BEGA 51190.1K3 Ceiling Light Instruction Manual

June 1, 2024
BEGA

51190.1K3 Ceiling Light
Instruction Manual Light mirror for indoor use
51 190.1

51190.1K3 Ceiling Light

BEGA 51190 1K3 Ceiling Light - feager

Application

Light mirror · Indoor luminaire with velvet black metal housing.
Luminaire with light source shielded to the front and velvet white inside colour of the reflection surface.
Radial light emission 360°.

Product description

Luminaire housing made of aluminium, surface colour velvet black
Inside colour velvet white
Inside synthetic cover, translucent white Mirror made of crystal glass, diameter 400 mm, visible edge polished
4 mounting holes ø 6 mm
Distance 260 mm
2 cable entries for through-wiring for mains cable up to ø 10,5 mm max. 5 x 1.5@
Connection terminal 2.5@
Earth conductor connection
2-pole connecting terminal for digital control
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V x 0/50-60 Hz
DC 196-250 V
DALI-controllable
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
BEGA Thermal Control ®
Temporary thermal regulation to protect temperature-sensitive components without switching off the luminaire
Safety class I
Protection class IP 44
Protected against granular foreign bodies
≥ 1 mm and splash water
– Conformity mark
Weight: 6.1 kg
This product contains light sources of energy efficiency class(es) D

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Safety

The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Lamp

Module connected wattage
Luminaire connected wattage
Rated temperature
Ambient temperature| 27 W
30 W
t = 25 °C
t a max a  = 50 °C
---|---

51 190.1 K3

Module designation
Colour temperature
Colour rendering index
Module luminous flux
Luminaire luminous flux
Luminaire luminous efficiency| LED-1301/930
3000 K
CRI > 90
4200 lm
1652 lm
55,1 lm / W
---|---

Installation

LED are high-quality electronic components!
Please avoid touching the light output opening of the LED directly during installation or relamping.
Remove the luminaire housing (reflector) from the packaging.
Pass the power connecting cable through the cable entry into the luminaire housing.
Secure the luminaire housing to the installation surface with the fixing materials provided or other suitable materials.![BEGA 51190 1K3 Ceiling Light

Note position of application of the luminaire housing “arrow down”.
Connect the earth conductor to the earthing screw ( ) of the luminaire housing.
Remove the mounting plate with LED unit from its packaging.
Loosen 4 Torx screws (T 20) and remove the central service panel from the LED unit.
Loosen earth connection (plug connection) between central service panel and LED unit.
Guide wires of the power connecting cable through the rear opening into the LED unit.
Place the LED unit over the keyholes onto the four threaded bolts of the luminaire housings and turn it clockwise until it stops.BEGA 51190 1K3
Ceiling Light - feager2

Tighten the hex nuts M5 over the keyholes.
Make the electrical connection to the terminals.
Observe the correct configuration of the connecting cable. Connect the live conductor to the brown wire (L) and the neutral conductor to the blue wire (N).
The two connecting terminals marked DA, DA are provided for digital control purposes.
If these terminals are not assigned, the luminaire will work with full light output. Establish the earth conductor connection of the LED unit to the luminaire housing (plug connector).
Make earth connection (plug connection) from the central service panel to the LED unit again.

BEGA 51190 1K3 Ceiling Light - feager3

Place the central service panel back onto the LED unit and fasten using the 4 Torx screws (T20).
Remove the mirror from its packaging.
Place the rear locking bolts of the mirror fastening onto the 3 elongated recesses of the LED unit.
Press on the mirror and turn it clockwise against the resistance until the locking bolts audibly click into their final position.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Defective luminaire cover must be replaced.
Close the luminaire.
Spares

LED power supply unit
LED module 3000 K
Reflector
Mirror| DEV-0305/700i
LED-1301/930
75 005 080
75 005 089
---|---

BEGA Gantenbrink-Leuchten KG
· Postfach 31 60 · 58689 Menden
· info@bega.com · www.bega.com

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals