height.| Do not exceed the maximum lifting
height.
Pressure tube diameter too small.| Use a larger pressure tube.
The pressure tube blocked.| Clear.
The intake opening is blocked.| Clear the intake opening.
The pressure tube is bent.| Straighten out the pressure tube.
Leak in the pressure tube.| Seal the pressure tube and all connections.
The product makes a noise.| The product sucks air.| Check that the water level
is sufficient.
Set the float switch correctly.
Tilt the product when it is submersed in the water
The product does not stop.| The float switch does not reach
its lowest position.
| Pull out the plug. Check that the float
switch can move freely.
The float switch is defective.| Contact the retailer.