BEGA 84932K3 Compact Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
84 932
16.23
Technical amendments reserved
Compact floodlight
Instruction Manual
84932K3 Compact Floodlight
Instructions for use
Application
Compact floodlights with G½ connecting thread.
The floodlight can be screwed on by the customer with any G½ female thread
according to ISO 228 or with BEGA accessories.
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel
BEGA Unidure® coating technology
Colour graphite or silver
BEGA Hybrid Optics®
Clear safety glass
Reflector surface made of pure aluminium
Rotation range of floodlight 350°
Swivel range -30°/+125°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control®
Temporary thermal regulation to protect temperature-sensitive components
without switching off the luminaire
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK09
Protection against mechanical impacts < 10 joule
– Safety mark
– Conformity mark
Weight: 5.0 kg
This product contains light sources of energy efficiency class(es) E
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Lamp
Module connected wattage | 96.4 W |
---|---|
Luminaire connected wattage | 108 W |
Rated temperature | ta = 25 °C |
Ambient temperature | ta max = 40 °C |
84 932 K3
Module designation | 4x LED-0800/930 |
---|---|
Colour temperature | 3000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 13400 lm |
Luminaire luminous flux | 8859 lm |
Luminaire luminous efficiency | 82 lm / W |
84 932 K4
Module designation | 4x LED-0800/940 |
---|---|
Colour temperature | 4000 K |
Colour rendering index | CRI > 90 |
Module luminous flux | 13600 lm |
Luminaire luminous flux | 8991 lm |
Luminaire luminous efficiency | 83,2 lm / W |
Lighting technology
Wide beam light distribution
Half beam angle 26°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 30
mm) and set the desired beam direction.
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against
loosening by tightening the hexagon socket
screw (wrench size 2 mm) (see sketch B, C).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable.
Make mains supply connection at the brown (L), blue (N) and green-yellow lead
( ).
The connection of the control cables is achieved by means of the both leads
marked with DALI.
In case these leads are not used the luminaire will be operated at full light
output.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted. The replacement can be carried out by
a qualified person using standard tools.
Disconnect the system from the power supply.
Open the floodlight:
Loosen the back locking pin (hexagon socket wrench size 2 mm) in the trim
ring.
Remove the trim ring along with the safety glass and reflector by twisting it
anti-clockwise.
Replace LED module.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place the trim ring with glass and reflector on the floodlight housing so that
the notches in the trim ring and luminaire housing sit on top of each other.
Twist on the trim ring clockwise as far as the stop. Screw in the locking pin.
Accessories
71 282 | Shield |
---|---|
71 287 | Cylindrical shield |
71 292 | Optical filter flat beam |
71 042 | Adapter for installation on a pole |
70 214 | Pole cap for pole top ø 48 mm |
70 248 | Pole cap for pole top ø 60 mm |
70 249 | Pole cap for pole top ø 76 mm |
70 229 | Pole cap for pole top ø 82 mm |
70 245 | Mounting box · rectangular |
70 280 | Tube clamp |
70 379 | Cross beam |
70 889 | Lashing strap |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite with glass | 25 000 236 |
---|---|
Trim ring silver with glass | 25 000 237 |
LED power supply unit | DEV-0363/700 |
LED module 3000 K | LED-0800/930 |
LED module 4000 K | LED-0800/940 |
Reflector | 75 004 951 |
Gasket housing | 83 002 142 |
Gasket trim ring | 83 002 225 |
BEGA Gantenbrink-Leuchten KG
· Postfach 31 60 · 58689 Menden
· info@bega.com
· www.bega.com
References
Read User Manual Online (PDF format)