Westinghouse iGen4500DF Digital Inverter Generator User Manual

June 5, 2024
Westinghouse

Westinghouse logo

Westinghouse iGen4500DF Digital Inverter Generator

Digital Inverter Generator
Gasoline: 3700 Running Watts | 4500 Peak Watts Propane: 3330 Running Watts | 4050 Peak Watts

DO NOT RETURN THIS PRODUCT TO THE STORE
If you have questions or need assistance, please call customer service at 855-944-3571.

INTRODUCTION

WARNING: Operating, servicing, and maintaining this equipment can expose you to chemicals including engine exhaust, carbon monoxide, phthalates, and lead, which are known to the State of California to cause cancer and birth defects or other reproductive harm. To minimize exposure, avoid breathing exhaust, and wear gloves or wash your hands frequently when servicing this equipment. For more information go to www. P65warnings.ca.gov.

DISCLAIMERS
All information, illustrations, and specifications in this manual were in effect at the time of publishing. The illustrations used in this manual are intended as representative reference views only. We reserve the right to make any specification or design change without notice.

ALL RIGHTS RESERVED
All rights reserved. No reproduction allowed in any form without written permission from Westinghouse Outdoor Power Equipment, LLC.

DANGER
Read this manual before using or performing maintenance on this product. Failure to follow the instructions and safety precautions in this manual can result in serious injury or death.

SPECIFICATIONS

SPECIFICATIONS

Model:| iGen4500DF
Running Watts:| 3700 Gas / 3330 LPG
Peak Watts:| 4500 Gas / 4050 LPG
Rated Voltage:| 120V
Rated frequency:| 60 Hz
Phase:| Single phase
Total Harmonic Distortion:| ≤ 3%
Engine Displacement:| 224 cc
Starting Type:| Recoil, Electric Start, Remote
Fuel Capacity:| 3.4 Gal (12.8 L)
Fuel Type:| 87–93 octane ***
Oil Capacity:| 0.63 US qt (0.60 L)
Oil Type:| 10W30
Spark Plug:| F7RTC
Spark Plug Gap:**| 0.024 – 0.032 in.

(0.60 – 0.80 mm)

Valve Intake Clearance:| 0.0031 – 0.0047 in

(0.08 – 0.12 mm)

Valve Exhaust Clearance:| 0.0051 – 0.0067 in

(0.13 – 0.17 mm)

AC Grounding System:| Floating neutral
Voltage Regulator:| Digital
Alternator Type:| Permanent magnet
Maximum Ambient Temperature:| 104°F (40°C)


Certifications:

| •    EPA

•    CARB

•    CSA Group

*Ethanol content of 10% or less. DO NOT use E15 or E85.

NOTICE
This product is designed and rated for continuous operation at ambient temperatures up to 104°F (40°C). If needed, this product can be operated at temperatures ranging from 5°F (15°C)–122°F (50°C) for short periods. If the product is exposed to temperatures outside of this range during storage, it should be brought back within this range before operation. This product must always be operated outdoors in a well-ventilated area and away from doors, windows, and other vents.
Maximum wattage and current are subject to and limited by such factors as fuel BTU content, ambient temperature, altitude, engine conditions, etc. Maximum power decreases about 3.5% for each 1,000 feet above sea level, and will also decrease about 1% for each 10°F (6°C) above 60°F (16°C) ambient temperature.

PRODUCT REGISTRATION
For trouble-free warranty coverage, it is important to register your Westinghouse generator.
You can register by:

  • Completing and mailing the product registration card included in the carton.

  • Registering your product online at:
    https://westinghouseoutdoorpower.com/pages/warranty-registration

  • Scanning the following QR code with your smartphone camera. You will be directed to the mobile registration link.

  • Sending the following product information to:

Westinghouse Outdoor Power Warranty registration
777 Manor Park Drive Columbus, OH 43228

For Your Records

Date of Purchase:
Model Number:
Serial Number:
Place of Purchase:

IMPORTANT: Keep your purchase receipt for trouble-free warranty coverage.

SAFETY

SAFETY
SAFETY DEFINITIONS
The words DANGER, WARNING, CAUTION and NOTICE are used throughout this manual to highlight important information. Make sure that the meanings of this safety information is known to all who operate, perform maintenance on, or are near the generator.

This safety alert symbol appears with most safety statements. It means attention, become alert, your safety is involved! Please read and abide by the message that follows the safety alerts symbol.

DANDER
Indicates a hazardous situation which, if not avoided, will result in death or serious injury.

WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.

CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.

NOTICE
Indicates a situation which can cause damage to the generator, personal property, and/or the environment, or cause the equipment to operate improperly.

Note: Indicates a procedure, practice or condition that should be followed for the generator to function in the manner intended.

SAFETY SYMBOLS
Follow all safety information contained in this manual and on the generator.

Westinghouse iGen4500DF Digital Inverter Generator-1

SAFETY INSTRUCTIONS

CORRECT USE
Example location to reduce risk of carbon monoxide poisoning

  • ONLY use outside and downwind, far away from windows, doors and vents.
  • Direct exhaust away from occupied spaces

Westinghouse iGen4500DF Digital Inverter Generator-2

INCORRECT USE
Do not operate in any of the following locations:

  • Near any door, window, or vent
  • Garage
  • Basement
  • Crawl Space
  • Living Area
  • Attic
  • Entry Way
  • Porch
  • Mudroom

NOTICE
Install battery-powered carbon monoxide detectors or plug-in carbon monoxide detectors with battery back-up in living areas.

DANGER
Fire and electrocution hazard. Do not connect to a building’s electrical system unless the generator and transfer switch have been properly installed and the electrical output has been verified by a qualified electrician. The connection must isolate the generator power from utility power and must comply with all applicable laws and electrical codes.

  • Electrocution hazard. Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit.

GENERAL SAFETY PRECAUTIONS

  • Never use the generator to power medical support equipment.

  • Do not operate the generator when you are tired or under the influence of drugs, alcohol, or medication.

  • Do not use generator with electrical cords which are worn, frayed, bare, or otherwise damaged.

  • All electrical tools and appliances operated from this generator must be properly grounded by use of a third wire or be double-insulated.

  • When this generator is used to supply a building wiring system the generator must be installed by a qualified electrician and connected to a transfer switch as a separately derived system in accordance with NFPA 70, National Electrical Code.

  • If you begin to feel sick, dizzy, or weak while using the generator, move to fresh air IMMEDIATELY. See a doctor, as you can have carbon monoxide poisoning.

  • Only use OUTSIDE and far away from windows, doors, and vents as recommended by the US Department of Health and Human Services Centers for Disease Control and Prevention. Your specific home and/or wind conditions may require additional distance.

  • While operating and storing, keep at least 3 feet of clearance on all sides of the generator, including overhead. Allow the generator to cool a minimum of 30 minutes before storage. Heat created by the muffler and exhaust gases could be hot enough to cause serious burns and/or ignite combustible objects.

  • Do not touch the muffler or engine. They are very HOT and will cause severe burns. Do not put body parts or any flammable or combustible materials in the direct path of the exhaust.

  • Always remove any tools or other service equipment used during maintenance away from the generator before operating.

  • Avoid skin contact with engine oil or gasoline. Wear protective clothing and equipment. Wash all exposed skin with soap and water.
    FUEL SAFETY

  • Store fuel in a container approved for gasoline.

  • Do not smoke when filling the generator with gasoline.

  • Do not allow the generator’s gas tank to overflow when filling.

  • Shut down the engine and allow it to cool for five minutes before adding gasoline or oil to the generator.

  • Never remove the fuel cap when the generator is running. Shut off the engine and allow the unit to cool at least five minutes. Remove the fuel cap slowly to release pressure, keep fuel from escaping around the cap, and to avoid the heat from the muffler igniting fuel vapors. Tighten the fuel cap securely after refueling.

  • Wipe spilled fuel from the unit.

  • Never attempt to burn off spilled fuel.

  • Never overfill the fuel tank. Leave room for fuel to expand. Overfilling the fuel tank can result in a sudden overflow of gasoline and result in spilled gasoline coming in contact with HOT surfaces.

  • Spilled fuel can ignite. If fuel is spilled on the generator, wipe up any spills immediately. Dispose of rag properly. Allow area of spilled fuel to dry before operating the generator.

  • Wear eye protection while refueling.

  • Never use gasoline as a cleaning agent.

  • Store any containers containing gasoline or LPG/propane in a well-ventilated area, away from any combustibles or source of ignition.

GASOLINE AND GASOLINE VAPOR (GAS)

DANGER
Fire and explosion hazard. Gasoline and LPG/propane are highly explosive and flammable and can cause severe burns or death.

  • In case of a gas fire, do not attempt to extinguish the flame if the fuel valve is in the gas position. Introducing an extinguisher to a generator with an open fuel valve could create an explosion hazard.
  • Gas has a distinctive odor, this will help detect potential leaks quickly.
  • Gas vapors can cause a fire if ignited.
  • Gasoline is a skin irritant and needs to be cleaned up immediately if it comes in contact with the skin.

LIQUID PETROLEUM GAS (LPG/PROPANE)

WARNING
Fire and explosion hazard. Never use a gas container, LPG/propane connector hose, LPG/propane tank or any other fuel item that appears to be damaged.

CAUTION
Fire and explosion hazard. Only use approved LPG/propane tanks with an Overfilling Prevention Device (OPD) valve. Always keep the tank in a vertical position with the valve on top and placed at ground level on a flat surface. Do not allow tanks to be near any heat source. When transporting and storing, turn the propane tank valve to the fully closed position and disconnect the tank. Make sure to always cover the generator inlet and tank outlet with protective plastic caps.

  • LPG/Propane is highly flammable and explosive.
  • Flammable gas under pressure can cause a fire or explosion if ignited.
  • LPG/Propane can settle in low places because it is heavier than air.
  • LPG/Propane has a distinctive odor added to help detect potential leaks.
  • Always keep a LPG/Propane tank in an upright position.
  • When exchanging LPG/propane tanks, be sure the tank valve is the same type.
  • In case of a LPG/propane fire, do not attempt to extinguish unless the fuel supply can be shut off safely.
  • LPG/propane will burn the skin. Prevent skin contact at all times.
  • Keep the propane tank away from the generator exhaust.
  • Large (500–1000 gallon) LPG/propane tanks will require a certified plumber to install the fuel line to the generator and the loose regulator is not used (the regulator that is attached to the fuel tank). The pressure as measured at the regulator mounted to the generator must be 7” to 14” of water column. A certified plumber must ensure that the pressure is correct or install a step down regulator if needed.

WARNING
Fire and explosion hazard. If there is a strong smell of propane while operating the generator, fully close the LPG/propane tank valve immediately. Once the propane is off, use soapy water to check for leaks on the hose and connections on the tank valve and the generator. Do not smoke or light a cigarette or check for leaks using any open flame source such as a match or lighter. If a leak is found, contact a qualified technician to inspect and repair the LPG/propane system before using the generator.

When starting the generator:

  • Make sure that the fuel cap, air filter, spark plug, fuel lines, and exhaust system are properly in place.
  • If you spill any gasoline on the tank, allow it to fully evaporate before operating.
  • Make sure the generator and LPG/propane tank are on a flat surface before operating.
  • If there is a propane odor do not start the unit because there may be a potential leak. Never place a LPG/propane tank near the engine exhaust.

When transporting or servicing the generator:

  • Make sure the LPG/propane tank and LPG/propane hose are not attached to the generator.
  • Disconnect the spark plug wire to prevent accidental starting.

When storing the generator:

  • Store away from sparks, open flames, pilot lights, heat, and other sources of ignition.
  • Do not store gas or a LPG/propane tank near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.
SAFETY LABELS AND DECALS

Westinghouse iGen4500DF Digital Inverter Generator-4
Westinghouse iGen4500DF Digital Inverter Generator-45 Westinghouse iGen4500DF Digital Inverter
Generator-6

COMPONENTS

GENERATOR COMPONENTS

Westinghouse iGen4500DF Digital Inverter Generator-7

  1. Fuel Cap: Add unleaded fuel here. Close the cap until it clicks.
  2. Engine Service Cover: Cover provides access to the engine, air cleaner, carburetor, and spark plug.
  3. Transport Wheels: Wheels allow one-handed maneuverability when used with the extendable handle.
  4. Extendable Handle: Extend and retract the handle by pushing the locking button.
  5. Carry Handles: Built-in handles allow easy, two-person transport.
  6. Recoil Handle: Pull the recoil handle to manually start the engine.
  7. Control Panel: The control panel contains the outlets and operational controls.
  8. Oil Access Cover: Cover provides access to the oil fill cap/dipstick and oil drain plug.
  9. Battery Access Cover: Cover provides access to the battery and quick-connect plug.
  10. Muffler and Spark Arrestor: The spark arrestor prevents sparks from exiting the muffler.
  11. Model Information Label: Provides model serial number, voltage/amps, and power rating information.

DIGITAL DATA CENTER
Fuel remaining and power output percentage LEDs are continuously displayed. Push the Mode button to cycle through the data display modes.

Westinghouse iGen4500DF Digital Inverter Generator-8

COMPONENTS

CONTROL PANEL COMPONENTS

Westinghouse iGen4500DF Digital Inverter Generator-9

  1. 120 Volt AC, 20 Amp Duplex NEMA 5-20R Receptacle: Receptacle can supply a maximum of 20 Amps.
  2. Ground Terminal: The ground terminal is used to externally ground the generator.
  3. Parallel Operation Outlets: A compatible Westinghouse Inverter Generator can be connected for additional power output.
  4. LED Data Center: Displays remaining run time (F), power output in kW (P), fuel level in liters (L), voltage output (V), and lifetime hours.
  5. Overload Reset: The generator inverter will automatically switch OFF all AC output to protect the generator if overloaded or if there is a short circuit in a connected appliance.
  6. USB Ports: Two-port 5V/2.1A USB outlet. Accepts Type A USB plugs.
  7. Low Oil LED: Indicates low oil level. When the oil level in the crankcase falls below the safe operating limit, the low oil level indicator will illuminate and the generator will automatically shut off the engine.
  8. Overload LED: Indicates that the generator is overloaded. See page 17.
  9. Output Ready LED: Illuminates when the generator is operating normally. Indicates the generator is producing electrical power at the receptacles.
  10. Fuel Selector Switch: Used to select gas or propane operation.
  11. LPG/Propane Inlet: Connects a propane tank with the included LPG/propane hose.
  12. Battery Charging Port: Used to charge the battery with the included battery charger.
  13. Battery Indicator: Indicates that battery power is ON. Light will remain illuminated while the unit is ON.
  14. Eco Mode: Eco mode minimizes fuel consumption and noise by adjusting the engine RPM to the minimum required for the current load.
  15. Push-Button Start/Stop: Push once to automatically start the engine. Push again to stop the engine.
  16. Battery Switch: Turns battery ON and OFF. Must be ON before electric start or remote start.
  17. Main Circuit Breaker: The main circuit breaker controls total output of all outlets to protect the generator from overload or short circuit.
  18. 20 Amp AC Circuit Breaker: Circuit breaker limits the current that can be delivered through the NEMA 5- 20R receptacle to 20 Amps.
  19. 30 Amp AC Circuit Breaker: Circuit breaker limits the current that can be delivered through the NEMA TT-30 receptacle to 30 Amps.
  20. 120 Volt AC, 30 Amp NEMA TT-30R Receptacle: Receptacle can supply a maximum of 30 Amps.
ASSEMBLY

CAUTION
Weight hazard. Always have assistance when lifting the generator.

  1. Carefully open the carton.
  2. Remove and save the instruction manual, oil bottle, oil funnel, LPG/propane hose, spark plug socket wrench, and battery charger.
  3. Remove and discard the packing tray.
  4. Unfold the top of the plastic bag enclosing the generator.
  5. Carefully cut the vertical corners of the carton to access the generator.
  6. Recycle or dispose of the packaging materials properly.
CARTON CONTENTS
  • User manual
  • Quick Start Guide/Maintenance Schedule
  • LPG/propane hose with regulator
  • Remote start key fob (attached to recoil starter)
  • 0.63 Quart (0.6 Liter) bottle of SAE 10W-30 Oil
  • Battery charger
  • Spark plug socket wrench
  • Oil Funnel
  • Screwdriver

If any parts are missing, contact our service team at service@wpowereq.com or call 1-855-944-3571.

INITIAL OIL FILL

NOTICE
THIS GENERATOR HAS BEEN SHIPPED WITHOUT OIL. Do not attempt to crank or start engine before it has been properly serviced with recommended oil. Failure to add engine oil before starting will result in serious engine damage.

Use of 2-stroke/cycle oil or other unapproved oil types can cause severe engine damage that is not covered under warranty. Use of 2-stroke/cycle oil or other unapproved oil types can cause severe engine damage that is not covered under warranty.

The included, recommended oil type for typical use is 10W-30 engine oil. If running the generator in extreme temperatures, refer to the following chart.

Westinghouse iGen4500DF Digital Inverter Generator-10

  1. On a level surface, remove the oil access cover and oil dipstick.

  2. Using the supplied funnel and oil, add oil into the engine.
    Note: As residual oil from the factory may remain in the engine, add the oil incrementally near the end of the bottle to prevent overfilling the engine. See Engine Oil Level Check in the Maintenance section.

  3. Replace the oil dipstick and hand-tighten.

  4. Replace the oil access cover.

FUEL

WARNING
Fire and explosion hazard. Never use a gasoline container, gasoline tank, propane connector hose, propane tank, or any other fuel item that is broken, cut, torn or damaged.

DANGER
Fire and explosion hazard. Do not overfill fuel tank. Fill only to the red fill ring located in the in-tank fuel screen filter. Overfilling may cause fuel to spill onto engine causing a fire or explosion hazard.

Fire and explosion hazard. Never refuel the generator while the engine is running. Always turn the engine off and allow the generator to cool for two minutes before refueling.

NOTICE

| Do not use E15 or E85 fuel in this product. Engine or equipment damage caused by stale fuel or the use of unapproved fuels (such as E15 or E85 ethanol blends) is not covered by warranty. Only use unleaded gasoline containing up to 10% ethanol.

FUEL REQUIREMENTS
  • CLEAN, FRESH, unleaded gasoline, 87–93 octane.
  • Up to 10% ethanol (gasohol) is acceptable (where available; non-ethanol fuel is recommended).
  • DO NOT use E85 or E15.
  • DO NOT use a gas oil mix.
  • DO NOT modify the engine to run on alternate fuels.
  • DO NOT fuel indoors.
  • DO NOT create a spark or flame while fueling.

USING FUEL STABILIZER
Adding a fuel stabilizer (not included) extends the usable life of fuel and helps prevent deposits from forming that can clog the fuel system. Follow the manufacturer’s instructions for use.
Always mix the correct amount of fuel stabilizer to gasoline in an approved gasoline container before fueling the generator. Run the generator for five minutes to allow the stabilizer to treat the entire fuel system.

FILLING THE FUEL TANK

  1. Turn the generator OFF and allow to cool for a minimum of two minutes before fueling.

  2. Place the generator on level ground in a well ventilated area.

  3. Clean area around fuel cap and remove the cap slowly.
    NOTICE
    Only fill the tank from an approved gasoline container. Make sure the gasoline container is internally clean and in good condition to prevent fuel system contamination

  4. Slowly add the recommended fuel. Do not overfill. Fill.
    only to the red maximum fill ring on the fuel screen filter visible in the filler neck.

  5. Install the fuel cap and tighten until a click is heard.

NOTICE
Fuel can damage paint and plastic. Use caution when filling the fuel tank. Damage caused by spilled fuel is not covered under warranty.

Clean the fuel screen filter of debris before and after each fueling. Remove the fuel screen filter by slightly compressing it while removing it from the fuel tank.

CONNECT AN LPG/PROPANE TANK

NOTICE

  • The LPG/propane tank can be of any capacity but the tank must conform to the standard as listed in Fuel Safety section.
  • Propane tanks that use liquid withdrawal system can not be used on these models.
  • Verify the re-qualification date on the tank has not expired.
  • Do not use included LPG/propane hose for any other appliances.

NOTICE

  • All new tanks must be purged of air and moisture prior to filling. Used tanks that have not been plugged or kept closed must also be purged. The purging process should be done by a propane supplier (Tanks from an exchange supplier should have been purged and filled properly).
  • Always position the tank so the connection between the valve and the gas inlet will not cause sharp bends or kinks in the hose.

WARNING
Explosion hazard. Do not start generator if you smell LPG. Always fully close the propane tank valve and disconnect the LPG/propane hose from the generator when not in use.

  1. Turn the generator OFF and place on a flat surface in a well ventilated area.

  2. Verify that the propane tank valve is in the fully closed position.

  3. Remove the cover on the generator propane inlet valve.

  4. Use your fingers to hand thread the LPG/propane hose (included) to the propane inlet on the generator.
    IMPORTANT: DO NOT use thread seal tape or any other type of sealant to seal the LPG/propane hose connection.

  5. Tighten the LPG/propane hose connector to the generator with a 19 mm or adjustable wrench. DO NOT over-tighten.
    Torque: 5-10 lb-ft.

  6. Remove the safety plug or cap from the propane tank valve.

  7. Attach the other end of the hose to the LPG/propane connector on the tank and hand tighten.

  8. Turn the propane tank valve to the fully open position. Check all connections for leaks by wetting the fittings with a solution of soap and water. Bubbles which appear or bubbles which grow indicate that a leak exists. If a leak exists at a fitting, turn the propane tank valve to the fully closed position and tighten the fitting. Turn the valve back on and recheck the fitting with the soap and water solution. If the leak continues or if the leak is not at a fitting then do not use the generator and contact customer service.

CONNECT THE BATTERY

  1. Push down the battery access cover tab and pull the cover forward to remove it.

  2. Verify that the rubber battery strap is firmly securing the battery in place. If loose, pull on the strap and hook it onto the mounting base.
    Note: If the strap is loose behind the battery, remove the battery, reconnect the strap, replace the battery, then thread the strap under the battery quick connect cables.

  3. A quick-connect battery plug is preinstalled on the battery. Remove the cable tie securing the plugs then push firmly to connect them.

  4. Align the tabs on the bottom of the battery access cover with the generator case then push to reinstall the cover.
    Note: The generator is equipped with a battery charging feature. Once the engine is running, a small charge will slowly recharge the battery.

OPERATION

OPERATION
GENERATOR LOCATION
Read and understand all safety information before starting the generator.

Westinghouse iGen4500DF Digital Inverter Generator-18

NEVER operate the generator inside any building, including garages, basements, crawlspaces, sheds, enclosure, or compartment, including the generator compartment of a recreational vehicle.

DANGER
Electrocution hazard. Never use the generator in a location that is wet or damp. Never expose the generator to rain, snow, water spray, or standing water while in use. Protect the generator from all hazardous weather conditions. Moisture or ice can cause a short circuit or other malfunction in the electrical circuit. Using a generator or electrical appliance in wet conditions, such as rain or snow, or near a pool or sprinkler system, or when your hands are wet, could result in electrocution.

WARNING
Fire hazard. Only operate the generator on a solid, level surface. Operating the generator on a surface with loose material such as sand or grass clippings can cause debris to be ingested by the generator that could block cooling vents or the air intake system. Allow the generator to cool for 30 minutes before transport or storage.

The generator should be on a flat, level surface at all times (Even while not in operation). The generator must have at least 5 ft. (1.5 m) of clearance from all combustible material.
Do not operate the generator in the back of a SUV, camper, trailer, truck bed (regular, flat, or otherwise), under stairs, next to walls or buildings, or in any other location that will not allow for adequate cooling of the generator and/or the muffler. DO NOT contain generators during operation.

DANGER
Asphyxiation hazard. Place the generator in a well-ventilated area. DO NOT place the generator near vents or intakes where exhaust fumes could be drawn into occupied or confined spaces. Carefully consider wind and air currents when positioning generator.

GROUNDING

WARNING
Shock hazard. Failure to properly ground the generator can result in electric shock.

The generator neutral is floating. The generator ground terminal is connected to the frame of the generator, the metal non-current-carrying parts of the generator, and the ground terminals of each receptacle. The generator (stator winding) is isolated from the frame and from the AC receptacle ground pin. Electrical devices that require a grounded receptacle pin connection may not function properly.

If this generator will be used only with cord and plug equipment connected to the receptacles mounted on the generator, National Electric Code does not require that the unit be grounded. However, other methods of using the generator may require grounding to reduce the risk of shock or electrocution.
Before using the ground terminal, consult a qualified electrician, electrical inspector, or local agency having jurisdiction for local codes or ordinances that apply to the intended use of the generator.

