BEGA 13342 Curved Metal Wall Shield Instruction Manual
- June 4, 2024
- BEGA
Table of Contents
BEGA 13342 Curved Metal Wall Shield Instruction Manual
Instructions for use
Application
A curved metal wall shield for colour accentuating an individual luminary on
the wall, or for use in creative luminary arrangements in groups or rows.
Wall shield for complementary installation with BEGS ring wall luminaries.
Product description
Metal wall shield, curved, surface Colour velvet brass, for installation above
the housing of a ring wall luminary Ø 590mm
Locking head made of synthetic material for screwing onto the threaded bolt of
the wall shield
Mounting plate with locking bracket made of synthetic material
Two elongated mounting holes Width 4.6mm · 84mm spacing
Alternative:
Two elongated mounting holes Width 4.6 mm · Spacing 56 mm
Drilling template made of synthetic material enclosed c – Conformity mark
Weight: 1.6 kg
Safety
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminary, the person responsible
for these modifications shall be considered the manufacturer.
Please note: The installation of a wall panel should always be carried out after the installation of the luminary.
Installation
Remove the curved wall shield, locking head and mounting plate with locking
retainer from their packaging.
Screw the locking head made of synthetic material clockwise and hand-tight
onto the threaded bolt on the back of the wall shield with the flat side
facing forward.
Then unscrew the locking head anti-clockwise by 2 mm.
To prevent damage to the surface, place the wall shield on a soft surface.
Make sure that the mounting plate and locking retainer are precisely
positioned for the installation of the wall shield.
To do so, use the enclosed drilling template made of synthetic material.
Place the drilling template on the round luminary housing.
If necessary, a small spirit level may be placed on either of the flat sides
of the drilling template.
The tip of the drilling template can also be used to mark the position.
Press the mounting plate into the upper position of the drilling template at a
right angle.
Place the drilling template on the round luminary housing according to the
orientation of the luminary.
IMPORTANT : Make sure that the concealed NYM cable is not damaged by the
bore holes.
Once interlocked with the mounting plate, the drilling template can be rotated
to allow alternative drilling of holes, adapted to the wall surface.
The central position of the wall shield remains principally ensured.
Mark the outer fastening points of the drilling template on the installation
surface. Drill Ø 6 mm holes in the installation surface and insert the dowels.
Remove the drilling template from the mounting plate. The drilling template is
no longer needed and can be discarded.
Screw the mounting plate onto the wall (outer elongated holes).
Take the wall shield and slot it onto the luminaire housing from above (or from the side) behind the wall luminaire. The round cut-out in the wall shield defines its correct positioning. Slot the wall shield into the locking retainer of the mounting plate parallel to the wall by pressing on its middle.
NOTE: If the wall shield does not slot neatly into the locking retainer (e.g. due to an uneven wall surface), carefully remove the wall shield and slightly unscrew the locking head at the back. Reinstall the wall shield.