turbofan P8M P Series Prover Holding Cabinets User Manual

June 1, 2024
turbofan

P8M P Series Prover Holding Cabinets

“`html

Specifications

  • P8M Proofer / Holding Cabinet

  • Power Ratings: 110-120V, 1P+N+E, 60HZ, 1.45 kW

  • Tray Capacity: 8, 18 x 26 / 460 x 660 Full Size Sheet Pan
    Capacity; 16, 18 x 13 / 460 x 330 Half Size Sheet Pan Capacity; 8,
    600 x 400mm Tray Capacity (Optional Kit)

  • Tray Spacing: 76mm / 3″

  • P10M Proofer / Holding Cabinet

  • Power Ratings: 110-120V, 1P+N+E, 60HZ, 1.45 kW

  • Tray Capacity: 10, 1/1 GN Gastronorm Pan Capacity; 10, 20 x 12
    Hotel Steam Pan Capacity; 10, 18 x 13 Half Size Sheet Pan
    Capacity

  • Tray Spacing: 74mm / 2 7/8″

  • P12M Proofer / Holding Cabinet

  • Power Ratings: 110-120V, 1P+N+E, 60HZ, 1.95 kW

  • Tray Capacity: 12, 18 x 26 / 460 x 660 Full Size Sheet Pan
    Capacity; 24, 18 x 13 / 460 x 330 Half Size Sheet Pan Capacity; 12,
    600 x 400mm Tray Capacity (Optional Kit)

  • Tray Spacing: 76mm / 3″

Installation

Installation Requirements

Important: Installation shall comply with local
electrical, health and safety requirements. It is crucial that the
proofer/holding cabinet is correctly installed and operated before
use.

If you have any questions regarding the proper installation and
operation of this proofer/holding cabinet, please refer to the user
manual for detailed instructions.

Operation

Proofer/Holding Cabinet Control Panel

The control panel of the proofer/holding cabinet allows you to
set and monitor the temperature and humidity levels to ensure
proper proofing or holding of food items.

Usage Instructions

  1. Ensure the proofer/holding cabinet is correctly installed and
    connected to the power source.

  2. Open the control panel and set the desired temperature and
    humidity levels based on your food product requirements.

  3. Place the food items on the appropriate trays inside the
    cabinet, ensuring proper spacing for even proofing or holding.

  4. Close the cabinet door securely to maintain the internal
    temperature and humidity levels.

  5. Monitor the food items periodically to ensure they are proofed
    or held at the desired conditions.

FAQ

Q: Can I adjust the temperature settings on the proofer/holding

cabinet?

A: Yes, you can adjust the temperature settings using the
control panel to suit your specific food proofing or holding
requirements.

Q: How often should I clean the proofer/holding cabinet?

A: It is recommended to clean the cabinet regularly based on
usage and follow the cleaning instructions provided in the user
manual to maintain hygiene and performance.

“`

PSERIES
P8M/P10M/P12M Series
Proofer/Holding Cabinets (Manual Operation)
Service Manual

26 July 2013

Amendment 2

Contents List
P8M/P10M/P12M Turbofan Proofer/Holding Cabinets.
Model Numbers Covered in this Manual
P8M – Turbofan Proofer / Holding Cabinet – 8 Tray. P10M – Turbofan Proofer / Holding Cabinet – 10 Tray. P12M – Turbofan Proofer / Holding Cabinet – 12 Tray.
1. Specifications …………………………………………………………………………………….2
2. Installation………………………………………………………………………………………..5 Installation Requirements Unpacking Location Clearances Electrical Connection Water Connection Positioning of Proofer / Holding Cabinet
3. Operation ………………………………………………………………………………………….7 Proofer / Holding Cabinet Control Panel
4. Fault Finding ……………………………………………………………………………………..8 Operational Faults Component Testing Element Resistance and Current Value Table
5. Service Procedures……………………………………………………………………………10 5.1 Access 5.2 Replacement 5.3 Adjustment and Calibration
6. Electrical Schematic ………………………………………………………………………….16
7. Wiring Diagram ………………………………………………………………………………..17
8. Replacement Parts List ……………………………………………………………………..18
Appendix 1 – Proofer Door Reversal (P8 – P12 Proofer/Holding Cabinets only) A1
Warning
ALL INSTALLATION AND SERVICE REPAIR WORK MUST BE CARRIED OUT BY QUALIFIED PERSONS ONLY. IMPROPER INSTALLATION, ALTERATION, ADJUSTMENT, MAINTENANCE OR SERVICE MAY CAUSE PROPERTY DAMAGE, INJURY OR DEATH. ENSURE SUPPLY IS SWITCHED OFF BEFORE SERVICING. ALWAYS TEST AFTER SERVICE REPAIRS.

