AKG Perception Live P3 S Dynamic Cardioid Microphone User Manual

June 17, 2024
AKG

AKG Perception Live P3 S Dynamic Cardioid Microphone

Safety

Risk of damage

Please make sure that the piece of equipment your microphone will be connected to fulfills the safety regulations in force in your country and is fitted with a ground lead.

Description

Introduction

Thank you for purchasing an AKG product. This Manual contains important instructions for setting up and operating your equipment. Please take a few minutes to read the instructions below carefully before operating the equipment. Please keep the Manual for future reference. Have fun and impress your audience!

P 2

  • Dynamic instrument microphone
  • Cardioid polar pattern
  • Carrying case
  • For kick drum, bass amps, wind instruments

P 4

  • Dynamic instrument microphone
  • Cardioid polar pattern
  • H 440 bracket
  • Carrying case
  • For toms, percussion, guitar amps, wind instruments

P 3 S

  • Dynamic instrument microphone with on/off switch
  • Cardioid polar pattern
  • SA 45 stand adapter
  • Carrying case
  • For instruments and backing vocals

P 5 / P 5 S

  • Dynamic vocal microphone with on/off switch
  • Supercardioid polar pattern
  • SA 45 stand adapter
  • Carrying case
  • For solo vocals

Optional Accessories

For optional accessories, refer to the current AKG catalog or folder, or visit www.akg.com. Your dealer will be glad to help.

Application

Connecting the microphone

The microphone provides a balanced output on a 3-pin male XLR connector:AKG-
Perception-Live-P3-S-Dynamic-Cardiod-Microphone \(6\)

You can connect the microphone either to a balanced or an unbalanced microphone input.

  • To connect the microphone to a balanced input (XLR connector), use a commercial XLR cable.
  • To connect the microphone to an unbalanced microphone input (1/4″ jack), use a cable with a female XLR connector and a 1/4″ TS jack plug. Please note that unbalanced cables may pick up interference from stray magnetic fields near power or lighting cables, electric motors, etc. like an antenna. This may cause hum or similar noise when you use a cable that is longer than 16 feet (5 m).

Switching the microphone on/off

Microphones with the name suffix “S” have an on/off switch.

  1. To switch the microphone on, slide the on/off switch toward the front grill (“ON” position)
  2. To switch the microphone off, slide the on/off switch toward the microphone cable (“OFF” position)

To prevent unwanted bursts of noise, be sure to switch the microphone off before connecting or disconnecting the microphone cable.

Cleaning

Microphone

Use a soft cloth moistened with water to clean the surface of the microphone body.

Internal Windscreen

  • Unscrew the front grill from the microphone CCW.
  • Remove the windscreen from the grill and wash the windscreen in soap suds.
  • Allow the windscreen to dry overnight.
  • Replace the windscreen in the front grill and screw the front grill on the microphone CW.

Specifications

P 2
Parameter Details
Polar pattern Cardioid
Frequency range 20 to 16,000 Hz
Sensitivity 2.5 mV/Pa
Recommended load impedance ≥ 2,000 ohms
Max. sound pressure level 157 dB SPL
P 4
Parameter Details
Polar pattern Cardioid
Frequency range 40 to 18,000 Hz
Sensitivity 2.5 mV/Pa
Recommended load impedance ≥ 2,000 ohms
Max. sound pressure level 152 dB SPL
P 3 S
Parameter Details
Polar pattern Cardioid
Frequency range 40 to 20,000 Hz
Sensitivity 2.5 mV/Pa
Recommended load impedance ≥ 2,000 ohms
Max. sound pressure level 144 dB SPL
P 5 / P 5 S
Parameter Details
Polar pattern Supercardioid
Frequency range 40 to 20,000 Hz
Sensitivity 2.5 mV/Pa
Recommended load impedance ≥ 2,000 ohms
Max. sound pressure level 144 dB SPL

This product conforms to the standards listed in the Declaration of Conformity. To order a free copy of the Declaration of Conformity, visit http://www.akg.com or contact [email protected].

