EDiMAX EW-7489WAX Wireless Router Installation Guide

June 13, 2024
EDIMAX

edimax-logo-png-transparent

EDiMAX EW-7489WAX Wireless Router

EDiMAX-EW-7489WAX-Wireless-Router-PRODUCT

Product Information

The product in question is a wireless access point with two models: EW-7489WAX and EW-7689WTX. It comes with a Quick Installation Guide and Product Specification for easy setup and reference.

Product Specifications:

  • Wireless Technology: Supports wireless connectivity
  • External Interface: IO port locations
  • Internal Interface: LED definition (For Alpha/Beta/Charlie/Delta)
  • PCB Dimension: Not specified
  • Enclosure Dimension: Not specified
  • Power supply: POE 802.3at PD DC 12V1.5A (for EW-7489WAX only)
  • Operating Temperature: 0 ~ 40 degree C
  • Kensington lock: Supports Kensington lock for physical security

LED Indications:

LED Color LED Status Description
Solid Green Normal Operation AP is on and connected to the wireless

controller
Flashing Green| AP is booting & connecting to wireless controller| AP is in the process of starting up and establishing a
connection
Solid Red| Error, no wireless controller found| AP cannot find a wireless controller and will reboot if not
claimed
Flashing Slow Red| AP preparing configuration reset| AP is resetting its configuration settings
Flashing Fast Red| Firmware update in progress| AP is currently updating its firmware, do not disconnect from
power
Solid Amber| AP has no connection to the wireless controller| AP is not connected to a wireless controller
Flashing Amber| AP is not claimed by wireless controller| AP is not yet claimed by a wireless controller
LED Off| AP is off or reboot started| AP is turned off or in the process of rebooting

Product Usage Instructions

Safety Instructions:

  • Do not reach into the appliance as there are dangerous circuits inside that can cause harm.
  • If the appliance is damaged, return it and avoid opening or changing its components to maintain warranty cover.
  • Connect the device to a power socket with a fully functional earth conductor to ensure safety and electromagnetic compatibility.
  • The socket-outlet should be installed near the equipment and easily accessible.
  • Before switching on the appliance, verify that the mains voltage matches the supply voltage mentioned on the name plate.
  • To disconnect the appliance completely, remove the power cable from the power socket and ensure the power plug remains freely accessible.
  • Avoid tripping over or damaging the power cable to prevent accidents.
  • Only connect system peripherals that comply with the requirements for protective extra-low voltage.
  • Use only parts and accessories validated by EDIMAX to maintain proper functioning and safety.
  • Ensure sufficient air circulation to remove heat produced by the appliance.
  • Avoid high levels of air humidity, condensation, water damage, or smoke coming out of the appliance as it may affect its safe operation.
  • In case of any problems mentioned above, immediately turn off the appliance, disconnect the power cable, and contact customer service.
  • Product liability and warranty claims are excluded if the appliance is not operated according to the provided instructions.

Product Specification



Wireless Technology

| •       IEEE 802.11b/g/n/ax 2.4GHz 1024QAM with 574Mbpps

•       IEEE 802.11a/n/ac/ax 5GHz 1024QAM with    2400Mbps

•       SupportMU‐MIMO/OFDMA at 2.4GHz and 5GHz

---|---




External Interface

| •       1x GE LAN(PoE 802.3at PD)

•       1 x Console port

•       1x 12V DC Jack

•       1 x reset button

•       1x WPS

•       1x console port RJ45

Internal Interface| •       1 x Console Port PIN connector (for core‐board UART use)
LED| •       1xtri‐color LED


PCB Dimension

| •       Core board: 75x84mm/6L

•       Main board: 170x150mm/4L



Enclosure Dimension

| •       183.3×183.3x 32mm (follow Acelink EW‐7679WIC housing housing)

•       Material:Plenum Graded

•       Open new lower housing tooling to accomendate brackets and Kensington lock


Power supply

| POE 802.3at PD

DC 12V1.5A (for EW‐7489WAX only)

Operating Temperature| 0 ~ 40 degree C

IO port locations

EDiMAX-EW-7489WAX-Wireless-Router-FIG- \(1\)

LED definition

Description (For Alpha/Beta/Charlie/Delta) LED
AP is off or reboot started Off
Normal Operation Solid Green
AP is booting & connecting to wireless controller Flashing Green

Error, no wireless controller found. AP will reboot (if not yet claimed by a controller). Check network connection if error persists.

If reset button pressed: AP preparing configuration rese

| ****

Solid Red

Configuration reset in progress | Flashing Slow Red
Firmware update in progress

Note: Do not disconnect from power

| Flashing Fast Red
AP has no connection to the wireless controller| Solid Amber
AP is not claimed by wireless controller| Flashing Amber

Safety Instructions

  • You can operate the access point (AP) safely if you follow the information in these Safety Instructions and on the appliance.
  • Do not reach into the appliance. There are dangerous circuits inside the appliance that can cause death if you touch them.
  • Damaged appliances must be returned. It is forbidden to open the hardware appliance or to change its components. Failure to comply with this rule results in the loss of warranty cover from EDIMAX.
  • Connect the device to a power socket with a fully functional earth conductor. Defective earth conductor connections do not comply with the requirements for safety and electromagnetic compatibility. Check the power socket before connecting the hardware appliance.
  • The socket-outlet shall be installed near the equipment and shall be easily accessible.
  • Before you switch on the appliance make sure that your mains voltage complies with the supply voltage of the appliance. The connection data are shown on the name plate.
  • To disconnect the appliance completely take the power cable from the power socket. Make sure that the power plug is freely accessible.
  • Make sure that no one can trip over the power cable and that it cannot be damaged by objects.
  • Only connect system peripherals complying with the requirements for protective extra-low voltage according to EN/IEC 62368-1.
  • Only use parts and accessories validated by EDIMAX. Using non-approved parts and accessories may affect the functioning of the appliance and your safety.
  • The appliance produces heat. Ensure that there is sufficient air circulation to remove the heat.
  • Avoid a permanent high level of air humidity and formation of condensation. Protect the appliance from humidity and chemicals. Safe use of the appliance is no longer possible if: the chassis is damaged water penetrated the appliance objects entered the appliance via air opening smoke comes out of the appliance the power cable is damaged it does not work properly
  • Immediately turn off the appliance in the event of one of the above problems, remove the power cable from the power socket and contact your customer service as soon as possible.
  • We expressly exclude any product liability and warranty claims if the appliance is not operated according to the instructions in these notes and to the notes attached to the appliance itself.

PoE-Injector Safety Information

Caution : The PoE injector is to be connected only to PoE networks without routing to the outside plant.

Power Cord:

  • The power cord must have regulatory agency approval for the specific country in which it is used (for example, UL, CSA, VDE, GS, etc.).
  • The power cord must be a three-conductor type (two current carrying conductors; one ground conductor terminated on one end by an IEC 60320 appliance coupler (for connection to the PoE- Injector), and on the other end by a plug containing a ground (earthing) contact).
  • The power cord must be razed for a minimum of 250 VAC RMS operation, with a minimum rated current capacity of 5 A (or a minimum wire gauge of 18 AWG (0.75 mm2)).
  • A PoE-Injector installed in Australia requires power cords with a minimum wire gauge of 16 AWG (1.0 mm2).
  • The PoE-Injector “Data In” and “Data & Power Out” ports are shielded RJ45 data sockets. They cannot be used as Plain Old Telephone Service (POTS) telephone sockets. Connect RJ45 data connectors only to those sockets.
  • The AC wall socket-outlet must be near the PoE-Injector and easily accessible. You can remove AC power from the PoE-Injector by disconnecting the AC power cord from either the wall socket-outlet or the PoE-Injector appliance coupler.
  • The PoE-Injector “Data In” and “Data & Power Out” interfaces are qualified as Safety Extra-Low Voltage (SELV) circuits according to IEC 62368-1. Connect these interfaces only to SELV interfaces on other equipment.

Warnings: Connect the PoE-Injector only to the IP device with which it was bought. Using the PoE-Injector with other IP devices can cause damage to the IP device.

  • Read the installation instructions before connecting the PoE-Injector to its power source.
  • Follow basic electricity safety measures whenever connecting the PoE-Injector to its power source.
  • A voltage mismatch can cause equipment damage and may pose a fire hazard. If the voltage indicated on the label is different from the power outlet voltage, do not connect the PoE-Injector to that power outlet.

Federal Communication Commission Interference Statement

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. this device must accept any interference received, including interference that may cause undesired operation.