NOTICE
Only use grounded 3-prong extension cords, tools, and appliances, or double- insulated tools and appliances.

HIGH ALTITUDE OPERATION
Engine power is reduced the higher you operate above sea level. Output will be reduced approximately 3.5% for every 1000 feet of increased altitude from sea level.
High altitude adjustment is required for operation at altitudes over 2000 ft. (762 m). Operation without this adjustment will cause decreased performance, increased fuel consumption, and increased emissions. Operation of the engine at altitudes below 2,000 ft. (762 m) with the high altitude kit is not recommended.

High Altitude Carburetor Kit: Part# 518916- 01
High Altitude DF Regulator
Manufactured before 7/19: Part# 518918
Manufactured 7/19 and later: Part# 518918- 01

Note: You must purchase both the Dual Fuel Regulator and Carburetor Kit for proper high altitude operation.

REMOTE START

WARNING
Verify that the area around the generator is clear before remote starting the generator.

The remote start key fob included with the generator should be attached to the recoil handle or control panel. If your unit was shipped without a key fob, contact Westinghouse customer service.
The generator can be started remotely from up to 99 feet (30 meter) using the remote start key fob.
Note: As the batteries in the remote start key fob drain,
operational distance will decrease.
Remote replacement batteries: (2) CR2016

REPROGRAMMING THE REMOTE START
If the remote start key fob is replaced or needs re-paired to the generator, follow this procedure.

  1. Turn the generator battery switch to the ON position.

  2. Push and hold the ON/OFF button for 10 seconds, then release. The start indicator light will flash green.

  3. Push the ON button on the remote start key fob. It will pair with generator automatically and the start indicator light on the generator will stop flashing.

FUEL SELECTOR SWITCH
Position the fuel selector switch on the front control panel to the desired fuel choice.
Turn the fuel selector switch fully to the right for gasoline operation.

Turn the fuel selector switch fully to the left for propane operation.

BREAK-IN PERIOD
For proper break-in, do not exceed 50% of the rated running watts (1850 watts) during the first five hours of operation.
Vary the load occasionally to allow stator windings to heat and cool and help seat the piston rings.

BEFORE STARTING THE GENERATOR
Verify that:

  • The generator is placed in an safe, appropriate location.
  • The generator is on a dry, flat, and level surface.
  • The engine is filled with oil.
  • All loads are disconnected.
  • The ECO switch is in the OFF position.

DANGER
Fire and explosion hazard. DO NOT move or tip the generator during operation.

STARTING THE ENGINE: GASOLINE
  1. Verify that fuel is in the gas tank.
  2. Turn the fuel selector switch to gasoline operation.
  3. Push the battery switch to the ON position.
  4. Choose the starting method:
    a. Recoil Start: Firmly grasp and pull the recoil handle slowly until you feel increased resistance, then pull rapidly.
    b. Remote Start: Push and hold the ON button on the remote start key fob for one second.
    c. Push-Button Start: Push and hold the engine start button for two seconds.

STARTING THE ENGINE: LPG

DANGER
Fire and explosion hazard. Always turn the propane tank valve to the fully closed position if not running the generator on propane.

  1. Make sure the LPG/propane hose is correctly connected to the generator and propane tank.
  2. Turn the fuel selector switch to propane operation.
  3. Fully open the valve on the propane tank.
  4. Push the battery switch to the ON position.
  5. Choose the starting method:
    a. Recoil Start: Firmly grasp and pull the recoil handle slowly until you feel increased resistance, then pull rapidly.
    b.Remote Start: Push and hold the ON button on the remote start key fob for one second.
    c.Push-Button Start: Push and hold the engine ON/OFF button for two seconds.
    Note: The engine will automatically set the choke and begin the start sequence. If the engine fails to start, the generator will attempt to start the engine two more times.

SWITCHING FUEL SOURCES

DANGER
Fire and explosion hazard. DO NOT add gasoline to the fuel tank or connect the LPG/propane hose to the generator while the generator is in operation.

The fuel source can be switched while the engine is running if a propane tank is connected to the generator BEFORE operation.
GASOLINE TO PROPANE

IMPORTANT: Load capacity is reduced when running on propane. Make sure the generator can supply enough (running) and surge (starting) watts for the items you are powering before switching to propane.

  1. Turn the propane tank valve to the fully open position.
  2. Turn the fuel selector switch to propane operation.

PROPANE TO GASOLINE

  1. Turn the fuel selector switch to gasoline operation.
  2. Turn the propane tank valve to the fully closed position. Note: When switching to propane operation the engine may run rough for a few seconds while it purges gasoline in the carburetor.

If the engine stops when switching fuel sources, disconnect all loads then restart the unit on the fuel source of choice.

STOPPING THE ENGINE

  1. Turn off and unplug all connected electrical loads. Never start or stop the generator with electrical devices plugged in or turned on.
  2. Let the generator run with no load for several minutes to stabilize internal temperatures of the engine and generator.
  3. Push and hold the ON/OFF button for one second or push OFF on the remote start key fob for one second.
  4. Push the battery switch to the OFF position.
  5. If operating on LPG, turn the propane tank valve to the fully closed position.

FREQUENCY OF USE
If the generator will be used on an infrequent or intermittent basis (more than one month before next use), refer to the Battery Maintenance and Storage sections of this manual for information regarding battery charging and fuel deterioration.

ECO MODE

NOTICE
Always start the generator with ECO MODE OFF. Allow the engine speed to stabilize and the OUTPUT READY LED to illuminate before switching ECO MODE ON.

Note: Do not use ECO MODE when in parallel operation with another Westinghouse generator.
ECO MODE minimizes fuel consumption and noise by adjusting the engine RPM to the minimum required for the current load.
Turn ECO MODE ON when powering small appliances with continuous loads such as a computer or electric light.
Turn ECO MODE OFF when powering large surge loads such as an air conditioner or electric pump.
To turn on ECO MODE, verify that the OUTPUT READY LED is illuminated green, then push the switch to the ON position. If no load is present, the generator RPM will drop to idle speed. The generator will detect loads as they are applied and increase engine RPM.
To run the generator at maximum power and RPM, push the ECO MODE switch to the OFF position.

AC CIRCUIT BREAKERS
The circuit breakers will automatically switch OFF if there is a short circuit or a significant overload of the generator at each receptacle. The main circuit breaker will automatically switch OFF if the combined load of the receptacles exceeds 31 Amps.
If an AC circuit breaker switches OFF automatically, check that the appliance is working correctly and it does not exceed the rated load capacity of the circuit before resetting the AC circuit breaker ON.

OVERLOAD RESET
The generator will automatically switch OFF all AC output to protect the generator if overloaded or if there is a short circuit in a connected appliance. However, the engine will continue to run. Marginal overloading that temporarily illuminates the OVERLOAD LED may shorten the service life of the generator.
OVERLOAD on the control panel will illuminate red and the green OUTPUT READY will be OFF.

To restore AC output:

  1. Turn off and unplug all connected electrical loads.
  2. Push the RESET button on the control panel until the OVERLOAD LED goes OFF and the OUTPUT READY LED is illuminated.
  3. Reset the circuit breakers if OFF.
  4. Verify that the intended running and surge loads do not exceed the generator’s capacity.
  5. Reconnect electrical loads sequentially, allowing the generator to stabilize after each load is connected.

GENERATOR CAPACITY

NOTICE
Do not overload the generator’s capacity. Exceeding the generator’s wattage/amperage capacity can damage the generator and/or electrical devices connected to it.

Make sure the generator can supply enough continuous (running) and surge (starting) watts for the items you will power at the same time.
The total power requirements (Volts x Amps = Watts) of all appliances connected must be considered. Appliance and power tool manufacturers usually list rating information near the model or serial number.

To determine power requirements:

  1. Select the items you will power at the same time.
  2. Total the continuous (running) watts of these items. This is the amount of power the generator must produce to keep the items running. See the wattage reference chart on the next page.
  3. Estimate how many surge (starting) watts you will need.
    Surge wattage is the short burst of power needed to start electric motor- driven tools or appliances such as a circular saw or refrigerator. Because not all motors start at the same time, total surge watts can be estimated by adding only the item(s) with the highest additional surge watts to the total rated watts from step 2.

