MARK-10 Series EK3 Ergonomics Kits Installation Guide

June 5, 2024
MARK-10

MARK-10 Series EK3 Ergonomics Kits Installation Guide
MARK-10 Series EK3 Ergonomics Kits

Thank you!

Thank you for purchasing a Mark-10 Series EK3 Ergonomics Kit. Please read through this Quick Start Guide and the complete force gauge User’s Guide before using this kit.

IMPORTANT SAFETY CONSIDERATIONS

Force gauges are sensitive instruments that must be treated with care. Please review the yellow safety information card included in the box.

LIST OF INCLUDED ITEMS

Qty.| Part   No.| Description| EK3.100| EK3.200| EK3•500
---|---|---|---|---|---
1| M3-100| Force gauge, 100 IbF 150 kgF 1500 N| ✓| –| –
1| M3-200| Force gauge, 200 IbF / 100 kgF / 1000 N| –| ✓| –
1| M3-500| Force gauge, 500 IbF / 250 kgF / 2500 N| –| –| ✓
1| 08-1022| AC adapter body with US, EU, UK, or AUS prong| ✓
1| 08-1026| Battery (inside the gauge)| ✓
1| 09-1165| USB cable| ✓
4| 10-1023| Thumb screw, #6-32 X 1/2| ✓
1| 10-1021| Hex jam nut, #10-32| ✓| –
1| 10-1108| Hex jam nut, 5/16-18| –| ✓
1| AC1003| Double handle grip for Series 3/2| ✓
1| AC1003-1| Single handle grip for Series 3/2| ✓
1| G1019| Padded attachment, square| ✓
1| G1020| Padded attachment, rectangular| ✓
1| G1021| Padded attachment, curved| ✓
1| G1029| Flat attachment, #10-32F| ✓| –
1| G1036| Flat attachment, 5/16-18F| | ✓
1| G1112| Padded attachment, circular| ✓
1| 12-1032| Carrying case, large| ✓

INSTALLING ACCESSORIES

Double and Single Handles

Attach the force gauge to the double handle grip (AC1003) or single handle grip (AC1003-1) by mating the male dowel pin in the cradle to the corresponding hole in the rear of the force gauge housing.

Then, fasten the gauge to the cradle with four included thumb screws (10-1023), as shown at left.

Double and Single Handles

Attachments

Ergonomics attachments G1019, G1020, G1021, G1029, G1036, and G1112 thread onto the load cell shaft of the Series 3 force gauge.

Fasten the attachment onto the shaft, as shown at left.
Do not overtighten the attachment, or load cell damage can occur!

The attachments may freely rotate on the shaft, thereby self-adjusting to the shape of an object. However, if a fixed position is desired, use an included jam nut, as  follows:

Attachments Induction

  1. Rotate the jam nut as high as possible up the load cell shaft.
  2. Rotate the attachment up to the jam nut, then back off until the desired position.
    Tighten the nut against the attachment.
    Friction between the nut and attachment body will prevent the attachment from loosening as shown at left.

INSTALLING MESUR SOFTWARE

MESUR® Lite www.mark-10.com/mesur-lite-download- form/
Free basic data acquisition application, for data tabulation and exporting to Excel.

MESUR®gauge www.mark-10.com/mesur-gauge-download- form/

Data tabulation, graphing, analysis, and reporting, with user-configurable start and stop triggers and other tools. Compatible with all Mark-10 instruments. Free
90-day evaluation.

USB driver
www.mark-10.com/downloads/software-downloads/Mark-10-USB- Driver.zip

For Mark-10 instruments and the model RSU100 RS-232 to USB converter. Required for communication with a PC. Follow the installation instructions provided in the user’s guide.

PC requirements

Compatible with PCs running Microsoft Windows 7 or later. Minimum monitor resolution is 1108 x 758. A USB or RS-232C serial port is required. If USB communication is required, install the Mark-10 USB driver.

LITERATURE & SOFTWARE DOWNLOADS

Download user’s guides, data sheets, software, solid models, and more.

www.mark-10.com/resources

SUPPORT

Mark-10 Corporation
11 Dixon Avenue Copiague, NY 11726
888-MARK-TEN
Tel: 631-842-9200
Email: info@mark-10.com
Web: www.mark-10.com