Application

  • Wall luminaire · Indoor luminaire with velvet white metal housing.
  • Luminaire with light source shielded to the front and metallic inside colour of the reflection surface.
  • Radial light emission 360°.

Product Description

  • Wall luminaire “STUDIO LINE”
  • Luminaire housing made of aluminium, surface colour velvet white inside hue matt copper
  • Synthetic cover, translucent white 2 mounting holes ø 4.5mm
  • Distance apart 190mm
  • 1 cable entry for through-wiring for mains cable
  • Connecting terminals 2.5
  • Earth conductor terminal
  • 2-pole connecting terminal for digital control
  • Complies with flicker requirements by IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit
  • 220-240 V x 0/50-60 Hz
  • DC 196-250 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control
  • Temporary thermal regulation to protect temperature-sensitive components without
  • switching off the luminaire
  • Safety class I
  • c – Conformity mark
  • Weight: 4.5 kg
  • This product contains light sources of energy efficiency class(es)

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547. To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 23.1 W
  • Luminaire connected wattage 25.8 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=40 °C
  • 50 910.6K3
  • Module designation LED-1174/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 3655 lm
  • Luminaire luminous flux 524 lm
  • Luminaire luminous efficiency 20,3 lm/W

Installation

  • LEDs are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • Remove the mounting plate with the LED unit from its packaging.
  • Loosen the black knurled screw (slotted) and remove the round made of synthetic material from the LED unit.
  • Pass the power connecting cable through the cable entry in the mounting plate.
  • Fasten the mounting plate with the supplied fastening material or other suitable fastening material to the installation surface.
  • Establish the earth conductor connection on the earthing screw (1) of the mounting plate.
  • Make the electrical connection to the terminals.
  • Observe the correct configuration of the connecting cable. Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
  • The two connecting terminals marked DA, and DA are provided for digital control purposes.
  • If these terminals are not assigned, the luminaire will work with full light output.
  • Insert the round made of synthetic material back into the LED unit and tighten the black knurled screw (slotted).
  • Unpack the luminaire housing and carefully guide it over the LED unit.
  • The luminaire can be rotated 360° on the mounting plate.
  • Position and align the luminaire housing on the mounting plate and tighten the locking screw on the side.

Cleaning · Maintenance

Clean the luminaire regularly with solvent-free cleansers from dirt.

  • Replacing the LED module ·
  • Replacing the power supply unit
  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
  • The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system from the power supply.
  • Loosen the locking screw on the side and lift the luminaire housing off the mounting plate.
  • Loosen the black knurled screw (slotted) and remove the round made of synthetic material from the LED unit.
  • Disconnect the earth conductor connection and the electrical connection to the terminal.
  • Loosen the mounting screws of the power supply unit, the round blank bracket and earthing screws (Torx).
  • Remove the pot with an LED module. Install the replacement pot.
  • Please follow the installation instructions for the
  • LED module.
  • Replace defective LED power supply unit.
  • Install in reverse order.

Spares

  • Synthetic cover 15 000 650B2
  • LED power supply unit DEV-0305/500i
  • LED module 3000 K LED-1174/930
  • Round blank Ø 500 71 003 452 B19
  • Round blank Ø 400 75 004 767

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals