BEGA 23 250.2 Wall Luminaire Instruction Manual

June 1, 2024
BEGA

BEGA 23 250.2 Wall Luminaire

Product Information

  • Specifications:
    • Lamp Module connected wattage: 7.6 W
    • Luminaire connected wattage: 8.8 W
    • Rated temperature: 25 – 40°C
    • Ambient temperature: 25 – 40°C

Product Usage Instructions

  • Safety
    • The installation and operation of this luminaire are subject to national safety regulations.
    • Installation and commissioning should only be carried out by a qualified electrician. The manufacturer does not accept liability for damage caused by improper use or installation.
  • Overvoltage Protection
    • The electronic components in the luminaire are protected against overvoltage according to DIN EN 61547.
    • For additional protection against transients, separate overvoltage protection components are recommended.
    • These can be found on the manufacturer’s website.
  • Installation
    • When mounting or dismantling, maintain a minimum distance of 250 mm between the removable cap and the wall. Avoid touching the light output opening of the LED directly during installation or relamping.

FAQs

  • Q: What should I do if I need spare parts?
    • A: Spare parts for this product include spare glass, LED power supply unit, LED modules in 3000 K and 4000 K, and a gasket. The specific part numbers are 11 002 946 .1R, G DEV-0304/350, LED-0424/930, LED-0424/940, and 83 001 179.
  • Q: What are the different module designations available for this luminaire?
    • A: The available module designations are 23 250.2 K3 and 23 250.2 K4. The details for each are as follows:
    • 23 250.2 K3: Module designation – 2x LED-0424/930, Colour temperature – 3000 K, Colour rendering index – CRI > 90, Module luminous flux – 1260 lm, Luminaire luminous flux – 912 lm, Luminaire luminous efficiency – 103.6 lm/W
    • 23 250.2 K4: Module designation – 2x LED-0424/940, Colour temperature – 4000 K, Colour rendering index – CRI > 90, Module luminous flux – 1330 lm, Luminaire luminous flux – 962 lm, Luminaire luminous efficiency – 109.3 lm/W

DIMENSION

Wall luminaire for indoor use

BEGA-23-250-2-Wall-Luminaire-FIG-1 \(1\)

Instructions for use

Application

  • Wall luminaire · indoor luminaire made of handblown opal glass and metal housing, for all lighting tasks in interior applications.
  • They are ideal for places where a soft and uniform lighting distribution is required.
  • Luminaire with a high protection class.

Product Description

  • Luminaire made of Aluminium, finish Stainless steel
  • Hand-blown opal glass
  • Two elongated mounting holes
  • Width 6mm · 275mm spacing
  • Insulating housing with cable entry for mains supply cable up to ø 10,5 mm, max. 3 x 1,5@
  • Connection terminal 2.5@
  • Earth conductor connection
  • BEGA Ultimate Driver®
  • Complies with flicker requirements by IEEE 1789,
  • DIN IEC/TR 63158, DIN IEC/TR 61547-1
  • LED power supply unit 220-240 V x 0/50-60 Hz
  • DC 176-264 V
  • BEGA Thermal Switch®
  • Temporary thermal shutdown to protect temperature-sensitive components
  • Safety class I
  • Protection class IP 44
  • Protected against granular foreign bodies ≥ 1 mm and splash water Impact strength IK02
  • Protection against mechanical impacts < 0.2 joule
  • – Safety mark
  • – Conformity mark
  • Weight: 1.5 kg
  • This product contains light sources of energy
  • efficiency class(es) D

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage by DIN EN 61547.
  • To achieve additional protection against e.g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 7.6 W
  • Luminaire connected wattage 8.8 W
  • Rated temperature ta=25 °C
  • Ambient temperature ta max=40 °C

23 250.2K3

  • Module designation 2x LED-0424/930
  • Color temperature 3000 K
  • Color rendering index CRI >90
  • Module luminous flux 1260 lm
  • Luminaire luminous flux 912 lm
  • Luminaire luminous efficiency 103,6 lm/W

23 250.2K4

  • Module designation 2x LED-0424/940
  • Colour temperature 4000 K
  • Colour rendering index CRI >90
  • Module luminous flux 1330 lm
  • Luminaire luminous flux 962 lm
  • Luminaire luminous efficiency 109,3 lm/W

Insulation housing

Installation

  • For mounting and dismantling please keep a minimum distance of 250 mm between the removable cap and the wall.
  • LEDs are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.

Open luminaire:

  • Loosen the knob, and remove the cap and glass.
  • Drill mounting holes into the mounting surface – spacing 275 mm.
  • For the mains supply connecting open the insulation housing – pull open – strip mains supply cable max. 15 mm and lead it into the insulation housing – see sketch.
  • Make earth conductor connection and electrical connection.
  • Connect both parts of the insulation housing until they audibly engage.
  • The outer coating of the cable has to be fully enclosed by the compression nipple.
  • Fix the luminaire with enclosed or any other suitable fixing material onto the mounting surface.
  • Place glass into the luminaire housing, close the luminaire with the cap, and screw in the knob into the cap.

Replacement of the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
  • Disconnect the system.
  • Loosen the lateral knob, remove the cap, and take out the glass.
  • Please follow the installation instructions for the LED module.
  • The defective glass must be replaced.
  • Insert glass into luminaire housing, close
  • luminaire with the cap and screw in the knob into the cap.

Spares

  • Spare glass 11 002 946 .1RG
  • LED power supply unit DEV-0304/350
  • LED module 3000 K LED-0424/930
  • LED module 4000 K LED-0424/940
  • Gasket 83 001 179

CONTACT

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

BEGA User Manuals