BEGA 84845K3 Compact Projector Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
- Application
- Product Description
- Safety
- Total load
- Lamp
- 84 845K3
- 84 845K4
- Light technique
- Luminaire luminous efficiency 102,8 lm/W
- Overvoltage protection
- Installation
- Cleaning · Maintenance
- Maintenance
- Replacing the LED module
- Accessories
- Spares
- Customer Support
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
BEGA 84845K3 Compact Projector
Application
Compact floodlight BEGA UniLink® with connection adapter for use in
combination with various accessories, e.g. for mounting on trees, pipes or
wooden structures.
A separate mains plug must be ordered in order to connect the floodlight to
the mains.
The various country-specific mains plugs with 0.5m connecting cable, as well
as extension cables and five-way distribution boxes are available as
accessories.
Product Description
Floodlight made of aluminium alloy,
aluminium and stainless steel
BEGA Unidure® coating technology
Clear safety glass
Reflector made of pure anodised aluminium
Rotation range of floodlight 360°
Swivel range -30°/+60°
5m mains supply cable
X05RN-F FEP 2×1@ + 1G2,5@ with
BEGA UniLink® plug-in connector
Complies with flicker requirements in
accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 50-60 Hz
BEGA Thermal Switch®
Temporary thermal shutdown to protect
temperature-sensitive components
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK08
Protection against mechanical
impacts < 5 joule
– Conformity mark
Weight: 1.5 kg
This product contains light sources of energy
efficiency class(es) E
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Total load
When configuring your lighting system, please ensure that the maximum power
consumption of 6A is not exceeded. Information on power consumption can be
found in the instructions for use and data sheets for all BEGA UniLink®
luminaires.
Power consumption of 84 845: 0,07 A
Lamp
Module connected wattage 12.6 W
Luminaire connected wattage 14.7 W
Rated temperature ta=25 °C
Ambient temperature ta max=40 °C
84 845K3
Module designation LED-0623/930
Colour temperature 3000 K
Colour rendering index CRI >90
Module luminous flux 1765 lm
Luminaire luminous flux 1454 lm
Luminaire luminous efficiency 98,9 lm/W
84 845K4
Module designation LED-0623/940
Colour temperature 4000 K
Colour rendering index CRI >90
Module luminous flux 1835 lm
Luminaire luminous flux 1511 lm
Light technique
Luminaire luminous efficiency 102,8 lm/W
Symmetrical wide beam light distribution Half beam angle 46°
The symmetrical light cone can be modified to resemble flat beam light
distribution for special lighting applications by replacing the cover glass.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e.g. transients, etc. we recommend
separate overvoltage protection components.
You can find them on our website at www.bega.com.
Caution:
The BEGA UniLink® plug connectors may only be connected and disconnected in a voltage free state.
Installation
Unscrew the hexagon socket screws (wrench size 3 mm) on the sides of the connection adapter and screw the corresponding accessory to the floodlight. Torque = 5Nm.
Plug the floodlight’s connecting cable into the plug contact of the connecting cable with the country-specific mains plug, or into the distribution box or extension cable.
To ensure a sufficiently low protective conductor resistance (loop resistance), the connecting cable of each luminaire in the system must not exceed a length of 50m from the entry point.
Adjustment of beam direction:
Undo joint screw (hexagon socket head wrench size 5 mm) and set the desired
beam direction.
Tighten the joint screw.
Torque = 2.5Nm
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free
cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
The following combination options are available for fitting to floodlights with connection adapter:
71 223 Screw clamp with connection adapter
71 224 Tube clamp with connection adapter
71 225 Lashing strap with connection adapter
71 226 General fastener with connection adapter
71 227 G½ mount with connection adapter
70 756 Shield
70 055 Exchangeable lens flat beam
Country-specific mains plugs with 0.5 m connecting cable
71180 Plug type F / E: system common in Germany and Europe
71181 Plug type G: system used in Great Britain (“Commonwealth plug”)
71182 Plug type J: system common in Switzerland and Liechtenstein
71183 Plug type L: system common in Italy and Greece
71184 Plug type K: system common in Denmark and Greenland
71 186 BEGA UniLink® Extension cable 5m
71 187 BEGA UniLink® Extension cable 10m
71 188 BEGA UniLink® Extension cable 20m
71 247 Connecting cable 5m with free line ends
71 256 Connecting cable 0.5m with free line ends
71 189 BEGA UniLink® Five-way distribution box
For the accessories a separate instructions for use can be provided upon request.
Spares
Spare glass 14 000 851
LED power supply unit DEV-0136/700
LED module 3000 K LED-0623/930
LED module 4000 K LED-0623/940
Gasket glass 83 001 679
Customer Support
BEGA Gantenbrink-Leuchten KG · Postfach 3160 · 58689 Menden · info@bega.com · www.bega.com 3/
References
Read User Manual Online (PDF format)