Specifications
P8M Proofer / Holding Cabinet

P8M Specifications Table:-

Power Ratings Tray Capacity

110-120V, 1P+N+E, 60HZ, 1.45 kW
8, 18″ x 26″ / 460 x 660, Full Size Sheet Pan Capacity. 16, 18″ x 13″ / 460 x 330, Half Size Sheet Pan Capacity. 8, 600 x 400mm Tray Capacity (Optional Kit).

Tray Spacing

76mm / 3″

2

Specifications
P10M Proofer / Holding Cabinet

P10M Specifications Table:-

Power Ratings 110-120V, 1P+N+E, 60HZ, 1.45 kW

Tray Capacity Tray Spacing

10, 1/1 GN Gastronorm Pan Capacity. 10, 20″ x 12″, Hotel Steam Pan Capacity. 10, 18″ x 13″ Half Size Sheet Pan Capacity.
74mm / 27/8″

3

Specifications
P12M Proofer / Holding Cabinet

P12M Specifications Table:-

Power Ratings 110-120V, 1P+N+E, 60HZ, 1.95 kW

Tray Capacity Tray Spacing

12, 18″ x 26″ / 460 x 660, Full Size Sheet Pan Capacity. 24, 18″ x 13″ / 460 x 330, Half Size Sheet Pan Capacity. 12, 600 x 400mm Tray Capacity (Optional Kit).
76mm / 3″

4

Installation
Installation Requirements
Important:
Installation shall comply with local electrical, health and safety requirements. It is most important that this proofer / holding cabinet is installed correctly and that the operation is correct before use. If you have any questions regarding the proper installation and / or operation of this proofer / holding cabinet , please

Unpacking

1. Remove all packaging and transit protection including all protective plastic coating from the exterior stainless steel panels.
2. Check the proofer / holding cabinet and supplied parts for damage. Report any damage immediately to the carrier and distributor.
3. Check that the following parts have been supplied with your proofer / holding cabinet:-

Adaptor Brass. Rubber Washer.

USA / Canada Only)

4. Report any deficiencies to the distributor who supplied the appliance.
5. Ensure that all the castors are fitted securely.
6. Check that the available electrical supply is correct to as shown on the Technical Data Plate located on the front right hand side panel.

– Refer to `Specifications’ section for details.

Location
1. Position the proofer / holding cabinet in its working position.
2. The proofer / holding cabinet should be positioned so that the control panel and shelves are easily reachable for loading and unloading.

Clearances

To ensure correct ventilation for the motor and controls,

the following minimum installation clearances are to be

adhered to:-

Top

0 mm / 0″.

Rear

0 mm / 0″.

Left-hand side 0 mm / 0″.

Right-hand side 25 mm / 1″.

Electrical Connection
Warning This proofer / holding cabinet must be earthed/grounded.

Each proofer / holding cabinet should be connected to an adequately protected power supply and an isolation switch mounted adjacent to, but not behind the proofer / holding cabinet and must be readily accessible to the operator. This switch must be clearly marked and readily accessible in case of fire.
Check that the electricity supply is correct to as shown on the Technical Data Plate on the front right hand corner of the proofer / holding cabinet side panel.
The P8 / P10 / P12 Proofer / Holding Cabinets are supplied with electrical cords fitted . Ensure that the appliance is fitted with the appropriate power cord and plug.

Technical Data Plate – Location
5

Installation

Water Connection
1. A cold water supply should be connected to the water inlet located on the rear right hand side of the unit..

Water Connection

– Max Inlet Pressure 80psi. 2. Turn `On’ the water supply to check for water leaks.

NOTE:

The Prover / Holding Cabinet can be fitted with an optional Water Filter Kit (Part No. 234347). For fitting instructions refer to the Instruction Sheet supplied with the Water Filter Kit.

Positioning of Proofer / Holding Cabinet
Correctly locate the proofer / holding cabinet into its final operating position and lock the front castors to retain the proofer / holding cabinet in it’s location.

6

Operation

Proofer / Holding Cabinet Control Panel

Description of Controls

Control Panel (°F)

Control Panel (°C)

1 2

3 4

5 6

7

1 Power On’ Indicator Light Indicator light illuminates when theFunction’ Switch is turned to ON’ or HOLD’.

2 Function Control

I

Unit is `Off’.

