pdk Pedestalio Outdoor Pedestal Outdoor Controller Wireless User Guide

October 30, 2023
pdk

Pedestalio
Gate Controller and Reader
Quick Start Guidepdk Pedestalio Outdoor Pedestal Outdoor Controller
Wireless View the user manual here:
prodatakey.zendesk.com
www.prodatakey.com
801.317.8802
Part Numbers:
Wireless with Reader: PCW
Ethernet with Reader: PCE
Wireless without Reader: PCWB
Ethernet without Reader: PCEB

Copyright © 2021 ProdataKey Inc. All rights reserved. Pdk, pdk.io, and the ProdataKey logos are trademarked of ProdataKey Inc.

Package Contents

pdk Pedestalio Outdoor Pedestal Outdoor Controller Wireless -
Package

Mounting

  1. Gooseneck Mount – Use the provided kit to mount the pedestal io to a gooseneck bracket (recommended). Place gasket between pedestal io & gooseneck bracket and fasten each of the 4 bolts as shown.
  2. Wall Mounting – Additional hardware may be needed if mounting to a wall.

pdk Pedestalio Outdoor Pedestal Outdoor Controller Wireless -
Mounting

Reader

  1. Reader – The pedestal io comes pre-wired with a keypad reader.
  2. Optional 2nd Reader* for Egress – The pedestal io i/o board has a second terminal that can be used to wire a second reader (optional). Please see the following reference for wiring a reader to the i/o board:

pdk Pedestalio Outdoor Pedestal Outdoor Controller Wireless -
Reader

Required

Red – to ‘+’ (positive) connector
Black – to ‘-’ (negative) connector
Green – to ‘0’ connector
White – to ‘1’ connector
Brown – to ‘L’ connector

NOTE: After wiring, please refer to the Programming section of this Quick Start Guide.
*To order a second reader, please reference part number: RDRGR

Input A / DPS

  1. DPS (Door Position Sensor) – The DPS is mounted on the gate in the desired location with a 22/2 wire running from the DPS to the controller. Wire the DPS to the controller as shown.
  2. Input A – Rule based inputs can be triggered by using the (A) input for something other than DPS. Please note the following: when input (A) receives a negative connection, the input is triggered until the negative is dropped. A rule  can then be setup to trigger any output based on this input trigger.

Input B/Gate Operator

  1. NO – Used as a dry contact to trigger the gate operator. Connect the negative (-) of the 18/2 wire to NO and the positive (+) to C.
    NOTE: Direct power connection may not be possible with all gate motor models.

Output

  1. AUX Device – An AUX device can be connected to the gate controller to be triggered based on specified events in the system. The most typical is a door prop alarm.
    Connect this device as shown above. The O (AUX Output) uses board power to trigger the device, so be sure correct amperage and voltage are available. If a full relay is needed, an AUX relay can be connected to the (O) output to be triggered.

  2. NC/NO Jumper – If the device connected requires power to be triggered then place the jumper between the center pin and NO. If the device requires dropping power to be triggered then place the jumper between the center and NC.

  3. Jumper – If the device needs negative (-) on the trigger leg, then place the jumper between the center pin and (-). If the device needs positive (+) on the trigger, then place the jumper between the center pin and (+).

Maglock/ Exit Device

  1. Optional Gate Maglock – When installing a maglock to secure double gates, it is required to install an exit device at the gate for free egress. Run an 18/2 wire from the maglock to the gate controller, connecting to the maglock as  shown.
  2. Exit Device – Wire the exit device to the controller and maglock as shown with an 18/5 wire (18/3 if non-powered).
  3. Jumper – Use the designated (+) or (-) board voltage out of (NO) and (NC). If jumper is off, the relay is a standard dry contact needing input into common. In this diagram the jumper is placed on (-) side to operate the maglock.

Communication Connection

  1. Wireless WiMac™ – All wireless connections come pre-connected.
  2. Ethernet – Ethernet connected gate controllers accept RJ45 connections. When used, the controller will be assigned a DHCP address. Controllers must be assigned a Static IP address by using the network utility software which can be downloaded at www.prodatakey.com

Power Connection

  1. DC INPUT – Use included 14 VDC, 2 Amp power supply for DC power input. the power supply must be installed indoors. It is recommended to use 16/2 wire. For high voltage applications, use the HV Converter*.
  2. BATTERY – The enclosure will fit most 12 VDC 1.2 Ah – 1.3 Ah batteries measuring approximately 4”L x 1.7”W x 2”H. The battery is connected with supplied leads and is polarity sensitive. Receive up to 8 hrs of battery backup.
    *To order a High Voltage Converter, please reference part number: HVC

Reference

24 VDC Option – For using the pedestal io gate controller in a 24 VDC application refer to wiring diagrams in the Dealer Portal at www.prodatakey.com/resources
Programming – After the pedestal io gate controller has been connected back to the cloud node, access the configuration software as instructed in the programming manual. This manual is available for download through the Dealer Portal  at www.prodatakey.com/resources
Pedestal io Part Number – Wireless with Reader: PCW, Ethernet with Reader:
PCE, Wireless without Reader: PCWB, Ethernet without Reader: PCEB
Single-Gang Ruggedized Reader Part Number – RDRGR
High Voltage (HV) Converter Part Number – HVC