Example:

Westinghouse iGen4500DF Digital Inverter Generator-24

POWER MANAGEMENT
To prolong the life of the generator and attached devices, use care when adding electrical loads to the generator. There should be nothing connected to the generator outlets before starting the engine. The correct and safe way to manage generator power is to sequentially add loads as follows:

  1. With nothing connected to the generator, start the engine as described in this manual.
  2. Plug in and turn on the first load, preferably the largest load you have.
  3. Permit the generator output to stabilize (engine runs smoothly and attached device operates properly).
  4. Plug in and turn on the next load.
  5. Again, permit the generator to stabilize.
  6. Repeat steps 4 and 5 for each additional load.

Westinghouse iGen4500DF Digital Inverter Generator-44

*Wattages listed are approximate. Verify actual wattage.

EXTENSION CORDS

WARNING
Asphyxiation hazard. Extension cords running directly into the home increase the risk of carbon monoxide poisoning through any openings. If an extension cord running directly into your home is used to power indoor items, there is a risk of carbon monoxide poisoning to people inside the home. Always use battery-powered carbon monoxide detector (s) that meet current UL 2034 safety standards when running the generator. Regularly check the detector (s) battery.

  • Asphyxiation hazard. When operating the generator with extension cords, make sure the generator is located in an open, outdoor area, far away from occupied spaces with exhaust pointed away.
  • Fire and electrocution hazard. Never use worn or damaged extension cords. Damaged or overloaded extension cords could overheat, arc, and burn resulting in death or serious injury.

Before connecting an AC appliance or power cord to the generator:

  • Use grounded 3-prong extension cords, tools, and appliances, or double-insulated tools and appliances.
  • Make sure the tool or appliance is in good working order. Faulty appliances or power cords can create a potential for electric shock.
  • Make sure the electrical rating of the tool or appliance does not exceed the rated power of the generator or the receptacle being used.

EXTENSION CORD SIZING
Only use grounded 3-prong extension cords marked for outdoor use that are rated for the electrical load.

Westinghouse iGen4500DF Digital Inverter Generator-25

PARALLEL OPERATION

WARNING
Fire and electrocution hazard. Never connect or disconnect the parallel cord leads when a generator is running.

NOTICE
Connecting the iGen4500DF to a generator that is not compatible can cause a low voltage output that can damage tools and appliances powered by the generator.

Parallel operation gives you the ability to link the iGen4500DF to a compatible Westinghouse Inverter Generator for combined running and peak power output. A Westinghouse parallel cord (purchased separately) is required for parallel operation. This cord can be purchased from an authorized Westinghouse Generator dealer.
Note: Do not use ECO MODE when in parallel operation with another Westinghouse generator.
Parallel cord (50A/6000 Watts): Part# 507PC
Note: Compatible Westinghouse generators without parallel ports can be operated in parallel with the receptacle-mounted parallel cable, Part# 260041.

  1. On both generators, make sure the battery switch and the ECO MODE switch are in the OFF position.

  2. Connect the black and red parallel cable leads to the black parallel ports on each corresponding generator control panel as shown below. Connect the black lead to the left port, the red lead to the right port.
    Note:
    DO NOT connect two red leads or two black leads into the same generator.
    Westinghouse iGen4500DF Digital Inverter Generator-26

  3. Connect the green ground lead to the ground terminal on each generator and tighten the nut.

  4. Start one of the generators and wait until the OUTPUT READY LED illuminates.

  5. Start the second generator and wait until the OUTPUT READY LED illuminates before connecting a load.

  6. Connect additional loads as described in Power Management on page 18.

  7. Unplug all loads before stopping the generators.

TRANSPORTING

CAUTION
Weight hazard. Always have assistance when lifting the generator.

  • Allow the generator to cool a minimum of 30 minutes before transporting.
  • If operating on LPG, turn the propane tank valve to the fully closed position.
  • Disconnect the LPG/propane hose from the generator and propane tank.
  • Replace all protective covers on the generator control panel.
  • Only use the generator’s fixed handle(s) to lift the unit or attach any load restraints such as ropes or tie-down straps. Do not attempt to lift or secure the generator by holding onto any of its other components.
  • Keep the unit level during transport to minimize the possibility of fuel leakage or, if possible, drain the fuel or run the engine until the fuel tank is empty before transport.
  • The generator wheels are only intended for hand transport. The wheels are not suitable for towing the generator either on or off-road.
  • Use the extendable handle for one-person, hand transport. To deploy the handle, push on the locking button and pull on the handle until it’s fully extended.
    To stow it, push on the locking button and push on the handle until it’s fully retracted. Only extend or retract the handle while the generator is OFF, stationary, and resting on a horizontal surface. Do not use the extendable handle to lift the generator entirely off the ground, tow it, or up-end it.

CAUTOIN
Fire hazard. Do not up-end the generator or place it on its side. Fuel or oil can leak and damage to the generator may occur.

MAINTENANCE

MAINTENANCE SCHEDULE
Regular maintenance will improve performance and extend the service life of the generator. Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions as noted below.Westinghouse iGen4500DF Digital Inverter
Generator-46

  1. Change oil every month when operating under heavy load or in high temperatures.

  2. Clean more often under dirty or dusty conditions.
    Replace air filter if it cannot be adequately cleaned.

  3. Recommend service to be performed by authorized Westinghouse service dealer.

MAINTENANCE REPLACEMENT PARTS

Description Part Number
Foam air filter 5691
Oil drain plug crush washer 94007
Spark arrestor 6790
Battery 511019


Spark plug

| •    Torch – F7RTC

•    NGK – BPR7ES

•    Bosch – WR5D

•    Autolite – 62

ENGINE SERVICE COVER
Remove the engine service cover to access the air filter, carburetor, and spark plug. Remove the cover screws then pull the cover straight out with both hands to prevent damage to the grommet posts on the cover.

Westinghouse iGen4500DF Digital Inverter Generator-27

AIR FILTER MAINTENANCE

WARNING
Fire hazard. Never use gasoline or other flammable solvents to clean the air filter. Use only household detergent soap to clean the air filter.

The air filter must be cleaned after every 50 hours of use or six months (frequency should be increased if the generator is operated in a dusty environment).

  1. Place the generator on a level surface and allow the engine to cool for several minutes.
  2. Remove the engine service cover.
  3. Turn the knobs on the air cleaner cover to the unlocked position. Tip the cover down to remove.

Note: The air filter element is oil-soaked. Use an appropriate cleaning container.
NOTICE
Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.

  1. Remove the foam air filter from the air cleaner housing and wash it by submerging the element in a solution of household detergent soap and warm water. Slowly squeeze the foam to thoroughly clean.
    NOTICE
    DO NOT twist or tear the foam air filter element during cleaning or drying. Only apply slow but firm squeezing action.

  2. Rinse the air filter element by submerging it in fresh water and applying a slow squeezing action. Allow the filter to dry thoroughly.

NOTICE
Do not pollute. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.

  1. Dip the foam air filter in clean engine oil then squeeze out all excess oil. The engine will smoke when started if too much oil is left in the filter.
  2. Install the foam air filter in the housing and lock the air cleaner cover in place.
  3. Install the engine service panel. Air Filter: Part# 5691
    ENGINE OIL LEVEL CHECK

CAUTION
Avoid skin contact with engine oil. Wear protective clothing and equipment. Wash all exposed skin with soap and water.

NOTICE
Always use the specified engine oil. Failure to use the specified engine oil can cause accelerated wear and/or shorten the life of the engine.

When using the generator under extreme, dirty, dusty conditions or in extremely hot weather, change the oil more frequently.
Ambient air temperature will affect engine oil performance. Change the type of engine oil used based on weather conditions.

Westinghouse iGen4500DF Digital Inverter Generator-30

Check the engine oil level before each use or every 8 hours of operation.

  1. Place the generator on a level surface and allow the engine to cool for several minutes.

  2. Remove the oil access cover.

  3. With a damp rag, clean around the oil dipstick.

  4. Remove the oil dipstick and wipe the dipstick clean.

  5. Screw the dipstick fully into the filler neck. Remove the dipstick and verify that the oil level is within safe operating range.

  6. If low, add recommended engine oil incrementally and recheck until the level is between the L and H marks on the dipstick. DO NOT overfill. If over the full mark on dipstick, drain the oil to reduce oil level to the full mark on dipstick.