ON

Unit is in Proofing Mode (Power `On’ Indicator

Light illuminates).

HOLD

Unit is in Holding Mode (Power `On’ Indicator Light illuminates).

3 Heating On’ Indicator Light Indicator light illuminates whenThermostat Heating’ is turned ON’ and the elements are cyclingON’ to maintain set temperature.

4 Thermostat Control

Controls air temperature in the Proofer / Holding Cabinet.

Temperature Range – 0 – 85°C / 32 – 185°F.

Proofing Range –

20 – 40°C / 65 – 105°F.

Holding Range –

65 – 85°C / 150 – 185°F.

5 Humidity On’ Indicator Light Indicator light illuminates whenHumidity Control’ is turned ON’ and elements are cyclingON’ to maintain the set humidity. (Controls the cabinet humidity in PROOF Mode only).

6 Humidity Control

Controls humidity level in the proofer / holding cabinet.

Controls the cabinet humidity in PROOF Mode only.

1 to 5

Suggested settings for butter based pastries (Croissants, Danish Pastries etc).

5 to 8

Suggested settings for yeast based breads and doughs.

7 Thermometer
Indicates the cabinet temperature. Dual Centigrade and Fahrenheit scale.

7

FAULT
Proofer not operating
Neon off No heat No Fan Light off No Water in tank
No Humidity
Door does not fully close

Fault Finding

OPERATIONAL FAULTS

FUNCTIONS

OTHER INDICATORS
No Proofer functions possible

CAUSE
Not plugged in

Power supply switch off

Fuse blown or Circuit breaker tripped

Power cord damaged

Function Switch

Proofer switch on

Proofer does not operate

Function Switch

Proofer operates

Neon

Proofer switch on Proofer switch on

Heat Neon on Heat neon off

Element Thermostat Fan motor

Proofer switch on

Lamp

Fuse

Proof switch on

Humidity Neon off

Float switch

Relay

Water solenoid

Proof switch on

Humidity Neon on

No water in tank

Water thermostat

Water Element

Door seal incorrectly fitted

Tray in way of door.

Door not fitted correctly

8

Fault Finding

ITEM
Function Switch
Air Temperature Thermostat (set above Proofer Temperature) Water Thermostat (set above Proofer Humidity) Element
Relay Relay Contacts Fan Motor Float Switch
Water Solenoid

COMPONENT TESTING

CONDITION

TESTING FOR

Proofer power OFF

Continuity through switch when turned on

Voltage at Switch

Check power to switch and power out of switch

REPLACE
If open circuit If no power out

Proofer power OFF

Continuity through thermostat

If open circuit

Voltage at Thermostat Proofer power OFF Voltage at Thermostat Proofer power OFF Voltage at Element

Check power to switch and power out of switch Continuity through switch Check power to switch and power out of switch Continuity Check current draw

If no power out If open circuit If no power out If open circuit If low or zero

Voltage at Relay Coil

Does relay switch

If no

Voltage at Relay Contacts Check power to contacts and power out of contacts If no power out

Voltage at Fan

Does fan rotate

If no

Proofer power OFF

Continuity through switch when float is down

Voltage at Switch Contacts Check power to switch and power out of switch

If open circuit If no power out

Voltage at Solenoid

Solenoid opens

If no

Model

Watts

P8/P10/P12 Water 650W

ELEMENT RESISTANCE & CURRENT

Voltage

Resistance ± 5% @20oC (68oF)

110 — 120V

21

Current ± 5% 5.4A @ 120V

P8 / P10 Dry

700W

110 — 120V

20

5.8A @ 120V

P12 Dry

1200W

110 — 120V

11

10A @ 120V

9

Service Procedures

5.1. Access ………………………………………………………………………………………………. 11 Control Panel—————————————————————————————————— 11 LH / RH Side Access Panels ———————————————————————————— 11 LH / RH Proofer / Holding Cabinet Side Racks ————————————————————– 11

5.2. Replacement ……………………………………………………………………………………… 11 Function Control Switch ——————————————————————————————11 Thermostat Control Switch ————————————————————————————–11 Humidity Control Thermostat ———————————————————————————–12 Thermometer ——————————————————————————————————12 Fan Motor———————————————————————————————————–12 Relay —————————————————————————————————————-12 Fuse and Fuse Holder ——————————————————————————————–12 Water Solenoid —————————————————————————————————-13 Dry Element ——————————————————————————————————–13 Wet Element ——————————————————————————————————-14 Float Switch ——————————————————————————————————–14 Lamp Assembly —————————————————————————————————-15

5.3 Adjustment & Calibration ……………………………………………………………………… 15

Temperature Calibration

15

10

Service Procedures

5.1

Access

5.1.1 Control Panel

1. Remove screw on underside of control panel.
2. Lift control panel up to unhook top of panel from proofer / holding cabinet.

Securing Screw

5.1.2 LH / RH Side Access Panels
1. Remove 2 screws on lower corners of side panel.
2. Pull bottom of panel out and away from bottom of proofer / holding cabinet.
3. Pull down on panel to remove.

Securing Screws

5.1.3 LH / RH Proofer / Holding Cabinet Side Racks
Side Racks – P10 a. Lift up and remove side rack out of proofer /
holding cabinet.
Side Racks – P8 / P12 a. Take hold of top and bottom of rack and lift front of
rack upwards to disengage front upper and lower hangar studs. b. Swing rack inwards. c. Take hold of top and bottom rack at centre and lift rear of rack upwards to disengage rear upper and lower hangar studs. Lift rack out of proofer / holding cabinet.
5.1.4 Fan Baffle
1. Remove RH proofer / holding cabinet RH side rack as shown above.
2. Lift Fan Baffle up to unhook from side of proofer / holding cabinet and remove.

5.2

Replacement

5.2.1 Function Control Switch

1. Remove knob from switch spindle. Knob is a push fit.
2. Remove control panel (Refer Section 5.1.1).
3. Remove 2 switch mounting screws and remove switch from control panel.

Securing Screws

4. Remove wires from rear of function control switch, noting their position.
5. Re-assemble in reverse order.

5.2.2 Thermostat Control Switch

1. Remove knob from switch spindle. Knob is a push fit.
2. Remove control panel (refer Section 5.1.1).
3. Remove 2 switch mounting screws and remove switch from rear of control panel.

Securing Screws

4. Disconnect wires from rear of Control Switch, noting their position.
5. Remove RH Rack from proofer / holding cabinet. (refer Section 5.1.3).
6. Remove Fan Baffle. (refer Section 5.1.4).
7. Remove RH access panel (refer Section 5.1.2).
8. Remove phial from holder inside Proofer.
9. Withdraw phial through the proofer / holding cabinet sidewall.
10. Re-assemble in reverse order.

Thermostat Phial

11

Service Procedures

5.2.3 Humidity Control Thermostat

1. Remove knob from switch spindle. Knob is a push fit.
2. Remove control panel (Refer Section 5.1.1).
3. Remove 2 switch mounting screws and remove switch from rear of control panel.
4. Remove RH Side Rack from oven. (refer Section 5.1.3).
5. Remove Fan Baffle. (refer Section 5.1.4).
6. Remove RH access panel (refer Section 5.1.2).
7. Disconnect wires from rear of Humidity Control Thermostat, noting their position.
8. Undo 2 screws and remove plate in proofer / holding cabinet RH side wall.
9. Remove humidity control phial from water element clamp.
10. Withdraw humidity control phial through proofer / holding cabinet side wall.
11. Re-assemble in reverse order.

Securing Screws
Remove Screws and Plate Humidity Control Phial Clamp

5.2.5 Fan Motor

1. Remove RH Side Access

Panel from proofer /

holding cabinet. (refer Securing

Section 5.1.2).

Nut

2. Remove RH Side Rack

from oven. (refer

Section 5.1.3).

3. Remove Fan Baffle. (refer Section 5.1.4).
4. Undo securing nut and remove fan blade.

Fan Mounting Screws

5. Disconnect wires from fan motor.

Disconnect Connections

6. From inside proofer, undo fan mounting screws.

7. Remove motor from proofer.

8. Re-assemble in reverse order.

5.2.6 Relay

1. Remove RH access panel (refer Section 5.1.2).
2. Disconnect wires from relay (note positions).
3. Remove 2 securing screws and remove relay.
4. Re-assemble in reverse order.

Relay Securing Screws

5.2.4 Thermometer

1. Remove control panel (Refer Section 5.1.1).

Remove Screws and Bracket

2. On rear of control panel, undoing thumbscrews and remove bracket and thermometer.

3. Remove RH Side Rack from proofer. (refer Section 5.1.3).

4. Remove Fan Baffle. (refer Section 5.1.4).

5. Remove RH access panel (refer Section 5.1.2).

6. Remove phial from holder inside proofer.

7. Withdraw phial through

proofer / holding cabinet sidewall.

