BEGA 24502K3 Wall Luminaire Instruction Manual

June 12, 2024
BEGA

Technical amendments reserved

Wall luminaire

BEGA 24502K3 Wall Luminair - Wall luminaire

Instructions for use

Application
Wall luminaire with directed light.

Product description

Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure ® coating technology Clear safety glass Silicone gasket Reflector made of pure anodised aluminium 2 mounting holes ø 4.5 mm Distance apart 85 mm
2 cable entries for through-wiring of mains supply cable ø 7-10.5 mm, max. 5 G 1.5@ Connection terminal 2.5@ Earth conductor connection BEGA Ultimate Driver ®  LED power supply unit 220-240 V 0/50-60 Hz DC 176-276 V
DALI-controllable Number of DALI addresses: 1 Basic insulation is provided between the mains and control cables BEGA Thermal Control ®  Temporary thermal regulation to protect temperature-sensitive components without
switching off the luminaire Safety class I Protection class IP 64 Dust-tight and protection against splash water Impact strength IK06 Protection against mechanical impacts < 1 jouler Safety mark ****Conformity mark Weight: 1.0 kg This product contains light sources of energy efficiency class(es) D, E

Dark Sky
The light from this luminaire is directed evenly and highly efficiently onto the surface to be illuminated and emits less than 1 % of the luminaire luminous flux into the upper halfspace of the luminaire.

Safety
The installation and operation of this luminaire are subject to national safety regulations.
Installation and commissioning may only be carried out by a qualified electrician.
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components. You can find them on our website at www.bega.com.

Lamp
Module connected wattage Luminaire connected wattage Rated temperature Ambient temperature
24 502 K3
Module designation Colour temperature Colour rendering index Module luminous flux Luminaire luminous flux  Luminaire luminous efficiency
24 502 K4
Module designation Colour temperature Colour rendering index Module luminous flux Luminaire luminous flux  Luminaire luminous efficiency

Installation

LED are high-quality electronic components! Please avoid touching the light output opening of the LED directly during installation or relamping.
Undo the screws and lift off the luminaire top. Lead the mains supply cable through the cable entry of the luminaire base.
Note position of application of the luminaire “arrow down”.
Fix luminaire base with enclosed or any other suitable fixing material onto the mounting surface.
Be sure to use the gasket rings supplied.
Make the earth conductor connection and the electrical connection.
For digital control please use the connecting terminal DA, DA.
In case this terminal is not used the luminaire will be operated at full light output.
In order to guarantee the maximum service life of the electrical components, the enclosed desiccant pouch must be placed in the luminaire.
Remove the desiccant pouch from the foil packaging and place it in the position marked by the red information label immediately before finally closing the luminaire.
Make earth conductor connection between luminaire top and luminaire base.
Make sure that gasket is positioned correctly.
Install the luminaire top, press-on and manually tighten screws evenly.

Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Replacing the LED module
The designation of the LED module is noted on a label in the luminaire.
The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted.
The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire.
Please follow the installation instructions for the LED module.
Inspect and, if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Close the luminaire.

Spares

LED power supply unit| DEV-0312/700
LED module 3000 K| LED-0736/830
LED module 4000 K| LED-0736/840
Reflector| 76 001 145
Gasket| 83 002 177

BEGA Gantenbrink-Leuchten KG ·
Postfach 31 60 ·
58689 Menden ·
info@bega.com ·
www.bega.com

Documents / Resources

| BEGA 24502K3 Wall Luminaire [pdf] Instruction Manual
24502K3, 24502K4, 24502K3 Wall Luminaire, Wall Luminaire, Luminaire
---|---

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>

Related Manuals