  7. Replace the oil dipstick and hand-tighten.

  8. Install the oil access cover.

ENGINE OIL CHANGE

WARNING
Accidental start-up. Remove the spark plug boot from the spark plug when working on the generator. Also remove the battery quick-connect plug from the battery.

When using the generator under extreme, dirty, dusty conditions or in extremely hot weather, change the oil more frequently. Change the oil while the engine is still warm from operation.

  1. Place the generator on a level surface and allow the engine to cool for several minutes.

  2. Remove the engine service cover. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact the spark plug.

  3. Remove the oil access cover.

  4. With a damp rag, clean around the oil dipstick. Remove the dipstick and wipe clean.

  5. Remove the rubber plug under the oil drain bolt and place an oil pan (or suitable container) under the drain hole.

  6. Using a 10mm wrench, remove the oil drain bolt and allow the oil the to drain.

  7. Install the oil drain plug and tighten securely. Install the rubber plug.
    Note: A new oil drain plug crush washer is recommended at each oil change.
    Drain plug crush washer: Part# 94007

  8. Slowly pour oil into the oil fill opening until oil the level is between the L and H marks on the dipstick. Stop frequently to check the oil level. DO NOT overfill.
    Maximum oil capacity: 0.63 US qt (0.60 L)

  9. Replace the dipstick and hand-tighten.

  10. Connect the spark plug wire and install the engine service cover.

NOTICE
Do not pollute. Follow the guidelines of the EPA or other governmental agencies for proper disposal of hazardous materials. Consult local authorities or reclamation facility.

SPARK PLUG MAINTENANCE
Inspect and clean the spark plug after every 100 hours of use or six months. Replace the spark plug after 300 hours of use or every year.

  1. Place the generator on a level surface and allow the engine to cool.

  2. Remove the engine service cover.

  3. Remove the spark plug boot by firmly pulling the spark boot directly away from the engine.

  4. Clean the area around the spark plug.

  5. Remove the spark plug with the included spark plug socket wrench.
    NOTICE
    Never apply any side load or move the spark plug laterally when removing the spark plug.

  6. Inspect the spark plug. Replace if electrodes are pitted, burned, or the insulator is cracked. Only use a recommended replacement plug.
    Recommended Spark Plug Replacement Westinghouse Model Number|


Torch

| ****

NGK

| ****

Bosch

| ****

Autolite

---|---|---|---|---
iGen4500DF| F7RTC| BPR7ES| WR5D| 62
7. Measure the spark plug electrode gap with a wire-type feeler gauge. If necessary, correct the gap by carefully bending the side electrode.
Spark plug gap: 0.024 – 0.032 in. (0.60 – 0.80 mm)

  1. Carefully install the spark plug finger tight, then tighten as additional 3/8 to 1/2 turn with the spark plug wrench.
  2. Install the spark plug boot and engine service cover.

Westinghouse iGen4500DF Digital Inverter Generator-34 SPARK ARRESTOR SERVICE
Check and clean the spark arrestor after every 100 hours of use or six months. Failure to clean the spark arrestor will result in degraded engine performance.

  1. Place the generator on a level surface and allow the muffler to cool before servicing the spark arrestor.

  2. Remove the cover screws and the muffler cover. Use a screw driver to remove the spark arrestor.

  3. Carefully remove the carbon deposits from the sparkarrestor screen with a wire brush. The spark arrestor must be free of breaks and tears. Replace the spark arrestor if damaged.
    Spark Arrestor: Part# 6790

  4. Reinstall the spark arrestor and muffler cover.

BATTERY MAINTENANCE

The battery shipped with the generator has been fully charged. A battery may lose some charge when not in use for prolonged periods of time. If the battery is unable to crank the engine, plug the included 12V charger into the battery charging port on the control panel.

Note: If the generator is not run, charge the battery overnight once a month.
The supplied battery charger is not a trickle charger and is not intended for continuous use. Do not use the battery charger for more than 8 hours (overnight) to prevent overcharging the battery.
Note: Once started, the generator will charge the battery after 30–60 minutes of use. If you do not regularly run the generator, charge the battery overnight once a month to keep it ready for use. Charge the battery in a dry location.

  1. Plug the charger into the battery charging port on the control panel. Plug the wall receptacle end of the battery charger into a 120 Volt AC wall outlet.
  2. Unplug the battery charger from wall outlet and control panel jack after 8 hours of charging.

BATTERY REPLACEMENT
Battery, 12V/6.5 Ah: Part# 511019

WARNING
Burn hazard. The battery contains sulfuric acid (electrolyte) which is highly corrosive and poisonous.
Wear protective clothing and eye protection when working near the battery. Keep children away from the battery.

CAUTION
Battery posts, terminals contain lead and lead compounds. Wash hands after handling.

  1. Remove the battery access cover.
  2. Remove the quick-connect plug and remove the battery strap. Remove the battery from the unit.
  3. Disconnect the quick-disconnect cable leads from the battery.
  4. On the replacement battery, connect the white (-) quick-connect cable to the battery negative terminal. Slide the rubber boot over the connection hardware.
  5. Connect the red (+) quick-connect cable to the battery positive terminal. Slide the rubber boot over the connection hardware.
  6. Lift the battery strap and install the battery into the generator. Thread the battery strap under the quick-connect cables and secure it on the mounting base.
  7. Connect the quick-connect plug and install the battery access cover.

NOTICE
Dispose of the used battery properly according to the guidelines established by your local or state government.

STORAGE
Proper storage preparation is required for trouble-free operation and generator longevity.

NOTICE
Gasoline stored for as little as 30 days can deteriorate, causing gum, varnish, and corrosive buildup in fuel lines, fuel passages and the engine. This corrosive buildup restricts the flow of fuel, which can prevent the engine from starting after a prolonged storage period. The use of fuel stabilizer significantly increases the storage life of gasoline. Full-time use of fuel stabilizer is recommended. Follow the manufacturer’s instructions for use.

STORAGE TIME RECOMMENDED PROCEDURE
Less than 1 month No service required.

2 to 6 months

| Fill with fresh gasoline and add gasoline stabilizer. Drain the carburetor float bowl.
6 months or longer| Drain the fuel tank and carburetor

float bowl.

SHORT TERM STORAGE

  • Allow the generator to cool a minimum of 30 minutes before storage.

  • If operating on LPG, turn the propane tank valve to the fully closed position and disconnect the LPG/propane hose from the generator and propane tank.
    Replace all protective covers on the generator control panel.
    Wipe the generator with a moist cloth. Clean any debris from the air inlets under the control panel and muffler cooling vents.

  • Store the generator in a well-ventilated, dry location away from sparks, open flames, pilot lights, heat, and other sources of ignition such as areas with a spark-producing electric motor or where power tools are operated.

  • Do not store the generator, gasoline, or propane tanks near furnaces, water heaters, or any other appliances that produce heat or have automatic ignitions.

  • With the engine and exhaust system cool and all surfaces dry, cover the generator to keep out dust. Do not use a plastic sheet as a dust cover. Non-porous materials trap moisture and promote rust and corrosion.

LONG TERM STORAGE
Even properly stabilized fuel can leave residue and cause corrosion if left long term. If storing the generator for two to six months, drain the float bowl to prevent gum and varnish buildup in the carburetor.

DRAINING THE FLOAT BOWL

  1. Remove the engine service cover.

  2. Locate the drain hose extending from the bottom of the carburetor float bowl.

  3. Place the loose end of the hose outside the generator into an approved gasoline container to catch the drained fuel.

  4. Loosen the float bowl drain screw and allow the fuel to drain. Tighten the float bowl drain screw.

  5. Route the drain hose between the air cleaner housing and the engine service cover. Install the engine service cover.

DRAINING THE FUEL TANK
If storing the generator for longer than six months, drain the fuel tank to prevent fuel separation, deterioration, and deposits in the fuel system.

  1. Unscrew the fuel tank cap. Remove the fuel screen filter by slightly compressing it while removing it from the tank.
  2. Using a commercially available gasoline hand pump (not included), siphon the gasoline from the fuel tank into an approved gasoline container. DO NOT use an electric pump.
  3. Reinstall the fuel screen filter and the fuel tank cap.
  4. Start the generator and allow it to run until the generator engine stops.
  5. Push the battery switch to the OFF position.
  6. Disconnect the battery quick-connect plug.
  7. Remove the spark plug.
  8. Put a teaspoon of engine oil into the cylinder and pull the recoil handle until resistance is felt. At this position the piston is coming up on its compression stroke and both valves are closed. Storing the engine in this position will help prevent internal corrosion. Return the recoil handle gently.
  9. Reinstall the spark plug. Leave the spark plug boot disconnected to prevent accidental starting.
  10. Install the engine service cover.

VALVE CLEARANCE

NOTICE
Checking and adjusting valve clearance must be done when the engine is cold.

  1. Remove the rocker arm cover and carefully remove the gasket. If the gasket is torn or damaged, it must be replaced.

  2. Remove the spark plug so the engine can be rotated more easily.

  3. Rotate the engine to top dead center (TDC) by pulling the recoil handle slowly. Looking through the spark plug hole, the piston should be at the top (both valves are closed).

  4. Both the rocker arms should be loose at TDC on the compression stroke. If they are not, rotate the engine 360°.

  5. Insert a feeler gauge between the rocker arm and the valve stem to measure valve clearance.
    Westinghouse iGen4500DF Digital Inverter Generator-47

  6. If an adjustment is necessary, hold the rocker arm pivot and loosen the pivot adjusting nut.

  7. Turn the rocker arm pivot to obtain the specified clearance. Hold the rocker arm pivot and re-tighten the pivot adjusting nut to the specified torque.
    Torque: 106 inch-pound (12 N•m)

  8. Perform this procedure for the other valve.

  9. Install the gasket, rocker arm cover, and spark plug.

MANUALLY SET THE CHOKE
If the battery is dead or disconnected, you may need to set the choke by hand for proper operation.

  1. Remove the engine service cover.

  2. Locate the small black choke lever on top of the carburetor.

  3. To close the choke for cold starting: Use a screwdriver to push the black lever toward the front of the generator.
    Westinghouse iGen4500DF Digital Inverter Generator-39

  4. Start the generator. The start-up sequence should automatically open the choke. If the choke does not open automatically, push the choke manually to open it.

NOTICE
Certain ambient temperatures and environments may require you to close the choke halfway for a successful start.

TROUBLESHOOTING

PROBLEM POSSIBLE CAUSE CORRECTION
Engine will not start Battery switch in the OFF position. Turn battery

switch to the ON position.
Out of fuel.| Refuel.
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline.| Drain the fuel tank. Refuel with fresh gasoline.
Dirty air filter.| Clean the air filter.
Low engine oil level stopped generator.| If low oil LED illuminated, turn battery switch to the OFF position. Add engine oil.
Spark plug wet with fuel (flooded engine).| Wait five minutes. Turn battery switch to the OFF position. Pull recoil handle rapidly several times. If the generator does not start, remove spark plug and dry.
Spark plug faulty, fouled, or improperly gapped.| Gap or replace the spark plug. Reinstall.
Fuel filter restricted, fuel system malfunction, fuel

pump failure, ignition malfunction, valves stuck, etc.

| Contact Westinghouse customer service toll- free at 1 855-944-3571.
Battery drained.| Use the recoil handle to start the generator.
Charge the battery.
Choke partially open or closed due to weak or disconnected battery.| Manually set the choke. See Maintenance section.
Engine starts, then shuts down| Out of fuel.| Refuel.
Incorrect engine oil level.| Check engine oil level.
Dirty air filter.| Clean the air filter.
Contaminated fuel.| Drain the fuel tank. Refuel with fresh gasoline.
Defective low oil level switch.| Contact Westinghouse customer service toll- free at 1 855-944-3571.
Engine lacks power| Air filter restricted.| Clean or replace air filter.
Bad fuel, generator stored without treating or draining gasoline, or refueled with bad gasoline.| Drain the fuel tank. Refuel with fresh gasoline.
Fuel filter restricted, fuel system malfunction, fuel

pump failure, ignition malfunction, valves stuck, etc.

| Contact Westinghouse customer service toll- free at 1 855-944-3571.
Engine runs rough or bogs when load applied| Dirty air filter.| Clean the air filter.
Generator overloaded.| Unplug some devices.
Faulty power tool or appliance.| Replace or repair tool or appliance. Stop and restart the engine.
Fuel filter restricted, fuel system malfunction, fuel

pump failure, ignition malfunction, valves stuck, etc.

| Contact Westinghouse customer service toll- free at 1 855-944-3571.
No power at AC receptacles| OUTPUT READY LED is OFF and OVERLOAD LED

is ON.

| Check AC load. Stop and restart engine.
Check the air inlet. Stop and restart the engine.
AC circuit breaker/s tripped.| Check AC loads and reset circuit breaker/s.
Faulty power tool or appliance.| Replace or repair tool or appliance. Stop and restart the engine.
Faulty generator.| Contact Westinghouse customer service toll- free at 1 855-944-3571.
PROBLEM| POSSIBLE CAUSE| CORRECTION
---|---|---







Frost on the propane tank or regulator

| If the temperature of the propane tank drops below the dew point, condensation on the tank may turn to frost or ice. This typically occurs in humid conditions.| Providing all the propane fuel handling equipment is functioning normally, no correction is needed.



The Propane tank is not equipped with an Overfilling

Prevention Device (OPD).

| If you suspect your propane fuel tank is not equipped with an OPD device, discontinue operation immediately and replace the propane fuel tank with a propane tank equipped with a an OPD.



Propane fuel tank overfilled.

| If you suspect your propane fuel tank has been overfilled, discontinue operation immediately and return the propane fuel tank to the place of purchase or refilling.








Propane fuel smell

| Fuel regulator or fuel hose and fittings not securely

sealed.

| Using a soap solution check each connection and tighten as needed.





Propane fuel regulator vent active.

| The propane fuel regulator is equipped with a vent that will allow a small amount of propane fuel vapor to escape from the regulator when the propane tank valve is opened. This can be normal providing the venting of the propane is brief. If you suspect that this is abnormal, immediately discontinue use and have the propane regulator inspected by a qualified technician.
Residual fuel from the carburetor dispersing after operation.| ****

Normal, no correction is needed.





Poor performance or engine stalling on Propane

| Propane fuel line kinked or crushed.| Inspect propane fuel line and remove kinks or other obstructions.
Fuel selector valve not properly positioned.| Rotate the fuel valve fully until the pointer is directly in line with the desired fuel.



Gasoline not purged from the carburetor before switching to propane.

| Close the propane fuel tank valve. Move the fuel selector switch to gas. Start the engine and allow the engine to run until the gasoline has been consumed in the carburetor. Begin propane start up procedure.