Humidity Control Phial

8. Re-assemble in reverse order.

5.2.7 Fuse and Fuse Holder
The fuse holder is located on rear panel, just above power entry point. To access fuse, unscrew centre of holder and withdraw fuse.

1. Remove RH access panel (refer Section 5.1.2).

Fuse Holder

2. Disconnect connections from rear of fuse holder.
3. Push fuse holder out of rear panel.
4. Re-assemble in reverse order.
12

Rear of Fuse Holder

Service Procedures

5.2.8 Water Solenoid
1. Turn Off water supply to proofer / holding cabinet.
2. Remove RH access panel (refer Section 5.1.2).
3. Disconnect wires from water solenoid.

4. At rear of proofer / holding cabinet, on top left of rear panel, slacken screw on rear lip.
5. Remove 2 screws securing bracket to proofer.
6. Remove 2 screws securing water solenoid to bracket.
7. Pull down and out to remove bracket from rear of proofer.
8. Disconnect water hose at inlet to proofer. (This is a push fit connection).
9. Remove water solenoid and replace.

Water Solenoid Slacken Screw
Remove Screws

13. Refit and tighten screws securing water solenoid to mounting bracket.
14. Secure mounting bracket to rear of proofer.
15. Tighten screw at top LH corner of proofer.

Tighten this Screw Refit Screws Refit Screws
Mounting Bracket

16. Connect hose from water solenoid to proofer inlet at bottom of proofer. (This is a push fit connection).
17. Re-connect water supply to proofer.

Water Push-Fit Connection

18. Connect electrical connections to water solenoid.
19. Refit and secure RH access panel.

10. Insert replacement water solenoid into recess at rear of proofer.

5.2.9 Dry Element
1. Remove RH access panel (refer Section 5.1.2).
2. Disconnect electrical connections to the dry element.

Water Solenoid

11. Refit water solenoid mounting bracket by pushing top of bracket up under top panel lid.
12. Ensure water solenoid inlet is located through hole in bracket.

Water Solenoid

Disconnect Elect Connections
3. Pull back insulation to reveal terminals. Unscrew locking nuts.

L/Hand Terminal

R/Hand Terminal

Ensure Water Solenoid correctly located
13

Service Procedures

4. Remove RH Side Rack from proofer. (refer Section 5.1.3).
5. Remove Fan Baffle. (refer Section 5.1.4).
6. Withdraw dry element from inside proofer / holding cabinet.
7. Re-assemble in reverse order.

Dry Element

5.2.10 Wet Element
1. Remove RH Side Rack from proofer. (refer Section 5.1.3).
2. Remove Fan Baffle. (refer Section 5.1.4).
3. Lift out and remove the water trough.
4. Unscrew and remove humidity control phial from element by loosening and removing clamp. Remove phial from element.

Lift Up and Remove Water Trough
Remove Clamp here

Humidity Control Phial Clamp

5. Remove RH access panel (refer Section 5.1.2).
6. Disconnect electrical connections to the dry element.
7. Pull back insulation to reveal terminals. Unscrew locking nuts.

Disconnect Elect Connections

L/Hand Terminal
8. From inside the proofer, withdraw the element.
9. Re-assemble in reverse order.

R/Hand Terminal

5.2.11 Float Switch

1. Remove Control Panel. (refer Section 5.1.1).

2. Remove RH Side Rack from proofer. (refer Section 5.1.3).

3. Remove Fan Baffle. (refer Section 5.1.4).
4. Lift out and remove the water trough.

Securing Screws

5. Remove 2 screws securing float switch bracket to prover.

Unscrew Lock Nut

6. Unscrew locknut securing float switch to mounting bracket.

7. Remove RH access panel (refer Section 5.1.2).

Float Switch Mounting Bracket

8. Disconnect float switch Disconnect and cut off this end of Plug plug at connector.

9. Cut off plug from float switch end of cable.

10. Pull cable through hole into prover.

11. Remove float switch mounting bracket and lock nut from cable.

From Float Switch

From Relay

12. Fit float switch mount bracket and lock nut onto new float switch cable, ensuring bracket is orientated correctly and tighten up locknut.

Lock Nut

13. From inside prover, feed cable through hole in prover side wall and Float Switch Mounting Bracket out to RH side of oven.

14. Fit supplied 2 Way Cap to terminal ends of float switch cable and connect up plug to connector from relay.

15. Refit float switch mounting bracket and secure with 2 screws.

Securing Screws

16. Refit water trough and check float switch operates in a vertical movement without catching the sides of the water trough.

17. Refit Control Panel. (refer Section 5.1.1).

18. Refit RH Side Rack. (refer Section 5.1.3).

19. Refit Fan Baffle. (refer Section 5.1.4).

20. Refit RH access panel (refer Section 5.1.2).

14

5.2.12 Lamp Assy
1. Remove LH access panel (refer Section 5.1.2).
2. Remove LH Side Rack from proofer. (refer Section 5.1.3).
3. Remove 4 screws securing support frame.
4. Remove support frame, glass lens and gasket.
5. Remove light bulb if required (this is a push fit into housing).

Service Procedures

5.3 Adjustment & Calibration
5.3.1 Temperature Calibration
1. Remove thermostat control switch (refer 5.2.2). 2. Adjust calibration collar located at base of thermostat
shaft. 3. Adjustment of calibration collar by 1° angular will alter
Proofer temperature by approximately 2°C (36°F). 4. To increase temperature, turn thermostat shaft fully
counter-clockwise then turn calibration collar, counterclockwise. 5. To decrease temperature, turn thermostat shaft fully clockwise then turn calibration collar clockwise. 6. Refit thermostat control switch. 7. Turn On power and re-check thermostat calibration.

Screws

Thermostat Shaft

6. Pull back insulation to reveal rear of lamp assy.
7. Disconnect electrical connections on rear of lamp assy.

Calibration Collar

Disconnect
8. Depress spring loaded locking tabs on rear of light assy. Push light assy into proofer and remove from proofer.
9. Re-assemble in reverse order.

Depress Spring Tabs

15

Electrical Schematic
Electrical Schematic P8M / P10 / P12M Proofer Holding Cabinets.
16

Ø
L1

P1

1

P2

2

P3

3

P4

4

FUNCTION SWITCH

HEATING CIRCUIT HUMIDITY CIRCUIT

SWITCH SETTINGS

P1

1

P1

1 P1

1

P2

2

P2

2 P2

2

P3

3

P3

3 P3

3

P4

4

P4

4 P4

4

OFF PROOF HOLD

FUSE 10A

M
FAN MOTOR

LIGHT 2x25W

1

WATER

TANK

P

THERMOSTAT

WATER LEVEL RELAY 2 4 6 8
1 357

N/O

WATER LEVEL FLOAT SWITCH

WATER SOLENOID

WATER TANK ELEMENT 650W 120V

1

HEATING

P

THERMOSTAT

HEATING ELEMENT P8M / P10M 700W 120V
P12M 1200W 120V

N
L2 E

POWER ON INDICATOR

HUMIDITY ON INDICATOR

HEATING ON INDICATOR

Wiring Diagram
Wiring Diagram P8M / P10M / P12M Proofer Holding Cabinets.
17

CONTROL PANEL (BACKSIDE)

2

11

POWER INDICATOR

FUNCTION SWITCH
1 9
10

P3

P2

P1

3

2

1

2
3 6
15

4

P4

HEATING INDICATOR
11
12 4

2

5 DRY / HOLD

THERMOSTAT

(0-85°C)

18

1

3
HUMIDITY INDICATOR
12
13 7
16 8

2

1

WET THERMOSTAT
(30-85°C)

EARTH

14

19

19

21

18

FUSE 10A

30

30

TERMINAL CONNECTOR (015917)

21

29

P8 / P12 ONLY

28 FAN MOTOR

31 20

LIGHT 34 35

LIGHT

34

33

DRY / HOLD ELEMENT
P8M / P10M DRY ELEMENT 120V 700W (234190)

P12M DRY ELEMENT 120V 1200W (234081)
5

29 17
WATER SOLENOID

28

8
WET ELEMENT P8M / P10M / P12M

27 26

WET ELEMENT 120V 650W (234079)

16 17
15 32
8 246
135 7
RELAY

FLOAT SWITCH

24 25
PLUG 2-WAY (017731)

22

23
33
14 32 26
E

13

N

1 P

TERMINAL BLOCK

POWER SUPPLY CORD

Main Assembly

Replacement Parts List

ITEM 1 2
3

PART No.