Troubleshooting

Problem Possible Cause Remedy




No sound

| Channel or master fader on mixer, or volume control on amplifier is at zero.| Set channel or master fader on mixer or volume control on amplifier to desired level.
Microphone is not connected to mixer or amplifier.| Connect microphone to mixer or amplifier.
Cable connectors are seated loosely.| Check cable connectors for secure seat.
Cable is defective.| Check cable and replace if damaged.
P 3 S, P 5 S: Switch in “OFF” position.| P 3 S, P 5 S: Set switch to “ON” position.


Distortion

| Gain control on mixer or transmitter module not set correctly.| Set gain control to stop distortion.


Microphone sounds dull

| Internal or external windscreen attenuates high frequencies when soiled.| Clean internal or external windscreen.

Microphones · Headphones · Wireless Microphones · Wireless Headphones · Headsets · Electroacoustical Components

For other products and distributors worldwide visit www.akg.com or www.harman.com

Specifications are subject to change without notice.

Printed in China P.R.C.

09/09/9100 U 13040

Frequently Asked Questions

Can I use the AKG Perception Live P3 S for live performances?

Yes, the microphone is designed for live performances, including instruments and backing vocals, thanks to its dynamic cardioid polar pattern and robust construction.

What is the difference between the P3 and P3 S models?

The main difference is that the P3 S model features an on/off switch, allowing for convenient control over microphone operation.

What instruments is the AKG Perception Live P3 S suitable for?

The microphone is suitable for a variety of instruments, including kick drums, bass amps, toms, percussion, guitar amps, and wind instruments.

How do I connect the AKG Perception Live P3 S microphone?

The microphone provides a balanced output on a 3-pin male XLR connector. You can connect it to a balanced input using a commercial XLR cable or to an unbalanced input using a cable with a female XLR connector and a 1/4 inch TS jack plug.

How do I switch the microphone on/off?

Microphones with the S suffix have an on/off switch. To switch the microphone on, slide the on/off switch toward the front grill (ON position). To switch it off, slide the switch toward the microphone cable (OFF position).

How do I clean the AKG Perception Live P3 S microphone?

Use a soft cloth moistened with water to clean the surface of the microphone body. For the internal windscreen, unscrew the front grill, remove the windscreen, wash it in soap suds, allow it to dry overnight, then replace it and screw the front grill back on.

What is the maximum sound pressure level (SPL) the AKG Perception Live P3 S can handle?

The maximum SPL for the P3 S model is 144 dB SPL, making it suitable for capturing loud sound sources without distortion.

Can I use the AKG Perception Live P3 S for recording purposes?

While primarily designed for live performances, the microphone can also be used for recording instruments and vocals in studio settings, providing reliable and high-quality audio reproduction.

Can I use the AKG Perception Live P3 S microphone for outdoor performances?

Yes, the microphone is suitable for outdoor performances, but it's essential to consider factors such as wind noise and proper protection from moisture or extreme temperatures to ensure optimal performance and longevity of the microphone.

What is the recommended distance for miking instruments with the AKG Perception Live P3 S microphone?

The recommended distance can vary depending on the instrument and desired sound, but generally, positioning the microphone a few inches to a foot away from the sound source can provide a good balance of proximity effect and ambient sound pickup.

Can I use the AKG Perception Live P3 S microphone for recording vocals in a studio setting?

Yes, while primarily designed for live performances, the microphone can also be used for recording vocals in a studio environment, especially for backing vocals or situations where the convenience of the on/off switch is beneficial.

What is the frequency response of the AKG Perception Live P3 S microphone?

The frequency range of the P3 S model is from 40 Hz to 20,000 Hz, allowing it to capture a wide range of frequencies with clarity and detail.

Download The PDF link:AKG Perception Live P3 S Dynamic Cardiod Microphone User Manual

Reference:AKG Perception Live P3 S Dynamic Cardiod Microphone User Manual- device.report

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

AKG User Manuals

Related Manuals