EXPLODED VIEWS AND PARTS LISTS

ENGINE EXPLODED VIEW

Westinghouse iGen4500DF Digital Inverter Generator-41

ENGINE PART NUMBERS

NO. PART # DESCRIPTION
1 91347 BOLT M8X30
2 93507 CRANKSHAFT OIL SEAL
3 245601-295 DIPSTICK
4 240116 CRANKCASE COVER
5 96041 CRANKCASE SEAL WASHER
6 240904 CRANKCASE LOCATING PIN
7 93010 BEARING
8 240364 CRANKSHAFT ASSEMBLY
9 332003 CAMSHAFT ASSEMBLY
10 246103 VALVE TAPPET
11 241901 PUSH ROD
12 91329 BOLT M6X16
13 245113 OIL SENSOR
14 330202 CRANKCASE
15 94007 OIL DRAIN BOLT WASHER
16 91816 OIL DRAIN BOLT
17 97447 STARTER MOTOR ASSEMBLY
18 94407 FUEL HOSE CLIP ?10.5
19 331500 CONNECTING ROD ASSEMBLY
20 245503 PISTON PIN
21 241211 PISTON
22 241301 PISTON PIN RETAINING RING
23 241607 PISTON RING ASSEMBLY
24 241021 CYLINDER HEAD
25 96182 AIR INLET GASKET
26 91029 AIR INLET STUD BOLT
27 96051 CARBURETOR SEALING GASKET
28 96058 CYLINDER HEAD SEALING GASKET
29 240905 CYLINDER HEAD LOCATING PIN
30 91007 AIR OUTLET STUD BOLT
31 96055 AIR OUTLET SEALING GASKET
32 92219 SCREW M4*20
33 249919 PLUG
34 339915 POLYURETHANE SCREEN
35 91359 BOLT M8X60
36 97109 SPARK PLUG
37 241704 AIR INLET VALVE
38 245904 AIR OUTLET VALVE
39 241806 AIR INLET VALVE SPRING LOWER HOLDER
40 246001 VALVE SPRING
41 241801 AIR INLET VALVE SPRING HOLDER
42 241802 AIR OUTLET VALVE SPRING HOLDER
43 241804 TOP CAP
44 242202 RESTRICTER PLATE ASSEMBLY
45 91818 ROCKING ARM TIGHTENING BOLT
46 242101 ROCKING ARM
47 96200 CYLINDER HEAD COVER SEALING GASKET
NO. PART # DESCRIPTION
--- --- ---
48 241115 CYLINDER HEAD COVER
49 241116 INNER COVER OF CYLINDER HEAD COVER
50 91325 BOLT M6X12
51 330501 STARTER COVER ASSEMBLY
51.1 5324 STARTER RECOIL
52 91864 STARTER PULLEY TIGHTENING BOLT
53 334501 STARTER PULLEY
54 90003 FLYWHEEL NUT M14
55 334601 IMPELLER
56 500191 ROTOR
57 91400 BOLT M6X60
58 503410 STATOR
59 337001 RESONANT CAVITY ASSEMBLY
59.1 5697 FOAM ELEMENT
60 95602 BLAST PIPE
61 90016 NUT M6
62 94226 STEEL WASHER
63 332801 CARBURETOR ASSEMBLY
64 249925 STEPPER MOTOR BRACKET
65 92055 SCREW M4X25
66 249949 STEPPER MOTOR
67 249950 STEPPER MOTOR
68 92240 BOLT M4*6
69 249934 WATERPROOF COVER
70 332301 CARBURETOR CONNECTING BLOCK
71 332901 AIR CLEANER ASSEMBLY
71.1 5691 AIR FILTER ELEMENT
72 95918 CONNECTING PIPE
73 91330 BOLT M6X20
74 249917 BRACKET
75 240511 PROTECTING COVER
76 339902 TRIGGER
77 330503 AIR DEFLECTOR
78 339903 IGNITION COIL MOUNTING BRACKET
79 339909 IGNITION COIL
80 330502 UPPER AIR DEFLECTOR
81 91334 BOLT M6X30
82 244306 CENTRIFUGAL FAN HOUSING.
83 244304 CENTRIFUGAL COVER PLUG
84 91343 BOLT M8*16
85 244606 IMPELLER
86 334302 CENTRIFUGAL FAN COVER
87 243782 MUFFLER
87.1 6790 SPARK ARRESTER
88 94216 FLAT WASHER
89 94206 SPRING WASHER
90 90011 NUT M8
NO. PART # DESCRIPTION
--- --- ---
91 500057 MUFFLER OUTER COVER
92 249914 WIRE CLIP
93 335803 TEMPERATURE SENSOR
94 599601 METAL CLAMP
95 91831 OIL DRAIN SOLENOID
96 94035 OIL DRAIN BOLT WASHER
97 91322 BOLT M5*12
98 91333 BOLT M6*28
99 91419 BOLT M8125
GENERATOR EXPLODED VIEW

Westinghouse iGen4500DF Digital Inverter Generator-42

GENERATOR PART NUMBERS

NO. PART # DESCRIPTION
1 503001 BRACKET
2 503002 BRACKET
3 503003 BRACKET
4 90027 SQUARE NUT
5 503004 ISOLATION PAD
6 90044 NUT M8
7 91325 BOLT M6X12
8 503005-332 LEFT FRAME
9 503006 UPRIGHT POST
10 503007 UPRIGHT POST
11 503008 BRACKET
12 503009 HANDLE
13 503068L FUEL TANK ASSEMBLY
14 500008 FUEL TANK ISOLATION PAD B
15 503011 BRACKET
16 503042 BRACKET
17 503147 INVERTER MODULE
18 503013 BRACKET
19 91322 BOLT M5×12
20 91345 BOLT M8X20
21 503016 CONTROL PANEL REAR COVER
22 503017 BRACKET
23 503062 FUEL SWITCH
24 503018L FUEL PIPE
25 503019L FUEL PIPE
26 503020L FUEL PIPE
27 503044 CLIP
28 503021-332C RIGHT FRAME
29 503022-332 OBSERVATION COVER
30 503023 AXLE
31 511019 BATTERY
32 599606 BATTERY TIE
33 503048 DC VOLTAGE REGULATOR
34 503024 KNOB
35 500068 HANDLE BAFFLE PLUG
36 500060 LOCKER M6
37 503025 PLUG
38 503026 ISOLATION PAD
39 503027 MUFFLER COVER
40 503028 FUEL TANK CAP
41 503029 FUEL SLOT
42 503067 BLIND RIVET
43 503031 WHEEL
44 503032 WHEEL COVER
45 500108 MUFFLER EXHAUST SEALING STRIP
46 503033 PULL ROD HOLDER
NO. PART # DESCRIPTION
--- --- ---
47 503034 FUEL HOSE CLIP
48 503035 PULL ROD
49 503036-052 HANDLE DECORATIVE BOARD
50 500017-231 HANDLE COVER
51 91825 CROSS RECESSED PAN HEAD SCREW

& FLAT WASHER M5X12

52| 503038-332| TOP CAP
53| 503039-332C| LEFT PANEL
54| 503040| COVER
55| 91335| BOLT M6X35
56| 95127| CARBON CANISTER AND FUEL TANK CONNECTING PIPE
57| 503045| BOTTOM PLATE
58| 518801| FILTER
59| 516401| FILTER
60| 94405| FUEL HOSE CLIP 11.5
61| 500018| HANDLE
62| 500044| SHORT CIRCUITING WIRE
63| 503047| CONTROL MODULE
64| 91348| BOLT M8X35
65| 94022| STEEL WASHER
66| 94249| FLAT WASHER
67| 92097| HEXAGON SCREW WITH FLANGE M6X20
68| 503165| BATTERY WIRE
69| 503388| DEPUTY WIRING HARNESS
70| 94003| TOOTH WASHER
71| 503061| CONTROL PANEL ASSEMBLY
71.1| 9022| ONE PUSH START BUTTON
71.2| 9032| ECO SWITCH
71.3| 9079| WATERPROOF CAP
71.4| 9025| CHARGING INDICATOR
71.5| 9089| STARTING INDICATOR
71.6| 97537| IGNITER
71.7| 9141| USB
71.8| 503108| USB DUST COVER
71.9| 9021| RESET BUTTON
71.10| 9110| LED
71.11| 9136| PARALLEL PORTS
71.12| 9122| WATERPROOF COVER
71.13| 9132| GROUNDING BOLT
72| 94403| FUEL PIPE CLIP ?7.5
73| 92032| SCREW M4*16
74| 90010| NUT M6
75| 91330| BOLT M6X20
76| 91397| BOLT M6X20
77| 96801| FUEL TANK WASHER

GENERATOR PART NUMBERS (CONTINUED

NO. PART # DESCRIPTION
78 92078 CROSS RECESSED PAN HEAD BOLT

M6X16

79| 500007| FUEL TANK ISOLATION PAD A
80| 92079| RETAINING BOLT M6X16
81| 503052| BASE OIL COVER
82| 503053| RESTRICTOR BLOCK
83| 500321| AXLE OUTER CLIP
84| 91334| BOLT M6X30
85| 8.55464E+11| ENGINE ASSEMBLY DH225
86| 500244| PRESS PLATE
87| 500324| SEALING WASHER
88| 500247| GASOLINE SENSOR
89| 500252| SEALING RING
90| 94218| FLAT WASHER
91| 543301L| CARBON CANISTER ASSEMBLY
92| 503043| BRACKET
93| 95016| CARBON CANISTER AND AIR FILTER CONNECTING PIPE
94| 94409| FUEL PIPE CLIP
95| 503082| CORRUGATED PIPE
96| 503310| KNOB PLUG
97| 599601| METAL CLIP
98| 99011| SPARK PLUG WRENCH
99| 500942| FUNNEL
100| 99547| OIL BOTTLE
101| 511043| CHARGER
102| 99506| SCREWDRIVER

Westinghouse iGen4500DF Digital Inverter Generator-43

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Westinghouse User Manuals

Related Manuals