MEEC TOOLS 015255 Hydrophore Pump Instruction Manual

October 30, 2023
MEEC TOOLS

MEEC TOOLS 015255 Hydrophore Pump

Product Information

  • Item Number: 015255
  • Product Name: Hydrophore Pump
  • Flow Rate: 51.6 L/min
  • Dimensions: L44 x B27 x H48 cm
  • Weight: 10.6 Kg
  • Complies with Directives/Regulations: MD 2006/42/EC EMC 2014/30/EU OND 2000/14/EC + 2005/88/EC RoHS 2011/65/EU + 2015/863
  • Harmonised Standard: EN 60335-1:2012+A11+A13, EN 60335-2-41:2003+A1+A2, EN 62233:2018 EN 55014-1:2017+A11, EN 55014-2:2015,EN IEC 61000-3-2:2019, EN 61000-3-3:2013+A1 EN 50581:2012
  • Noise Level: 73.7 dB(A)

Product Usage Instructions

  1. Before use, carefully read the user instructions provided with the product and save them for future reference.
  2. Connect the suction hose to the water inlet of the pump.
  3. Connect the discharge hose to the outlet of the pump.
  4. Plug the pump into a power outlet with the voltage and frequency specified in the technical data.
  5. The pump will start automatically when the pressure in the system falls below a certain level.
  6. Monitor the pump to ensure that it is operating correctly and does not overheat.
  7. If there is air in the pump or the pressure in the system falls quickly, adjust the air pressure in the storage tank to 2.0 bar or replace the membrane or clean the inlet filter or check valve.
  8. Follow all safety instructions provided with the product, including reading the user instructions and complying with local regulations for discarding and recycling the product.

Care for the environment
Recycle discarded product in accordance with local regulations.

SAFETY INSTRUCTIONS

  • This product can be used by children from 8 years and upwards and by persons with physical, sensorial or mental disabilities, or persons who lack experience or knowledge, if they are supervised or receive instructions concerning the safe use of the product and understand the risks involved with its use. Do not allow children to play with the product. Do not allow children to clean or maintain the product without supervision.

  • Keep children under supervision to make sure they do not play with the product. Do not allow children to clean or maintain the product without supervision.

  • Familiarise yourself with the controls on the product and how to use them. Read all the instructions and safety instructions before use. Failure to follow all the instructions and safety instructions can lead to the risk of electric shock, serious personal injury and/or material damage.

  • Contact the retailer or qualified personnel if you have any problems or questions.

  • Store these instructions so that they are readily available for everyone who uses the product. These instructions should be enclosed with the product if it is sold or passed on.

  • Do not make any modifications to the product. Only use accessories recommended by the manufacturer.

  • The product must only be used for its intended purpose and in accordance with these instructions. The product must only be used for its intended purpose and in accordance with these instructions, otherwise there is a risk of personal injury and/or material damage. The manufacturer cannot accept liability for personal injury and/or material damage resulting from improper use.

  • A damaged cord or plug must be replaced by an authorised service centre or qualified person to ensure safe use.

  • Do not use the product if it is damaged. Always check the power cord, plug and casing before use. If the product is damaged, or not working properly, it must be repaired or discarded.

  • Pull out the plug immediately if the power cord or product gets damaged or stops working properly, otherwise there is a risk of electric shock.

  • Qualified personnel must carry out repairs. Imperfect repairs can result in a risk of electric shock, serious personal injury and/or material damage.

  • Do not pull the power cord to pull out the plug.

  • Do not allow the power cord to hang over the edge of a table or worktop, or to come in contact with hot surfaces.
    Avoid kinking or bending the power cord.

  • If an extension cord is used the cross-sectional area of the wires must be dimensioned for the power supply to the product.

  • If the product is used outdoors, only use an extension cord approved for outdoor use.

  • The product is not intended to transport water for human consumption.

  • Do not use the product to transport corrosive, flammable or explosive substances such as petrol or other petroleum products, nitrogenous liquids, grease, oil, salt water or waste water from toilets, or liquid that has a higher viscosity than water.

  • The temperature of the pumped liquid must not exceed 35°C.

  • Keep this product out of the reach of children.

  • Do not use the product if there are any persons in the water.

  • Make sure the product does not suck up aquatic animals, such as fish.

  • Pay attention to the risk of contaminating the liquid as a result of leaking lubricant.

  • Protect electrical connections from moisture.

  • Do not expose the product to temperatures below 0°C. Make sure that the product is not run without liquid.

  • Do not pump aggressive liquids or abrasive material.

  • Do not pull the power cord or float switch cord to move the product, and do not use them to secure the product from moving.

  • The product is only intended for household use and is not suitable for commercial purposes.

  • The manufacturer cannot accept liability for personal injury or material damage resulting from improper use.

  • The product is intended to be used with a domestic water tank. When the pump is used to boost pressure, the maximum inlet pressure to the pump (1.0 bar) must not be exceeded.

IMPORTANT: The product must be connected to the mains with a residual current device of max 30 mA.

SYMBOLS

TECHNICAL DATA

  • Rated voltage 230: V ~ 50 Hz
  • Nominal input power: 600 W
  • Pump pressure: 2.6 bar
  • Tank volume: 19 l
  • Flow: 51.6 l/min
  • Lifting height: max 35 m
  • Suction height: max 8 m
  • Water temperature: max 35°C
  • Ambient temperature: max 40°C
  • Safety class: I
  • Protection rating: IPX4
  • Cord length: 1 m
  • Inlet connection: 1″(R25)
  • Outlet connection: 1″ (R25)
  • Size: L44 x W27 x H48 cm
  • Weight: 10.6 Kg
  • LpA¹: 60.8 dB(A), K=2.8 dB
  • LwA²: 73.7 dB(A), K= 2.8 dB
  • LwA³: 77 dB(A)
  1. Sound pressure level
  2. Measured sound power level
  3. Guaranteed sound power level

Always wear ear protection.
The declared values for vibration and noise, which have been measured according to a standardised test method, can be used to compare different tools with each other and for a preliminary assessment of exposure. The measurement values have been determined in accordance with EN ISO 3744:1995.

WARNING: The actual vibration and noise level when using tools may differ from the specified maximum value, depending on how the tool is used and the material. It is therefore necessary to determine which safety precautions are required to protect the user, based on an estimate of exposure in actual operating conditions (taking into account all stages of the work cycle, e.g. the time when the tool is switched off and when it is idling, in addition to the start-up time).

DESCRIPTION

Energy-saving fully automatic hydrophore pump that with its 600 W delivers an impressive flow of 3100 l/h and is perfect for a fully automatic water supply or circulation under constant pressure. Complete with manometer. Max water temperature 35°C.

PUMPABLE LIQUIDS

  • Processed water
  • Well water
  • Water from spring
  • Rainwater
  • Pool water (on the assumption that additives are correctly dosed)

PRODUCT PARTS

  1. Power cord and plug
  2. Water inlet
  3. Water outlet
  4. Mechanical pressure switch
  5. Pressure gauge
  6. Cap over refill opening FIG. 1MEEC-TOOLS-015255-Hydrophore-Pump-FIG-1

USE

BEFORE USE

  • Check that the mains voltage corresponds to the rated voltage on the type plate.
  • It is recommended to use a pre-filter and intake system with suction hose, inlet grille and non-return valve to prevent slow filling of water and damage to the pump from stones and other solid particles.
  1. Remove the product from the packaging and place it on a level, stable surface. Fix in place with screws (sold separately) if necessary. FIG. 2

  2. Connect the suction hose to the water inlet and the outlet hose to the water outlet. FIG. 3MEEC-TOOLS-015255-Hydrophore-Pump-FIG-3

  3. Open the refill opening cap and fill with water until it runs over. Replace the cover.
    NOTE: Even minor leakage can lead to malfunction. FIG. 4MEEC-
TOOLS-015255-Hydrophore-Pump-FIG-4

  4. Plug in the plug and start the pump.
    NOTE: The preset start pressure is 1.5 bar and the preset stop pressure is 3 bar. This is suitable for most installations. Any adjustment should be carried out by qualified personnel. FIG. 5MEEC-TOOLS-015255-Hydrophore-Pump-
FIG-5

  5. Switch off the product and pull out the plug after use. Drain the water from the product by opening the drain on the pump. The water in the tank can also be drained as shown in the figure.FIG. 6MEEC-TOOLS-015255-Hydrophore-Pump-FIG-6

MAINTENANCE

WARNING: Switch off the product and pull out the plug before maintenance and/or cleaning.

NOTE:

The system is pressurised.
After opening the refill cap or the drain, and before releasing the connecting hoses, open the shut-off valve on the outlet side and drain the water from the system with a drain cock (sold separately).

  • REPAIRS: Any repairs and replacement of spare parts should be carried out by an authorised service centre, otherwise there is a risk of personal injury and/or material damage. Switch off the product and pull out the plug before working on the product.
  • STORAGE: Store the product in a frost-free place.

TROUBLESHOOTING

Problem Cause Action

The product runs, but delivers no water.

| Air in the pump.| See section on preparations.
Air does not come out on the outlet side.| Open the tap on the outlet side.



The product does not work, or suddenly stops when running.

| Power supply disconnected.| Check fuses and connections.
The overheating protection trips and switches off the product.| Pull out the plug, allow the product to cool, and clear the intake system. Prevent dry running.





The motor starts again immediately after switching off.

| ****

The pressure in the system drops quickly.

| Check all the connections and seals, and check the water outlet. Even very minor leakage has an adverse effect.
Air pressure too low in the storage tank.| Adjust the air pressure in the storage tank to 2.0 bar.
The non-return valve does not close properly.| Check the non-return valve on the suction side.
The diaphragm in the pressure tank is damaged.| Replace the diaphragm.





The transported amount of water is too little.

| The inlet filter is dirty, or the non-return valve does not close properly.| Clean the inlet filter or non-return valve.
The transported amount of water depends on the total lifting height and the arrangement of the lines.| Do not exceed the maximum permitted lifting height as per section on technical data. Use lines with another diameter and/ or length.
The pre-filter is dirty.| Remove the filter and clean under running water.
Vibrating noise when water is taken out.| The diaphragm in the pressure tank vibrates.| Noise can be reduced by reducing the air pressure in the storage tank.

EU DECLARATION OF CONFORMITY

  • Item number

This declaration of conformity is issued under the sole responsibility of the manufacturer

HYDROPHORE PUMP
Conforms to the following directives, regulations and standards

MEEC-TOOLS-015255-Hydrophore-Pump-FIG-8

This product was CE marked in year:

Mattias Lif BUSINESS AREA MANAGER (Signatory for Jula and authorised to compile the technical documentation

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals