84 844 Compact Floodlight Bega Unilink - Product Overview
1

Application
Compact floodlight BEGA UniLink® with connection adapter for use in combination with various accessories, e.g. for mounting on trees, pipes or wooden structures.
A separate mains plug must be ordered in order to connect the floodlight to the mains.
The various country-specific mains plugs with 0.5 m connecting cable, as well as extension cables and five-way distribution boxes are available as accessories.

Product description
Floodlight made of aluminium alloy, aluminium and stainless steel BEGA Unidure® coating technology
Clear safety glass
Reflector made of pure anodised aluminium
Rotation range of floodlight 360°
Swivel range -30°/+60° 5 m mains supply cable X05RN-F FEP 2 × 1@ + 1G2,5@ with
BEGA UniLink® plug-in connector
BEGA Ultimate Driver® derungen gemäß IEEE 1789,
Complies with flicker requirements in accordance with IEEE 1789, DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit 220-240 V ~ 50-60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets Impact strength IK07
Protection against mechanical impacts < 2 joule
– Conformity mark
Weight: 1.2 kg
This product contains light sources of energy efficiency class(es) D

Safety
The installation and operation of this luminaire are subject to national safety regulations.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Total load
When assembling your lighting system, please ensure that the max. power consumption of 6 A is not exceeded. Information on power consumption can be found in the instructions for use and data sheets for all BEGA UniLink® luminaires.
Power consumption: 0,04 A

Lamp

Module connected wattage| 3 W
Luminaire connected wattage| 4.1 W
Rated temperature| ta = 25 °C
Ambient temperature| ta max = 50 °C
84 844 K3
Module designation| LED-0488/930
Colour temperature| 3000 K
Colour rendering index| CRI > 90
Module luminous flux| 460 lm
Luminaire luminous flux| 351 lm
Luminaire luminous efficiency| 85,6 lm / W
84 844 K4
Module designation| LED-0488/940
Colour temperature| 4000 K
Colour rendering index| CRI > 90
Module luminous flux| 485 lm
Luminaire luminous flux| 370 lm
Luminaire luminous efficiency| 90,2 lm / W

Light technique
Symmetrical wide beam light distribution Half beam angle 51°
The symmetrical light cone can be modified to resemble flat beam light distribution for special lighting applications by replacing the cover glass.

Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Caution:
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltagefree state.

Installation
Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight.
Torque = 5 Nm.
Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable.
To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50 m from the entry point.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 3 mm) and set the desired beam direction.
Tighten the joint screw.
Torque = 2.5 Nm.

Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.

Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Accessories

The following combination options are available for fitting to floodlights with connection adapter:

71 223 Screw clamp with connection adapter
71 224 Tube clamp with connection adapter
71 225 Lashing strap with connection adapter
71 226 General fastener with connection adapter
71 227 G½ mount with connection adapter
70 755 Shield
70 050 Exchangeable lens flat beam

Country-specific mains plugs with 0.5 m connecting cable

71 180| Plug type F / E: system common in
Germany and Europe
---|---
71 181| Plug type G: system used in Great
Britain (“Commonwealth plug”)
71 182| Plug type J: system common in
Switzerland and Liechtenstein
71 183| Plug type L: system common in Italy and Greece
71 184| Plug type K: system common in
Denmark and Greenland
71 186| BEGA UniLink® Extension cable 5 m
71 187| BEGA UniLink® Extension cable 10 m
71 188| BEGA UniLink® Extension cable 20 m
71 247| Connecting cable 5 m with free line ends
7 1 256| Connecting cable 0.5 m with free line ends
71 189| BEGA UniLink® Five-way distribution box

Spares

Spare glass 14 000 850
LED power supply unit DEV-0303/350
LED module 3000 K LED-0488/930
LED module 4000 K LED-0488/940
Reflector 76 001 042 M
Gasket glass 83 001 652