prefer USER’S MANUAL
Dear Customer,
Thank you for buying the electronic, waterproof (IPX6) breast pump Neno
Perfeo, with a touch panel.
Please refer to the user manual before use.
PRECAUTIONS
- Do not use the breast pump during pregnancy – it can cause preterm birth.
- Do not use the pump if you suffer from chronic diseases or hypertension, which could make it painful for you to use.
- Before each use make sure that no part of the breast pump is damaged. Do not use the device if any of its elements are visibly damaged.
- Keep the pump out of reach of children and animals.
- Avoid exposing the device to mechanical damage caused by, for example, dropping it.
- Keep the silicone parts away from hot surfaces, to avoid deforming the material.
- Before storing the expressed milk make sure to clean and sterilize the breast pump each
- Do not clean the device with abrasive cleaners.
- Do not try to repair the breast pump yourself, it will cause a loss of warranty.
- If the breast pump causes you pain and discomfort during use, turn it off and move it away from your breast.
- Do not plug the device into a voltage higher than stated in the specifica
BEFORE FIRST USE
- Connect the breast pump to the power supply. Charge the baor 2 hours.
- Disconnect the parts of the breast pump that will be in direct contact with the breast or milk.
- Unscrew the milk boom the connector.
- Pull the valve down to disengage it from the connector.
- Remove the lid from the funnel and pull the funnel off the joint.
- Remove the gasket cover and gasket from the joint.
- Wash the device components (please refer to the CLEANING AND DISINFECTION sec).
ELEMENTS
See – Figure 1 on page 2
A. Cap
B. Breast shield x2 (21mm & 24 mm)
C. Connector
D. Pumping device
E – Membrane| F. Valve x2
G. Milk bole
H. Bole holder
I. Bole teat
J. Charging cable
K. Bole cap
---|---
DISPLAY ICONS
See – Figure 2 on page 2
- Power BuHold the buor 2 seconds to turn the device on or off.
- Mode change buPress this device opera there are 3 opera modes of the device (seeding, milk dona). The machine will automa go from the sge mode a 2 minutes.
- Changing the survey – Press the “+” (G) to increase the suc or the “-” (A) to decrease the suc. (SC): levels L1-L9; Deep pumping mode (D): levels L1-L9; Milk mode (E): levels L1-L9).
- Ba Status (F) – The ba icon shows the ba charge status. Connect the device to charge when the ba is low.
- Device opera This indicator shows how many minutes have passed since the breast pump was turned on. The device will automa turn off 30 minutes.
- Sucevel (I) – This shows the currently selected survey.
CLEANING AND DISINFECTION
Cleaning and sanie are two different things. They need to be done separately,
to protect your child and to ensure proper funcf the breast pump.
Cleaning – cleaning the surface and gef stains and dirt.
Sani– gef the bacteria and viruses that can be present on the surface of the
device.
| Breast shield| Breast pump elements (connector, suction bowl, suction cap)|
Bottle and teat set
---|---|---|---
Before first use| Clean and sanitize| Clean and sanitize| Clean and sanitize
After every use| Clean| Clean| Clean
Once a day| Sanitize| Sanitize| Sanitize
NOTE: The pumping device, charging cable, and charging adapter must not
be washed or sanded in water.
NOTE:
- Separate and wash all parts of the device that come into contact with milk immediately a using the device. Thanks to this, you will remove the sediment from the milk and prevent the growth of bacteria.
- Use only potable tap water for cleaning. Use water if your tap water does not meet this requirement.
- When cleaning valves, do not use brushes. Be careful not to pierce the valve through.
- Disassemble, wash and rinse all parts of the breast pump that come into contact with the milk, except the pumping device.
- Use a mild dishwashing liquid or soap when washing the breast pump parts.
See – Figure 3 on page 2
1. Washing (before first use and use – in the sink):
a. Rinse all disconnected parts (that have come into contact with breast and
milk) in cold water to rinse out any milk residue and sediment.
b. Soak in warm soapy water for 5 minutes, then wash and rinse.
c. Let the elements dry naturally. Keep the dry parts of the device cool and
in a dry place when not in use.
ASSEMBLY OF THE BREAST PUMP
- Wash your hands thoroughly with soap and water before touching the breast pump and breast.
- Connect the diaphragm and the pumping device to the coupling.
- Connect the funnel to the connec
- Place the valve in the joint.
- Screw the boe by turning it clockwise un
Advice:
a. Before each use, check if the parts of the breast pump are not damaged. If
necessary replace damaged parts with new ones.
b. Always check the cleanliness of components before using the device.
c. To avoid damaging the breast pump, make sure all its parts are dry before
ge
CHARGING THE BREAST PUMP
Before the first use, charge the breast pump for 2 hours by connecting the
supply using the USB cable. The ba icon on the display will be full when
charging is complete.
Full blinking ba – low ba, connect the device for charging.
Incomplete blinking ba – ba connected to charging, current charging status the
ba.
Full Ba – Ba fully charged
The breast pump can be used while the device is connected to charging. Your
device’s ba will be charged when you connect it to power. The device ba will
not be charged while the pumping device is turned on.
Fully charge the ba of the breast pump before storing it if you intend not to
use the device for a long period of ge the device ba before it is completely
drained. This extends the ba life. If the breast pump has been stored in a hot
place, the ba of the device may not work at first. Allow the breast pump to
cool down for an hour before using it.
USING A BREAST PUMP
See – Figure 1 on page 2
-
Place the funnel over the breast with the nipple inside the drainage channel.