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one of the following measures:

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

FCC Caution : Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

Radiation Exposure Statement:

This equipment complies  with  FCC  radiation  exposure  limits  set  forth for  an uncontrolled environment. This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

Note : The country code selection is for non-US model only and is not available to all US model. Per FCC regulation, all WiFi product marketed in US must fixed to US operation channels only.

FCC regulations restrict the operation of this device to indoor use only.

Industry Canada statement

This device contains licence-exempt transmitter(s)/receiver(s) that comply with Innovation, Science and Economic Development Canada’s licence-exempt RSS(s). Operation is subject to the following two conditions:

  1. This device may not cause interference.
  2. This device must accept any interference, including interference that may cause undesired operation of the devie.

Caution: Operation shall be limited to indoor use only; Utilisation limitée à l’intérieur seulement;

Radiation Exposure Statement

This equipment complies with ISED radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with greater than 23cm between the radiator & your body.

RED Compliance Statement

Compliance with 2014/53/EU Radio Equipment Directive (RED)
In accordance with Article 10.8(a) and 10.8(b) of the RED, the following table provides information on the frequency bands used and the maximum RF transmit power of the product for sale in the EU:

Frequency Range (MHz) Max. Transmit Power (dBm) EIRP
2412 ~ 2472 19.91 dBm
5180 ~ 5240 22.98 dBm
5250 ~ 5320 22.93 dBm
5500 ~ 5700 22.92 dBm

This equipment should be installed and operated with minimum distance 20cm between the radiator & your body.

| AT| BE| BG| HR| CY| CZ| DK
---|---|---|---|---|---|---|---
EE| FI| FR| DE| EL| HU| IE
IT| LV| LT| LU| MT| NL| PL
PT| RO| SK| SI| ES| SE| UK(NI)

This device is restricted to indoor use

Declaration of Conformity

We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the European Radio Equipment directives.

  • Equipment: Access Point
  • Model No.: EW-7489WAX, EW-7689WTX

**** The following European standards for essential requirements have been followed:

Directives 2014/53/EU

  • Spectrum : EN 300 328 V2.2.2 (2019-07) EN 301 893 V2.1.1 (2017-05)
  • EMC : EN 301 489-1 V2.2.3 (2019-11)EN 301 489-17 V3.2.4 (2020-09)
  • EMF :  EN 55032:2015+A11:2020 Class B EN 55035:2017+A11:2020
  • Safety ( LVD ) : IEC 62368-1:2014 (2nd Edition) and/or EN 62368-1:2014+A11:2017

Edimax Technology Europe B.V. Fijenhof 2, 5652 AE Eindhoven, The Netherlands

Date & Place of Issue: 31/May/2022, Eindhoven Signature:

  • Printed Name : David Huang
  • Title : Director

A Company of: Edimax Technology Co., Ltd. No. 278, Xinhu 1st Rd., Neihu Dist., Taipei City, Taiwan

Date & Place of Issue: 31/May/2022, Taipei

Signature :

  • Printed Name : Hunter Chen
  • Title : Director

Declaration of Conformity
We, Edimax Technology Co., Ltd., declare under our sole responsibility, that the equipment described below complies with the requirements of the United Kingdom Radio Equipment directives.

  • Equipment: Access Point
  • Model No.: EW-7489WAX, EW-7689WTX

The following European standards for essential requirements have been followed:

Radio Equipment Regulations 2017 (S.I. 2017/1206)

  • Spectrum : EN 300 328 V2.2.2 (2019-07) EN 301 893 V2.1.1 (2017-05)
  • EMC : EN 301 489-1 V2.2.3 (2019-11)EN 301 489-17 V3.2.4 (2020-09)
  • EMF : EN 55032:2015+A11:2020 Class B EN 55035:2017+A11:2020
  • Safety ( LVD ): IEC 62368-1:2014 (2nd Edition) and/or EN 62368-1:2014+A11:2017

Edimax Technology Europe B.V. Fijenhof 2, 5652 AE Eindhoven, The Netherlands

Date & Place of Issue: 31/May/2022, Eindhoven

Signature :

  • Printed Name : David Huang
  • Title : Director

A Company of: Edimax Technology Co., Ltd. No. 278, Xinhu 1st Rd., Neihu Dist., Taipei City, Taiwan

Date & Place of Issue: 31/May/2022, Taipei

Signature:

  • Printed Name : Hunter Chen
  • Title : Director

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

EDIMAX User Manuals

Related Manuals