HORMANN EL 71-B Photocells – One-Way Light Barrier Instruction Manual
- June 5, 2024
- HORMANN
Table of Contents
HORMANN EL 71-B Photocells – One-Way Light Barrier
Fitting
See figure 1
Installation
See figures 2 – 9
Cable cross-section max. 0.5 mm2 For operating the transmitter (TX), use:
- 12-24 V~ / 12-24 V–
- 3 V battery (CR2)
Inserting the battery
3 V battery, type: CR2 BG1, lithium
WARNING:
Risk of explosion due to incorrect battery type There is the risk of explosion if the batteries are replaced with an incorrect battery type.
- Only use the recommended battery type.
LED display
Programming
Selecting the channel is absolutely necessary to ensure proper operation.
-
Insert the battery in the transmitter (TX).
The LED DL2 flashes slowly 1 ×. -
Press the P1 button until the LED DL2 flashes.
The display corresponds to the set channel. Depending on the channel, the display is repeated 4 – 8 ×. During this time the channel can be changed. -
Press the P1 button repeatedly until the desired channel is set.
The LED DL2 flashes according to the new set channel. Depending on the channel, the display is repeated 4 – 8 × If the LED DL2 flashes 1 × slowly, the new channel is saved. -
Repeat the process on the receiver (RX). Set the same channel as on the transmitter (TX).
NOTE:
If multiple photocell pairs are being used, program a different channel for
each photocell pair
Technical data
Connecting voltage| 12 – 24 V~ / 12 – 24 V– /
3 V battery, type: CR2 BG1, lithium
---|---
Power consumption| Tx = 40μA battery, Rx = 30mA
Protection category| IP 54
Operating temperature| –20°C – +55°C
Alignment| Automatic
Nominal range| 20 m (with connection cable) 10 m (with battery)
Horizontal mechanical adjustment angle| –90° / +90°
Vertical optical self-adjustment angle| ±7° (20 m) ±13.5° (5 m)
Technology| Relay – N.C.
EU Declaration of Conformity
Manufacturer: Hörmann KG Verkaufsgesellschaft
Address: Upheider Weg 94-98 33803 Steinhagen Germany
The manufacturer above herewith declares under his sole responsibility that
the product
Equipment/system: One-way photocell
Model: EL71-B
Intended use Supplementary safety device for power-operated doors is in
compliance with the essential requirements and other relevant provisions of
the below-mentioned EU Directives when used for their intended use:
- 2014/30/EU (EMC) EU Electromagnetic Compatibility Directive
- 2015/863/EU (RoHS) Restriction of Use of Hazardous Substances
The following standards and specifications have been applied:
- EN 61000-6-2:2005 Electromagnetic compatibility – Immunity
- EN 61000-6-3:2007 + A1:2011 Electromagnetic compatibility – Emission
- EN IEC 63000:2018 Restriction of Use of Hazardous Substances
Any modifications made to the product without our approval will invalidate this declaration. Steinhagen, 09.03.2022
UK Declaration of Conformity
Manufacturer: Hörmann UK Ltd.
Address: Gee Road Coalville LE67 4JW GB-Leicestershire
The manufacturer above herewith declares under his sole responsibility that
the product
Equipment/system: One-way photocell
Model: EL71-B
Intended use Supplementary safety device for power-operated doors is in
compliance with the essential requirements and other relevant provisions of
the below-mentioned EU Directives when used for their intended use:
2016 No. 1091 UK Electromagnetic Compatibility Regulations 2016
2012 No. 3032 Restriction of the use of certain Hazardous Substances 2012
The following standards and specifications have been applied:
- EN 61000-6-2:2005 Electromagnetic compatibility – Immunity
- EN 61000-6-3:2007 + A1:2011 Electromagnetic compatibility – Emission
- EN IEC 63000:2018 Restriction of Use of Hazardous Substances
Any modifications made to the product without our approval will invalidate this declaration. Coalville, 09.03.2022
Read User Manual Online (PDF format)