BEGA 85156 Performance Flood Light Instruction Manual

June 1, 2024
BEGA

bega-logo

BEGA 85156 Performance Flood Light

Product Information

Specifications

  • Model : Performance Floodlight
  • Power : 150W
  • Dimensions : 85mm x 156mm x 245mm
  • Colour Temperature: 3000K – 4000K
  • Luminous Flux: 5145 lm – 5220 lm
  • Colour Rendering Index (CRI): >90
  • Luminous Efficiency: 95.8 lm/W – 97.2 lm/W

Product Usage Instructions

  • Safety Instructions
    The installation and operation of this luminaire should only be done by a qualified electrician in compliance with national safety regulations. The manufacturer will not be liable for damage resulting from improper use or installation.

  • Overvoltage Protection
    The luminaire’s electronic components are protected against overvoltage as per DIN EN 61547. For additional protection against transients, it is recommended to use separate overvoltage protection components available on the manufacturer’s website.

  • Maintenance
    Regularly check the connecting cable for any external damage and have it replaced by a qualified electrician if necessary. Do not remove the desiccant bag from the luminaire housing as it helps in removing residual moisture.

  • Accessories
    Optional accessories like optical filters and shields are available for this product. Separate instructions for using these accessories can be provided upon request.

Dimension

BEGA-85156-Performance-Flood-Light-fig- \(1\)

Instructions for use

Application

  • Performance floodlight with G½ mounting bush.
  • The floodlight can be bolted together with any female thread G½ according to ISO 228 supplied by others or to BEGA accessories.
  • For a variety of interior and exterior lighting applications.

Product Description

  • Luminaire made of aluminium alloy, aluminium and stainless steel
  • BEGA Unidure coating technology
  • Colour graphite or silver
  • Clear safety glass
  • Silicone gasket
  • Reflector surface made of pure aluminium
  • BEGA Hybrid Optics
  • Rotation range of floodlight is 350° Swivel range -30°/+95°
  • Mounting bracket with G½ threaded connection
  • Thread length: 14 mm
  • Connecting cable X05BQ-F 5 G 1 mm²
  • Cable length 1 m
  • BEGA Ultimate Driver
  • Complies with flicker requirements in accordance with IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • DALI-controllable
  • Number of DALI addresses: 1
  • Basic insulation is provided between the mains and control cables
  • BEGA Thermal Control
  • Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
  • Safety class I
  • Protection class IP 65
  • Dust-tight and protection against water jets
  • Impact strength IK06
  • Protection against mechanical impacts < 1 joule
  • Conformity mark Wind catching area: 0.028 m²
  • This product contains light sources of energy efficiency class(es) E

Safety
The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Installation

  • Screw the floodlight G½ threaded connection firmly into the on-site G½ female thread or BEGA accessory. G½ threaded connection torque = 40 Nm.Secure the screw connection from loosening on site (if provided with locking screw S, see fig. A). Check the earth conductor connection between the G½ threaded connection and the on-site G½ female thread.

  • Adjust floodlight:
    Undo the hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27 mm) and set the desired beam direction (see sketch B, C).

  • Torque:

    • Hexagon socket screw = 7 Nm
    • Hexagon nut = 35 Nm
    • Secure bolted connection G1/2 against loosening by tightening the hexagon socket screws (wrench size 2 mm).
  • The electrical connection must be carried out with matching protection class and safety class, strain-relieved, with suitable connection terminals (not included in the scope of delivery) at the luminaire power supply cable. Note correct configuration of the mains supply cable. The earth conductor is connected at the green-yellow (1), the phase to the brown (L), and the neutral conductor to the blue (N) marked wire. The connection of the control cables is achieved by means of the both leads marked with DALI. In case these leads are not used the luminaire will be operated at full light output.

BEGA-85156-Performance-Flood-Light-fig- \(2\)

  • Lamp
    • Module connected wattage 36.8 W
    • Luminaire connected wattage 40 W
    • Rated temperature ta = 25 °C
    • Ambient temperature ta max = 40 °C
  • 85 156 K3
    • Module designation LED-0780/930
    • Colour temperature 3000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 5145 lm
    • Luminaire luminous flux 3833 lm
    • Luminaire luminous efficiency 95,8 lm / W
  • 85 156 K4
    • Module designation LED-0780/940
    • Colour temperature 4000 K
    • Colour rendering index CRI > 90
    • Module luminous flux 5220 lm
    • Luminaire luminous flux 3889 lm
    • Luminaire luminous efficiency 97,2 lm / W

Light technique

  • Symmetrical wide beam light distribution
  • Half beam angle 25°
  • For special lighting applications, an optical filter can be used to change the symmetrical light cone into a flat beam light distribution.

Cleaning · Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt and deposits. Do not use high-pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Please note:
Do not remove the desiccant bag from the luminaire housing. It is needed to remove residual moisture

Replacing the LED module

  • The designation of the LED module is noted on a separate label in the luminaire or on the underside of the specific LED module.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.

Disconnect the system.

  • Open the floodlight:

    • Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of the floodlight housing.
    • Remove the trim ring along with the safety glass and reflector by twisting it counterclockwise.
    • Replace LED module.
    • Please follow the installation instructions for the LED module.
    • Inspect and, if necessary, replace the luminaire gaskets.
    • Defective glass must be replaced.
    • Place trim ring with glass and reflector on the floodlight housing in such a way that the notches in the trim ring and floodlight housing align on top to each other.
    • Twist on the trim ring clockwise as far as the stop. Tighten locking pin.

Accessories

  • 71 291 Optical filter flat beam
  • 71 333 Shield
  • 71 338 Cylindrical shield
  • 70 214 Pole cap for pole ø 48 mm
  • 70 248 Pole cap for pole ø 60 mm
  • 70 245 Mounting box
  • 70 252 General fastener
  • 70 280 Tube clamp G½
  • 70 283 Screw clamp
  • 70 379 Crossbeam G½
  • 70 889 Tension belt

For the accessories, separate instructions for use can be provided upon request.

Spares

  • Trim ring graphite with glass 25 000 281
  • Trim ring silver with glass 25 000 282
  • LED power supply unit DEV-0270/1050i
  • LED module 3000 K LED-0780/930
  • LED module 4000 K LED-0780/940
  • Reflector 75 005 098
  • Gasket housing 83 001 579
  • Gasket trim ring 83 002 306

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

FAQ

Q: Can I replace the connecting cable myself?
A: No, the connecting cable must only be replaced by a qualified electrician to ensure safety and compliance with regulations.

Q: What should I do if the luminaire gets damaged?
A: In case of damage, stop using the luminaire immediately and contact a qualified electrician for inspection and repairs.

References