SKYDANCE PT-40A-2 RF Constant Current LED CCT Driver User Manual
- June 5, 2024
- SKYDANCE
Table of Contents
PT-40A-2 RF Constant Current LED CCT Driver
User Manual
RF Constant Current LED CCT Driver
Model No.: PT-40A-2
User Manual Ver 1.0.1
Features
- Dimming interface: RF Wireless, AC Push-Dim
- Match with RF 2.4G single color remote control, one RF LED driver accepts up to 10 remote controls
- Universal AC input / Full range
- Flicker-free
- 2 channel constant current output, con
- Built-in active PFC function: 0.98 Typ
- Auto-transmitting function: LED driver automatically transmits a signal to another LED driver with a 30m control distance
- Synchronize on multiple LED drivers
- Fade in and out effect selectable
- 3 levels of color temperature (WW, NW, and CW) selectable by continuous power off and on during the operation
- Over-heat / Over-load / Short circuit protection, recover automatically
- Full protective plastic case
- Suitable for indoor LED lighting application
- 5 Year, 50,000hr warranty
Mechanical Structures and Installations
Technical Parameters
Output | Output Voltage | 10∼52VDC |
---|---|---|
Output Current | 2x (450∼1200) mA | |
Output Power | Max. 40W | |
Max Output Voltage | 60VCC | |
Dimming Range | 0∼100% | |
PWM frequency | 800011z | |
Current Accuracy | ±5% | |
Ripple&Noise | -c 150mV | |
Input | Input Voltage Range | 100∼240VAC |
Frequency Range | 50/60Hz | |
Efficiency | >85% | |
Alternating Current | 0.43A Max. | |
Anti Surge | L-N: I .2KV | |
Startup time | 15/230VAC | |
Power Factor | >0.99/110VAC, >098/230VAC | |
THD | <6% | |
Inrush Current | Cold start 18.8A at 230VAC | |
Leakage Current | < 0.5mA/2301/AC | |
No Load Power | < 16W | |
Protection | Over Load Power | When 0/P voltage exceeds its range, 0/P current |
declines, and auto recovers when the bad is reduced.
Short Circuit| Shut down automatically if a short circuit occurs, and auto
recovers.
Over Temperature| Intelligently adjust or turn all the output current if the
PCB temp > 100t, auto recovers
Environment| Waking Temperature| -30t∼50t
Tcase Max| 86º C
Working Humidity| 20% ∼90%RH, non-condensing
Storage Temp/Humidity| .40°C∼80t. 10%-95%RH
Temperature Coefficient| ±0.03%/t A50%1
Vibration Resistance| 10-500Hz, 2G, 6min/cycle, X.Y,Z axes/2min
IP Rating| IP20
Sofety&EMC| Security Specifications| IEC/EN61347-1, IEC/EN613472-13
Withstand Voltage| I/P-0/P: 3750VAC
Insulation Resistance| I/P-0/P: IODM0/5COVDC/25.C/70%RH
EMC Emission| EN55015. EN61000-3-2 Class C,1E051CCX3-3-3
EMC Immunity| EN610004-2.3.4.5.6.8. II, EN6 1547
Certifications| CE. EMC
LED Current Selection:
Applications
- Suitable for downlight, spotlight, and decorative applications.
- Warehouse, Health care, Retail, and Display.
- Use for retro
Wiring Diagram
1. RF Connection
Note: Continuously switch off and on the power supply two times rapidly,
It will change 3 levels of color temperature (WW, NW, and CW) in sequence.
Match Remote Control (two-match ways)
End-user can choose the suitable match/delete ways. Two options are offered
for selection:
Use Match key | Use Power Restart |
---|
Match:
Short press the match key, and immediately press the on/off key (single-
zone emote) or zone key (multiple zones remote) of the remote.
Delete:
Press and old match key for 5s to delete all matches, The light blinks 5 times
means all matched remotes were deleted.| Match:
Switch off the power, then switch on the power, and repeat again.
Immediately hort press the on/off key (single-zone remote) or zone key
(multiple zones remote) 3 times on the remote. The light blinks 3 times means
the match is successful.
Delete:
Switch off the power, then switch on the power, and repeat again. Immediately
short dress on/off key (single-zone remote) or zone key (multiple zones
remote) 5 times n the remote. The light blinks 5 times means all matched
remotes were deleted.
When using multiple RF drivers, two application methods:
-
All the drivers are in the same zone.
Auto-transmitting: One driver can transmit the signals from the remote to another driver within 30m,
as long as there is a driver within 30m, the remote control distance can be extended.
A uto-synchronization: Multiple drivers within a 30m distance can work synchronously when they are controlled by the same remote. Driver placement may offer up to 0m communication distance. Metals and other metal materials will reduce the range. Strong signal sources such as WiFi routers and microwave ovens will affect the range. We recommend for indoor applications that driver placements should be no further apart than15m. -
Each driver(one or more) is in a different zone, like zone 1, 2, 3, or 4.
2. AC Push-Dim connection
The provided AC
Push-Dim interface allows for a simple dimming method using commercially
available non-latching (momentary) wall switches.
- Short press: Turn on or off the light.
- Long press (1-6s): Press and hold to step-less dimming, With every other long press, the light level goes in the opposite direction.
- Dimming memory: Light returns to the previous dimming level when switched off and on again, even at power failure.
- Synchronization: If more than one LED driver is connected to the same push switch, do a long press for more than 10s, then the system is synchronized and all lights in the roup dim up to 100%. This means there is no need for any additional synchrony wire in larger installations. We recommend the number of LED drivers connected to a push witch does not exceed 25 pieces, The maximum length of the wires from the push to the LED driver should be no more than 50 meters.
Dimming Curve
Fade in and Fade out Setting
Long press match key 5s, then short press match key 3 times, The lighting
effect will be set to the fade in and fade out in 3s, and the indicator light
of the LED controller blinks 3 times.
Long press match key 10s, restore factory default parameter, and the light
on/off time restores to 0.5s.
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>