DESCRIPTION

M234565 DOOR ASSEMBLY P8

M236466 DOOR ASSEMBLY P10

M234566 DOOR ASSEMBLY P12

M235022 RACK WA LH P8

M236520 RACK WA LH P10

M235024 RACK WA LH P12 12-TRAY

M235026 RACK WA LH P12 9-TRAY

M235442 RACK WA LH P8 600×400 TRAY

M235443 RACK WA LH P12 600×400 TRAY

M234324 RACK WA LH P8

M234661 RACK WA LH P12 9-TRAY

M234328 RACK WA LH P12 12-TRAY

M235023 RACK WA RH P8

M236521 RACK WA RH P10

M235025 RACK WA RH P12 12-TRAY

M235027 RACK WA RH P12 9-TRAY

M235440 RACK WA RH P8 600×400 TRAY

M235444 RACK WA RH P12 600×400 TRAY

M234325 RACK WA RH P8

M234662 RACK WA RH P12 9-TRAY

M234329 RACK WA RH P12 12-TRAY

M235445 600×400 RACK CONVERSION KIT P8

M235446 600×400 RACK CONVERSION KIT P12

(from S/N 476955)
(from S/N 476948) (from S/N 476948) (from S/N 476955) (from S/N 476948) (to S/N 476954) (to S/N 476947) (to S/N 476947) (from S/N 476955)
(from S/N 476948) (from S/N 476948) (from S/N 476955) (from S/N 476948) (to S/N 476954) (to S/N 476947) (to S/N 476947)

*RPL C C C D D D D D D D D D D D D D D D D D D D D

*Recommended Parts Level

RPL

Number of Units In-Service

A

1-5

A+B

5-10

A+B+C

10-50

A+B+C+D 50+

18

Replacement Parts List
Main Assembly (continued)

ITEM PART No.

DESCRIPTION

4 M026216 DRAWER WA

M234319 CONDENSATE CHANNEL (P8 / P12) 5
M236599 CONDENSATE CHANNEL (P10)

6 M022758 DOOR CATCH PLATE

M234313 TOP COVER (P8 / P12) 7
M236463 TOP COVER (P10)

M234315 SIDE PANEL (P8)

8 M236464 SIDE PANEL (P10)

M234316 SIDE PANEL (P12)

9 M234216 CASTOR 75mm RIGID RUBBER

10 M234217 CASTOR 75mm SWIVEL RUBBER D/BRAKE

M234856 HINGE SPACER 11
M236299 DOOR GASKET

12 M234447 KNOB INDEXED

M234334 CONTROL PANEL ASSEMBLY (P8M) °F

M234717 CONTROL PANEL ASSEMBLY (P8M) °C

M236526 CONTROL PANEL ASSEMBLY (P10M) °F 13
M236527 CONTROL PANEL ASSEMBLY (P10M) °C

M234335 CONTROL PANEL ASSEMBLY (P12M) °F

M234718 CONTROL PANEL ASSEMBLY (P12M) °C

*RPL D D D C D D D D D D D D D C D D D D D D

*Recommended Parts Level

RPL

Number of Units In-Service

A

1-5

A+B

5-10

A+B+C

10-50

A+B+C+D 50+

19

Replacement Parts List
Main Components
16A

ITEM PART No.

DESCRIPTION

14

M234318 WATER TANK WA (P8 / P12). M236668 WATER TANK WA (P10).

15 M025566 HANGER STUD.

M233863 OVEN LAMP ASSY -MUST ORDER M233884 – (P8 / P12).

M233115 OVEN LAMP LENS – (P8 / P12).

16 M233884 LAMP BULB G9 25W HALOGEN 120V – (P8 / P12).

M233883 OVEN LAMP SEAL – (P8 / P12).

M233884 LAMP BULB G9 25W HALOGEN 120V – (P10).

16A

M236214 OVEN LAMP HOLDER – (P10). M021352 OVEN LAMP GLASS – (P10).

M021353 LAMP FRAME – (P10).

M021354 LAMP GASKET – (P10).

17 M233528 FLOAT SWITCH – CAP WIRED.

18 M234190 DRY ELEMENT 120V 700W (P8 / P10).
M234081 DRY ELEMENT 120V 1200W (P12).

19 M234349 WATER SOLENOID 90° OUTLET 120V.

20

M234668 WATER TUBE 3/8″ ID BLUE 640mm (P12). M234669 WATER TUBE 3/8″ ID BLUE 490mm (P8 / P10).

Not

M025922 ADAPTOR BRASS ¾” BSP. (USA / CANADA ONLY). M021527 WASHER RUBBER. (USA / CANADA ONLY).

21 M234803 FUSE 10A Ø6.3 X 32mm.

22 M234802 FUSE HOLDER 16A 250V.

23 M233870 CABLE CLAMP PA107.

24 M233871 SCREW 3.5×15 Hi-Lo.

25 M022042 FAN BLADE.

26 M025387K MOTOR A67-3038LH-47 (120V).

27 M021535 RELAY 110V. 28 M026160 TERMINAL BLOCK FV110B.

29 M234079 WET ELEMENT 120V 650W.

*RPL
D D D A B A B A A B A B B B B
B D D D A B D D D D
B
C C
B

*Recommended Parts Level

RPL

Number of Units In-Service

A

1-5

A+B

5-10

A+B+C

10-50

A+B+C+D 50+

20

Door Assembly

Replacement Parts List

31B

Top Hinge P10 Only

Top Hinge P8-P12 Only

31C 31A 32
Bottom Hinge P10 Only 31B

31D

33 34 35 30
Bottom Hinge P8-P12 Only 31A

ITEM PART No.

DESCRIPTION

M234571 DOOR HANDLE WA (P8 Only).

30 M236473 DOOR HANDLE WA (P10 Only).

M234535 DOOR HANDLE WA (P12 Only).

31A

M234930

DOOR HINGE SET (P8 – P12 Only). (Includes Top and Bottom Hinge)

31B M236299 DOOR HINGE GASKET (P10 Only). 31C M235851 DOOR HINGE SET TOP (P10 Only). 31D M235852 DOOR HINGE SET BOTTOM (P10 Only).
M234570 DOOR SEAL (P8). 32 M236474 DOOR SEAL (P10).
M234537 DOOR SEAL (P12). 33 M018947 MAGNET CATCH 34 M026604 CATCH CLIP 35 M025600 MAGNET MOUNTING PLATE

21

*RPL D D D
B
B B B B B B B C C

*Recommended Parts Level

RPL

Number of Units In-Service

A

1-5

A+B

5-10

A+B+C

10-50

A+B+C+D 50+

Replacement Parts List
Controls & Water Assembly

ITEM PART No.

DESCRIPTION

234641 CONTROL PANEL LAMINATED P8M °F

234715 CONTROL PANEL LAMINATED P8M °C

37

236586 CONTROL PANEL LAMINATED P10M °F 236587 CONTROL PANEL LAMINATED P10M °C

234642 CONTROL PANEL LAMINATED P12M °F

234716 CONTROL PANEL LAMINATED P12M °C

38 233865 BADGE MOFFAT

39 228132 TUBE CLIP 40 022788 THERMOMETER 41 234737 INDICATOR LED RED 9mm 110-250V BIPOLAR 42 022789 SWITCH – 3 POSITION 43 022787 THERMOSTAT 0-85 DEG C 44 024527 THERMOSTAT 30-85 C 45 234347 FILTER HEAD KIT (INCLUDES ITEM 47) (OPTIONAL) 46 234563 DOUBLE CHECK VALVE (OPTIONAL) 47 234562 FILTER CARTRIDGE (OPTIONAL)
012289 CORD SET 15A 120V 5-15P US, CAN, XP (P8 , P10 ONLY, NOT SHOWN)
52 023100 CORD SET 20A 120V 5-20P US, CAN (P12 ONLY, NOT SHOWN)

*RPL D D D D D D D

*Recommended Parts Level

RPL Number of Units In-Service

A

1-5

A+B

5-10

A+B+C

10-50

A+B+C+D 50+

B D A B A A C D B

D D

22

Appendix 1 – Proofer Door Reversal
Reversing the Proofer Door (P8/P12 Proofer/Holding Cabinet Only)
NOTE:
Refit all screw fasteners using a low-mid strength
thread locking adhesive unless otherwise stated.
Door reversal should only be carried out by a
suitably competent person.
1. Whilst supporting door remove bottom hinge body (two screws) and remove door.
2. Remove top hinge body (two screws). 3. Remove four cover screws covering alternate hinge
holes. Refit cover screws on opposite side. 4. Remove the LH side panel (four screws). When Changing to RH Hinged Door. 1. Remove the LH magnet plate cover screws and clips
from inside LH wall (Do not fit cover screws to old magnet position). 2. Transfer door magnet plate to opposite side. When Changing to LH Hinged Door.

  1. Remove magnet plate and transfer to opposite side.
    Important: Redundant plate holes in LH side wall must be filled to stop steam ingress into wall cavity.
    2. Fit bottom hinge body to top on opposite side, centre hinge on slots.
    3. Whilst holding door in place fit remaining hinge body to bottom, securing door in position.
    4. Ensure door seal is removed and re-fitted with the join in the seal at bottom.
    5. Refit the LH side panel.
    A1