COOPER Lighting Solutions IL514001EN 1002 LED Accent and Flood Light Instruction Manual
- June 3, 2024
- COOPER Lighting Solutions
Table of Contents
COOPER Lighting Solutions IL514001EN 1002 LED Accent and Flood Light
Lumiere Instructions
WARNING
Make Certain Power is OFF before starting installation or attempting any
maintenance.
WARNING
Risk of Fire/Electric Shock. If not qualified, consult an electrician.
WARNING
Risk of Electric Shock – Disconnect power at fuse or circuit breaker before
installing or servicing.
WARNING
Risk of Personal Injury – Fixture may become damaged and/or unstable if not
installed properly.
- Do not mount luminaire within 6” of a combustible surface.
- Do not handle luminaire by the glass. Do not touch LEDs.
WARNING
Risk of Burn – Disconnect power and allow fixture to cool before servicing.
Note:
- These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation, operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
- This lighting fixture has been shipped complete with one of several mounting options. Please follow the installation instructions specific to the catalog part that you ordered.
- Care must be taken not to set lighting fixture down on optical lenses or lift the fixture in the lens area.
- Specifications and dimensions subject to change without notice.
IMPORTANT : Read carefully before installing fixture. Retain for future reference.
GENERAL : Upon receipt of the fixture, thoroughly inspect for any freight damage which should be brought to the attention of the delivery carrier. Compare the catalog description listed on the packing slip with the fixture label on the housing to assure you have received the correct material.
SAFETY : This fixture must be wired in accordance with the National Electrical Code and applicable local codes and ordinances. Proper grounding is required to insure personal safety. Carefully observe grounding procedure under installation section.
APPLICATIONS : This lighting fixture is designed for outdoor lighting services, and should not be used in area of limited ventilation or inside high ambient temperature enclosures. It must be stored in a dry location prior to installation. Do not expose lighting fixture to rain, dust or other environmental conditions prior to installation and insertion of photo control or shorting cap (if so equipped). Do not install the fixture near combustible materials or locate next to airflow blocking surfaces within 6 inches. Best results will be obtained if installed and maintained according to the following recommendations.
WIRING TABLE
Note : *Constructions built before Jan 2022 may have gray wire for 0-10 dimming control present. In these cases, the installer will label the gray building wire as a 0-10 dimming wire and connect to our product’s pink 0-10V dimming control wire. Reference NFPA70 (2020 NEC), section 410.69.
INSTALLATION
ACCENTS
-
Unpack and ensure all included parts are present.
-
Unscrew 4x mounting hardware from driver mounting plate, separate the Luminaire Disconnect to separate driver mounting plate from fixture assembly.
-
Connect building AC supply wires from junction box to input wire side of LED driver with push nuts (included). Ensure excess ground wire can extend out of junction box.
Note:
Junction boxes must be min size of 2-1/8” deep and 4” square. Recommended Junction boxes are Crouse-Hinds part numbers TP403, TP432, TP434, TP438, TP395, or equivalent. -
Separate and route Luminaire Disconnect and ground wire out of center hole in driver mounting plate, Attach driver mounting plate to existing junction box with proper hardware (not included).
-
Re-connect ground wire and Luminaire Disconnect to fixture assembly.
-
Attach mount plate and gasket to driver mounting plate with 4x mounting hardware. Ensure adequate gasket compression to provide proper seal from the environment.
-
Using a 3/32” Allen Wrench, slightly loosen the set screw at knuckle base for rotational adjustment. Using a 9/64” Allen Wrench, slightly loosen the screw at the knuckle joint for angle adjustment. Once properly positioned, ensure both screws are secured.
CYLINDERS
-
Unpack and ensure all included parts are present.
-
Unscrew 2x mounting hardware from driver mounting plate, separate the Luminaire Disconnect to separate driver mounting plate from fixture assembly.
-
Connect building AC supply wires from junction box to input wire side of LED driver with push nuts (included). Connect ground wire to junction box. Ensure excess ground wire can extend out of junction box.
Note:
Junction boxes must be min size of 2-1/8” deep and 4” square. Recommended Junction boxes are Crouse-Hinds part numbers TP403, TP432, TP434, TP438, TP395, or equivalent. -
Separate and route Luminaire Disconnect and ground wire out of center hole in driver mounting plate. Attach driver mounting plate to existing junction box with proper hardware (not included).
-
Re-connect ground wire and Luminaire Disconnect to fixture assembly.
-
Attach mount plate and gasket to driver mounting plate with 2x mounting hardware. Ensure adequate gasket compression to provide proper seal from the environment.
SIGNS
-
Unpack and ensure all included parts are present.
-
Unscrew 4x mounting hardware from driver mounting plate, separate the Luminaire Disconnect to separate driver mounting plate from fixture assembly.
-
Connect building AC supply wires from junction box to input wire side of LED driver with push nuts (included). Connect ground wire to junction box. Ensure excess ground wire can extend out of junction box.
Note:
Junction boxes must be min size of 2-1/8” deep and 4” square. Recommended Junction boxes are Crouse-Hinds part numbers TP403, TP432, TP434, TP438, TP395, or equivalent. -
Separate and route Luminaire Disconnect and ground wire out of center hole in driver mounting plate, Attach driver mounting plate to existing junction box with proper hardware (not included).
-
Re-connect ground wire and Luminaire Disconnect to fixture assembly. Attach mount plate and gasket to driver mounting plate with 4x mounting hardware. Ensure adequate gasket compression to provide proper seal from the environment.
-
Using a 3/32” Allen Wrench, slightly loosen the set screw at knuckle base for rotational adjustment. Using a 9/64” Allen Wrench, slightly loosen the screw at the knuckle joint for angle adjustment. Once properly positioned, ensure both screws are secured.
Warranties and Limitation of Liability
Please refer to www.cooperlighting.com for our terms and conditions.
Cooper Lighting Solutions 1121 Highway 74 South Peachtree City, GA 30269 P:
770-486-4800
www.cooperlighting.com
© 2022 Cooper Lighting Solutions All Rights Reserved Printed in USA Imprimé
aux États-Unis Impreso en los EE. UU. Publication No. IL514001EN March 14,
2022
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>