-
Press the funnel and connect the breast pump to your breast using your thumb and index finger.
Support your breast with your hand. -
Turn on the breast pump by pressing the power you.
-
Press the power buff the breast pump use and place the lid on the funnel to protect the device from dust.
a. The breast pump starts to work in the convenient survey for you using the +/- bode – Fast pumping that mimics your baby’s natural suckling of milk from the breast to s.
b. A 2 minutes, the breast pump will automa enter the deep pumping mode. Adjust the survey using the +/- bevel that is comfortable for you. If milk starts to flow from your breast within two minutes, press the Mode Shiu to enter feeding mode.
Deep Pumping Mode – Slower pumping that draws milk gently and efficiently from your breasts.
c. In feeding mode, increase the suc unyou feel slight discomfort (not pain) and reduce the suc power by one degree.
Mixed Mode – mimics the baby’s suckling pay programming the speed and power of the suit can be used a pumping to help empty the breast and increase lactate
MILK PREPARATION
- Do not defrost frozen milk in a microwave oven or in boiling water. It may burn the baby’s mouth.
- Thaw the milk in the refrigerator overnight. Do not re-freeze thawed milk once. You can defrost the milk quickly by keeping it under running water at a maximum temperature of 37 ° C.
- Place the closed of warm water for 20 minutes to bring the milk to body temperature.
- Do not add freshly drained milk to previously frozen milk if the amount of fresh milk exceeds the amount of previously frozen milk.
A a. It is recommended that you breastfeed your baby before you start breeding your baby.
b. Always check the bo components before and after each feed. If the teat is damaged, stop using it immediately.
c. To avoid the risk of suffocaf the baby, test the strength of the nipple by gently pulling on the protruding part.
d. Do not try to enlarge the opening in the nipple.
e. Babies should not be bored without adult supervision.
f. The bo to soothe your baby.
LONG-TERM STORAGE
The breast pump has a built-in ba. To protect against damage, the device goes
into storage mode a long period of in. To disable storage mode, connect the
device to power and charge it for 2 hours. Before you put the breast pump down
for an extended period of e sure that:
a. All parts of the breast pump are clean.
b. You have cleaned the pumping equipment.
c. Device ba is fully charged.
FAQ
The device does not start up:
Make sure the breast pump is connected to a working electrical socket. If the
breast pump has no power source, the display will not turn on and no error
message will appear.
The device does not pump when turned on:
Make sure the device has a charged ba or is connected to a power source.
No / Poor Suc
Make sure that all parts of the breast pump are correctly posiTake the breast
pump apart and make sure that all parts are clean and undamaged. Reassemble
the breast pump according to the instruc ASSEMBLING the breast pump. When
pumping, make sure that the ene surface of the funnel is fully a to the
breast.
More milk has flowed out of the breast than the bo Turn off the breast pump and
disconnect it from the power supply. Use a damp (not wet) cloth to wipe the
breast pump. Wash the parts of the breast pump with the milk in accordance
with the instruc CLEANING AND DISINFECTION secWhen all the parts of the device
are dry, reassemble them.
SPECIFICATION
Input power: 110-240V 50-60Hz
Output power: 5V 1A
Waterproof: IPX6
Ba capacity and type: 3.7V 1100mAh Li-ion
Dimensions: 80x68x64mm
Weight:183g
DESCRIPTION OF MODES
A. S
L1 – 3kPa; L2 – 8kPa; L3 – 13kPa; L4 – 17kPa; L5 – 19kPa; L6 – 25kPa; L7 –
29kPa; L8 – 31kPa;
L9 – 31kPa;
B. Expression mode:
L1 – 18kPa; L2 – 22kPa; L3 – 26kPa; L4 – 29kPa; L5 – 31kPa; L6 – 36kPa; L7 –
38kPa; b 40kPa; L9 – 43kPa;
C. Mixed mode:
L1 fast – 14kPa; L1 slow 19kPa; L2 fast- 14kPa; L2 slow – 22kPa; L3 fast –
14kPa;
L3 slow – 24kPa; L4 fast – 14kPa; L4 slow – 27kPa; L5 fast – 14kPa; L5 slow –
30kPa;
L6 fast – 14kPa; L6 slow – 34kPa; L7 fast – 14kPa; L7 slow – 37kPa; L8 fast –
14kPa;
L8 slow -19kPa; L9 fast – 14kPa; L9 slow – 42kPa.
Allowable difference is ± 5 kph
WARRANTY CARD
The product is covered by a 24-month warranty.
The terms of the guarantee can be found at https://neno.pl/warranty
Details, contact, and website address can be found at :
https://neno.pl/kontakt
Specificaontents of the kit are subject to change without notice.
We apologize for any inconvenience.
Manufacturer:
KGK Trade sp. z o.o. sp. k.
Ujastek 5b, 31-752 Cracow,
Poland Made in PRC
The crossed-out trash can symbol indicates that unusable electrical or electronic devices, their accessories (such as power supplies, cords), or components (for example batteries, if included) cannot be disposed of alongside household waste. In order to dispose of the devices or their components (for example, batteries) deliver the device to the collection point, where it will be accepted free of charge. The disposal is subject to the recast version of the WEEE Directive (2012/19 / EU) and the Directive on batteries and accumulators (2006/66 / EC). Proper disposal of the device prevents degradation of the natural environment. Information about the collection points of the facilities is issued by the competent local authorities. Incorrect disposal of waste is subject to penalties provided for by the law in force in the given area.
www.neno.pl
inspired by Children, Parents