BEGA 71 269 Installation Housing Instruction Manual

June 1, 2024
BEGA

BEGA 71 269 Installation Housing

Application
Installation housing for the flush mounting of BEGA swimming pool luminaires in concrete basins with tiling. suitable for: 84 575 · 84 578 · 84 579 · 84 738

Please note:

  • Recommended installation depth approx. 400-700 mm below the water surface.
  • Direct or indirect contact with baser foreign metals via swimming pool water, tools, etc. must be prevented.
  • For water in swimming pools and bathing pools in accordance with DIN 19643 and typical pool water temperatures (max. 40 °C), the installation housing can be used in water with a chloride ion concentration of up to 500 mg/l.
  • The installation housing is not suitable for use in brine pools, sea water pools, or in pools where salt electrolysis disinfection is used.
  • When emptying the pool, it must be ensured that the installation housing is rinsed out and remaining residual water is removed.

Product Description

  • The installation housing is made of electropolished stainless steel Material No.: 1.4404
  • The flange ring is made of electropolished stainless steel for flush mounting in the tile face of the basin wall
  • 6 stainless steel cylinder screws M6x30 and matching gasket rings for the mounting of the flange ring on the installation housing
  • 2 mounting threads M5, spacing 208 mm for mounting the swimming pool luminaire
  • 2 threaded rods with hexagon nuts for fixing at the sheeting
  • 1 internal screw cable gland PG 13.5 with gasket insert for luminaire connecting cable
  • ø 9-11.5 mm
  • 1 hose connection for soft PVC protective hose ø 20 x 3 mm
  • 1.5 m soft PVC protective hose ø 20 x 3 mm 1 hose clamp DIN 3017
  • Belt width 9 mm
  • Clamping range 20-32 mm
  • c  – Conformity mark
  • Weight: 2.5 kg

BEGA-71-269-Installation-Housing-1

Safety

The installation and operation of this accessory are subject to national safety regulations.
The manufacturer accepts no liability for damage caused by improper use or installation. If modifications are subsequently made to the accessory, the person who makes these modifications shall be considered the manufacturer.

Installation

  • Only stainless steel tools may be used for installation and maintenance work.
  • The installation housing is poured when constructing the pool.
  • Avoid contact with low-alloy or unalloyed steels.
  • Important : Do not remove the protective film. It protects the installation housing against contamination during construction.

BEGA-71-269-Installation-Housing-2

The mounting of the installation housing on the casing is carried out with the two enclosed threaded rods, washers and hex nuts. Calibrate the installation housing to the pool casing.
Orient the enclosed drilling template to the mounting position on the outside of the casing, fix it in place and only remove after dismantling the casing.
To pass through the threaded rods, drill two 7 mm holes through the two cut- outs in the template.
Screw in the threaded rods into the two M6 thread inserts of the installation housing and guide the installation housing from behind (cable entry on top) through the two holes in the casing.

Guide washers onto the threaded rod and fasten the installation housing to the casing with hex nuts.

Slide the provided soft PVC protective hose onto the connection pipe and fasten it watertight using the hose clip.
Guide the hose so that the luminaire connecting cable can be pushed in and the basin cannot self-drain.
Seal the end of the hose with an additional hose gland as needed (Accessory 71 266)

Before removing the casing, dismantle the hex nuts and washers and unscrew the two threaded rods from the installation housing.

BEGA-71-269-Installation-Housing-3

Remove the protective film from the installation housing, once the casing is taken out.
Set the flange ring and gasket provided against the basin wall and attach on the installation housing using the cylinder screws (Torx drive T30). Make sure to use the gasket rings supplied.
Tighten the cylinder screws uniformly in crosswise fashion.
Continue the tiling flush to the flange ring of the installation housing.

Cleaning · Maintenance

  • Regular cleaning ensures long-lasting corrosion protection.
  • Only non-abrasive cleaning agents may be used for cleaning the installation housing.
  • Sponges, sponge wipes and fleece cloths made of synthetic material without abrasive grit may be used in the visible area.
  • Brushes with bristles made of natural or synthetic material can be used in the non-visible area.
  • Metal cleaning tools (wire brushes, steel wool sponges, etc.) may not be used.
  • Prevent damage to the electropolished surfaces.
  • When cleaning the pool, the installation housing must not come into contact with acids or cleaning agents that attack metal.
  • Use only stainless steel cleaners suitable for swimming pool use.
  • Do not use high pressure cleaners.

Accessories

  • 71 260 Distribution box for installation in floors or walls. For installing the cables of swimming pool luminaires in safety class III
  • 71 266 Additional hose gland For the accessories a separate instructions for use can be provided upon request.

Spares

  • Hose clip                                                   54 001 827
  • Screw M6x30                                           54 001 828
  • PVC-safety hose ø 20×3                         62 000 250
  • Gasket Flange ring                                  82 000 464
  • Sealing ring 6 x                                        83 000 208
  • Gasket insert Leitung ø 9-11,5 mm      83 000 254

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals