BEGA 85104K3 Garden Flood Light Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
Garden floodlight
BEGA UniLink® Play
85 104
IP 65
Instructions for use
Application
Portable double garden floodlight BEGA UniLink ® Play with infinitely
adjustable mounting height and 2 m connecting cable with plug connector.
For the effective illumination of plants and smaller trees or objects in
private gardens.
Connecting the floodlight requires a power supply unit (71 321), which must be
ordered separately.
In addition, by combining with the Smart Link 71 327, the floodlight and other
UniLink® Play luminaires of this power path can be conveniently switched and
dimmed via the free BEGA Smart app.
BEGA UniLink ® Play is a system for smart garden lighting that is controlled
via app, remote control or automation.
All connection cables and components are installed above ground in the area of
use.
Thanks to the IP 67 standard, they are weatherresistant year-round and highly
durable.
After successful electrical connection, they can be configured in the BEGA
Smart app.
Product description
Luminaire housing made of cast aluminium
BEGA Unidure® coating technology Colour graphite
Vertical tube aluminium anodised Polymer lens
Floodlight horizontally adjustable by 360°, tilt adjustable by ± 90° and
infinitely vertically adjustable
Tool-free plug-on shield made of synthetic material, rotation range -60°/+60°
2x 2 m mains supply cable with BEGA UniLink® Play Stecker plug Safety class
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule ****– Conformity mark
Weight: 0.55 kg
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
The manufacturer accepts no liability for damage caused by improper use or
installation. If subsequent modifications are made to the luminaire, the
person responsible for these modifications shall be considered the
manufacturer.
Lamp
Module connected wattage | 2x 6.2 W |
---|---|
Luminaire connected wattage | 14 W |
Rated temperature | ta= 25 °C |
Ambient temperature | ta max= 45 °C |
Voltage | 48 V = DC |
Module designation | 2x LED-1388/830 |
--- | --- |
Colour temperature | 3000 K |
Colour rendering index | CRI > 80 |
Module luminous flux | 1630 lm |
Luminaire luminous flux | 1120 lm |
Luminaire luminous efficiency | 80 lm / W |
Light technique
Broad spread light distribution.
Half beam angle 54°
Installation
Press the luminaire with earth spike vertically into the soil until stability
is achieved. If necessary, compact soil around the earth spike.
When the power supply unit is fully loaded, the maximum cable length between
the luminaire and the power supply unit must not exceed 100 m.
Insert the plug of the floodlight into the plug contact of the power supply
unit, Smart Link, distribution box or extension cable and hand tighten.
Do not use tools for the tightening or loosening of the screw connections.
Adjusting the floodlight:
After unscrewing the knurled nut, the luminaire head can be infinitely
adjusted in height and horizontally adjusted by 360°.
In addition, the floodlight can be tilted ± 90°.
Undo the hexagon socket screws (wrench size 2) and set the desired beam angle.
Tighten the hexagon socket screws evenly.
Cleaning · Maintenance
Clean dirt and debris from the luminaire regularly with a clean, soft, lint-
free cloth that is kept damp throughout the cleaning.
If possible, please use water for this, adding a little commercial dishwashing
detergent.
For lacquered surfaces we recommend the use of BEGA Lacquer Care Set 71 179.
Cleaning agents containing solvents and high-pressure cleaners are unsuitable
for cleaning and maintenance.
Maintenance
The connecting cable must be checked for external damage and may only be replaced by a qualified electrician.
Replacing the LED module
The designation of the LED module is noted on a label on the connecting cable.
The light colour and light output of BEGA replacement modules correspond to
those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.
Accessories
71 321| BEGA UniLink ® Play
power supply unit
Primary: 220 V-240 V y 50/60 Hz
Secondary: 48 V DC · 0-100 W
---|---
71 322| BEGA UniLink ® Play
Extension cable 5 m
71 323| BEGA UniLink ® Play
Extension cable 10 m
71 324| BEGA UniLink ® Play
Extension cable 20 m
71 325| BEGA UniLink ® Play
Five-way distribution box
71 326| BEGA UniLink ® Play
Two-way distribution box
71 327| BEGA UniLink ®
Play Smart Link
For the accessories a separate instructions for use can be provided upon request.
Spares
LED module 3000 K Gasket| LED-1388/830
83 002 251
---|---
BEGA Gantenbrink-Leuchten KG
· Postfach 31 60 · 58689 Menden
·info@bega.com ·
www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>