MEEC TOOLS 015272 Fountain Pump Instruction Manual

June 5, 2024
MEEC TOOLS

MEEC TOOLS 015272 Fountain Pump Instruction Manual

MEEC TOOLS 015272 Fountain Pump Instruction Manual

FOUNTAIN PUMP
OPERATING INSTRUCTIONS Important! Read the user instructions carefully before use. Save them for future reference. (Translation of the original instructions).

Care for the environment!
Recycle discarded product in accordance with local regulations.
Jula reserves the right to make changes. For latest version of operating instructions, see www.jula.com

JULA AB, BDX 363, SE-~32 24 SKARA
2022 03 28
© Jula AB

EU DECLARATION OF CONFORMITY
Item number   015272

This declaration of conformity is issued under the sole responsibility of the manufacturer.

FOUNTAIN PUMP 230V, 75W, 26001/h
Conforms to the following directives, regulations and standards:

MEEC TOOLS 015272 Fountain Pump Instruction Manual -
Directive

Mattias Lif
BUSINESS AREA MANAGER (Signatory for Jula and authorised to compile the technical documentation.

MEEC TOOLS 015272 Fountain Pump Instruction Manual - Fig.
1 MEEC TOOLS 015272 Fountain Pump
Instruction Manual - Fig. 2 MEEC TOOLS
015272 Fountain Pump Instruction Manual - Fig. 3,4 MEEC TOOLS 015272 Fountain Pump Instruction Manual - Fig.
5,6 MEEC TOOLS 015272 Fountain
Pump Instruction Manual - Fig. 7,8

SAFETY INSTRUCTIONS

  • Only use the fountain pump for its intended purpose, and always follow these safety instructions. Failure to follow all the instructions and safety instructions can result in a risk of fire, electric shock, and/or serious personal injury.
  • Check that the mains voltage corresponds to the rated voltage on the type plate.
  • The user is responsible for any direct or indirect damage as a result of incorrect use.
  • Do not pump acidic or alkaline liquids, or water with a high content of chlorine. Such liquids reduce the life span of the product and can result in a risk of personal injury. Follow local regulations concerning the use of the product.
  • Do not use the fountain pump in salt water. Switch off the product before removing it from the water.
  • Do not run the fountain pump dry. This can cause irreparable damage.
  • Do not use the fountain pump if the power cord or pump housing are damaged.
  • Do not use the product without the connected tubes, or if the tubes are leaking.
  • The fountain pump must only be connected to an earthed power point (do not use unearthed power points or extension cords).
  • Do not repair or replace a damaged power cord. The fountain pump must be discarded if the power cord is damaged.
  • Do not carry the fountain pump by the power cord. Use a residual current device with a maximum tripping current of 30 mA.
  • This appliance can be used by children aged from 8 years and above and people with reduced physical, sensory or mental capabilities or lack of experience and knowledge ii they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance tasks may not be carried out by children unless they are supervised.
  • Follow the applicable legislation and directives when using the fountain pump 1n a garden pond or pool. Contact an authorised electrician in the event of any uncertainty.
  • The fountain pump must not be in use when there are persons in the water.
  • Outdoor use is only permitted in combination with a 10 metres long mesylated rubber cable.
  • Switch off the power to all electrical products in contact with the water before cleaning or maintaining the fountain pump.
  • Switch off the product immediately if the wires are damaged.
    NOTE: The wires are not replaceable.
SYMBOLS

MEEC TOOLS 015272 Fountain Pump Instruction Manual -
SYMBOLS

TECHNICAL DATA

MEEC TOOLS 015272 Fountain Pump Instruction Manual - Technical
Data

DESCRIPTION

The fountain pump from Meec Tools makes the pond even nicer to look at and oxygenates the water at the same time, which helps both plants and wildlife to thrive even better. Supplied with side adapter for connection to separate waterworks – e.g. waterfall. Three different nozzles included (bell, foam and step).

  1. Inlet grille with BIOCELL insert
  2. Fountain pump
  3. Carry handle
  4. Coupling sleeve
  5. Flow divider
  6. Fountain pipe
  7. Step jet nozzle
  8. Bell jet nozzle
  9. Foam effect nozzle
    FIG. 1
INTENDED USE

The product is a fountain pump intended for continuous use in garden fountains.

FUNCTIONS AND FEATURES
  • Oil-free motor
  • Stator hermetically sealed in moulded resin
  • Water-jacketed permanent magnetic rotor
  • Three different nozzles
  • Side adapter for waterworks
  • Oxygenates the water
SUPPLIED PARTS
  • Fountain pump
  • Coupling sleeve
  • Flow divider
  • Fountain pipe
  • Step jet nozzle
  • Bell jet nozzle
  • Foam effect nozzle
  • Operating instructions

USE

Carefully read all the instructions and safety instructions before use, and familiarise yourself with the product and how to use it.

PREPARATION
  • Open the packaging and carefully remove the product.
  • Remove all packaging materials and any transport protection parts.
  • Check that no parts are missing or damaged. Do not use the product if any parts are missing or damaged – contact the retailer.
  • If possible save the original packaging during the warranty period.

WARNINC!

Keep the packaging materials and product out of the reach of children. Risk of suffocation and swallowing of small parts if children play with plastic bags, plastic foil and small parts.

BEFORE USE

Check that the mains voltage corresponds to the rated voltage on the type plate.

BIOCELL INLET FILTER

The inlet filter has a BIOCELL insert. BIOCELL is a special material for natural, biological water purification. Conventional mechanical filters only remove dirt particles, for example plant residues and dead insects, while biological filters also remove finely dispersed pollutants and turbidity. This is achieved by means of saltpetre forming bacteria. The porous BIOCELL material is specially developed to give this bacteria ideal conditions for
survival and propagation. Toxic organic substances are converted to natural plant nutrition in the BIOCELL filter- a natural process that contributes to the biological equilibrium of the garden pond.

NOTE:

  • The product must be protected from frost even when continually running. If the pump is used in areas where there is a risk of frost it should therefore be switched off and put away during the frost season.
  • The product must only be used for its intended purpose and in accordance with these instructions. All other use is considered to be unsuitable. The manufacturer cannot accept liability for any damages resulting from improper usage.
  • The product is only intended for household use and is not suitable for commercial purposes. The warranty will be invalidated if the product is used commercially, for example in industry or professional craftsmanship.
  1. Fasten the flow divider (5) with the coupling sleeve (4) on the fountain pump (1).
  2. Screw the fountain pipe (6) in the flow divider (5). The end with the flange and seal must be facing up.
  3. Fit the required fountain nozzle on the fountain pipe (6): step jet nozzle (7), bell jet nozzle (8) or foam effect nozzle (9).
MAINS CONNECTION

The product is supplied with an earthed plug. The product must be connected to an earthed power point with a voltage of 230 V ~ 50 Hz. The power point must be in good condition and fused with at least 6 A. The product is ready to use as soon as it is plugged in.

NOTE:
Never run the fountain pump without water.

FOUNTAIN USE

There are 3 fountain alternatives:

  • fountain only (step jet, bell jet or foam effect jet)
  • fountain plus waterworks via the flow divider
  • waterworks only via the flow divider
Spray pattern
  1. Bell jet
  2. Step jet
  3. Foam effect  FIG. 2
Fountain only

Place the product in the pond so that the fountain nozzle sticks up over the surface of the water. The tap (A) on the flow divider must be turned a quarter of a turn clockwise to closed position when only the fountain is used. The tap (B) must be open. FIG. 3

Fountain and waterworks

Position the product as described above. The flow divider makes it possible via a hose with an inner diameter of 13 mm to distribute water to waterworks. The tap (A) must then be turned a quarter of a turn anticlockwise to open position.

Waterworks only

For waterworks only the tap (B) must be turned a quarter of a turn clockwise to closed position. The tap (A) must be open. The flow of water then flows out in the hose to the waterworks and no water goes to the fountain. FIG. 4

MAINTENANCE

WARNING!

  • Switch off the product and pull out the plug before maintenance.
  • There is a risk of electric shock if water gets into an electrical product.
GENERAL

Pull out the plug if the product is not going to be used for some time. Allow the product to cool to the ambient temperature. Dismantle the product and clean, and if necessary maintain the parts. Store the product in a clean, dry, frost-free place.

CLEANING
  • The product must be checked and maintained at regular intervals to ensure correct and reliable functionality and a long life span.
  • Clean the product regularly with a cloth moistened with a soap solution. Do not use detergent that contains solvents or corrosive or abrasive additives – risk of damaging the surface of the product. Take care not to damage the power cord or other electrical components.
  • The filter should be cleaned with lukewarm water if the head height or flow of the product is reduced.
  • The rotating parts on the product should be cleaned at regular intervals if the pumped water is hard (high lime content).
Cleaning the impeller
  1.  Release the inlet grille (2) by turning it in the direction of the arrow. FIG. 5

  2. Unscrew the screw (1) anticlockwise. FIG. 6
    WARNING
    Flat washers are placed over and under the impeller. Do not mislay these when removing the casing and impeller, and remember to replace them when refitting the impeller.

  3. Turn the impeller casing (2) anticlockwise. FIG. 7

  4. Now remove the impeller. FIG. 8

  5. Rinse the impeller and pump with clean water and refit in the reverse order.

STORAGE

Follow the instructions below when putting the pump into storage.

  • Before long term or winter storage the pump should be thoroughly rinsed with water, fully emptied and allowed to dry.
  • The complete emptying of the pump is essential if there is a risk of frost.
  • During long term storage the product should be run for a short time now and then to ensure that the rotating parts do not stick.

TROUBLESHOOTING

MEEC TOOLS 015272 Fountain Pump Instruction Manual -
Troubleshooting