SKYDANCE PT-40A-2 RF Constant Current LED CCT Driver User Manual

June 5, 2024
SKYDANCE

SKYDANCE PT logo PT-40A-2 RF Constant Current LED CCT Driver
User Manual

SKYDANCE PT 40A 2 RF Constant Current LED CCT Driver
User

RF Constant Current LED CCT Driver
Model No.: PT-40A-2
User Manual Ver 1.0.1  

fig 1

Features

  • Dimming interface: RF Wireless, AC Push-Dim
  • Match with RF 2.4G single color remote control, one RF LED driver accepts up to 10 remote controls
  • Universal AC input / Full range
  • Flicker-free
  • 2 channel constant current output, con
  • Built-in active PFC function: 0.98 Typ
  • Auto-transmitting function: LED driver automatically transmits a signal to another LED driver with a 30m control distance
  • Synchronize on multiple LED drivers
  • Fade in and out effect selectable
  • 3 levels of color temperature (WW, NW, and CW) selectable by continuous power off and on during the operation
  • Over-heat / Over-load / Short circuit protection, recover automatically
  • Full protective plastic case
  • Suitable for indoor LED lighting application
  • 5 Year, 50,000hr warranty

Mechanical Structures and Installations

SKYDANCE PT 40A 2 RF Constant Current LED CCT Driver User - Mechanical
Structures

Technical Parameters

Output Output Voltage 10∼52VDC
Output Current 2x (450∼1200) mA
Output Power Max. 40W
Max Output Voltage 60VCC
Dimming Range 0∼100%
PWM frequency 800011z
Current Accuracy ±5%
Ripple&Noise -c 150mV
Input Input Voltage Range 100∼240VAC
Frequency Range 50/60Hz
Efficiency >85%
Alternating Current 0.43A Max.
Anti Surge L-N: I .2KV
Startup time 15/230VAC
Power Factor >0.99/110VAC, >098/230VAC
THD <6%
Inrush Current Cold start 18.8A at 230VAC
Leakage Current < 0.5mA/2301/AC
No Load Power < 16W
Protection Over Load Power When 0/P voltage exceeds its range, 0/P current

declines, and auto recovers when the bad is reduced.
Short Circuit| Shut down automatically if a short circuit occurs, and auto recovers.
Over Temperature| Intelligently adjust or turn all the output current if the PCB temp > 100t, auto recovers
Environment| Waking Temperature| -30t∼50t
Tcase Max| 86º C
Working Humidity| 20% ∼90%RH, non-condensing
Storage Temp/Humidity| .40°C∼80t. 10%-95%RH
Temperature Coefficient| ±0.03%/t A50%1
Vibration Resistance| 10-500Hz, 2G, 6min/cycle, X.Y,Z axes/2min
IP Rating| IP20
Sofety&EMC| Security Specifications| IEC/EN61347-1, IEC/EN613472-13
Withstand Voltage| I/P-0/P: 3750VAC
Insulation Resistance| I/P-0/P: IODM0/5COVDC/25.C/70%RH
EMC Emission| EN55015. EN61000-3-2 Class C,1E051CCX3-3-3
EMC Immunity| EN610004-2.3.4.5.6.8. II, EN6 1547
Certifications| CE. EMC

LED Current Selection:

SKYDANCE PT 40A 2 RF Constant Current LED CCT Driver User - LED
Current

Applications

  • Suitable for downlight, spotlight, and decorative applications.
  • Warehouse, Health care, Retail, and Display.
  • Use for retro

Wiring Diagram

1. RF Connection

SKYDANCE SKYDANCE PT 40A 2 RF Constant Current LED CCT Driver User -
DiagramPT 40A 2 RF Constant Current LED CCT Driver User -
Diagram

Note: Continuously switch off and on the power supply two times rapidly, It will change 3 levels of color temperature (WW, NW, and CW) in sequence.
Match Remote Control (two-match ways)
End-user can choose the suitable match/delete ways. Two options are offered for selection:

Use Match key Use Power Restart

Match:
Short press the match key, and immediately press the on/off key (single- zone emote) or zone key (multiple zones remote) of the remote.
Delete:
Press and old match key for 5s to delete all matches, The light blinks 5 times means all matched remotes were deleted.| Match:
Switch off the power, then switch on the power, and repeat again. Immediately hort press the on/off key (single-zone remote) or zone key (multiple zones remote) 3 times on the remote. The light blinks 3 times means the match is successful.
Delete:
Switch off the power, then switch on the power, and repeat again. Immediately short dress on/off key (single-zone remote) or zone key (multiple zones remote) 5 times n the remote. The light blinks 5 times means all matched remotes were deleted.

When using multiple RF drivers, two application methods:

  1. All the drivers are in the same zone.
    Auto-transmitting: One driver can transmit the signals from the remote to another driver within 30m,
    as long as there is a driver within 30m, the remote control distance can be extended.
    A uto-synchronization: Multiple drivers within a 30m distance can work synchronously when they are controlled by the same remote. Driver placement may offer up to  0m communication distance. Metals and other metal materials will reduce the range. Strong signal sources such as WiFi routers and microwave ovens will affect the range. We recommend for indoor applications that driver placements should be no further apart than15m.

  2. Each driver(one or more) is in a different zone, like zone 1, 2, 3, or 4.

2. AC Push-Dim connection
SKYDANCE PT 40A 2 RF Constant Current LED CCT Driver User - . AC Push-
Dim
The provided AC Push-Dim interface allows for a simple dimming method using commercially available non-latching (momentary) wall switches.

  • Short press: Turn on or off the light.
  • Long press (1-6s): Press and hold to step-less dimming, With every other long press, the light level goes in the opposite direction.
  • Dimming memory: Light returns to the previous dimming level when switched off and on again, even at power failure.
  • Synchronization: If more than one LED driver is connected to the same push switch, do a long press for more than 10s, then the system is synchronized and all lights in the roup dim up to 100%. This means there is no need for any additional synchrony wire in larger installations. We recommend the number of LED drivers connected to a push witch does not exceed 25 pieces, The maximum length of the wires from the push to the LED driver should be no more than 50 meters.

Dimming Curve

Fade in and Fade out Setting
Long press match key 5s, then short press match key 3 times, The lighting effect will be set to the fade in and fade out in 3s, and the indicator light of the LED controller blinks 3 times.
Long press match key 10s, restore factory default parameter, and the light on/off time restores to 0.5s.

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals