Continental Edison CECTG4VIX Gas Cooktop User Manual
- June 16, 2024
- Continental Edison
Table of Contents
Continental Edison CECTG4VIX Gas Cooktop
Product Information
Specifications
- Dimensions: B (mm) 580, A (mm) 50, T (mm) 515, C (mm) 50, H (mm) 42, E (mm) 500, C1 (mm) 560, C2 (mm) 490, G (mm) 20, I (mm) 25, J (mm) 5
- Fuel Type: Gas
Product Usage Instructions
Safety Instructions
Before using the product, please read and follow these safety instructions:
Warning: Risk of fire: Do not place objects on the cooking surfaces.
Installation
Follow these steps to install the product:
- Ensure a minimum clearance of 65 cm (with a hood) or 70 cm (without a hood) above the product.
- Ensure a minimum clearance of 42 cm on all sides of the product.
Gas Connection
Follow these steps to connect the gas:
- Use a gas hose with a suitable connector and secure it with a collar.
- Ensure there is a gas valve with a thermocouple.
Product Usage
Follow these steps to use the product:
- To turn on the product, set the position to MAX.
- To adjust the flame intensity, use the MODULER function.
- Place the appropriate size of cookware on the circular area of the burner.
- Do not use a pot that is too small for the burner.
Cleaning and Maintenance
Follow these steps to clean and maintain the product:
- Ensure the product is turned off and cooled down before cleaning.
- Use a non-abrasive cleaner and a soft cloth to clean the surfaces.
- Avoid using excessive water or cleaning agents that may damage the product.
FAQ
Q: Why are the burners not working?
A: There could be several reasons for this issue. Please check the
following:
- Ensure the gas supply is connected properly.
- Check if the gas valves are open.
- Make sure there are no blockages in the gas burners.
Q: Why is the product making noise?
A: The product may make noise during operation. This is normal and does not
indicate a malfunction.
Q: What are the gas consumption rates?
A: The gas consumption rates are as follows:
Gas Type | Consumption Rate |
---|---|
G20 20 mbar | 97-166.7 l/h |
G30 28-30 mbar | 65-127.2 g/h |