BEGA 50693.2 Recessed Ceiling Downlight Instruction Manual

June 12, 2024
BEGA

BEGA 50693.2 Recessed Ceiling Downlight

Product Information

  • Product Name: LED Luminaire
  • Model Number: 50 693.2 K3
  • Color Temperature: 3000 K
  • Colour Rendering Index (CRI): > 90
  • Module Luminous Flux: 1255 lm
  • Luminaire Luminous Flux: 759 lm
  • Luminaire Luminous Efficiency: 77.4 lm / W
  • Lamp Module Connected Wattage: 8.1 W
  • Luminaire Connected Wattage: 9.8 W

Product Usage Instructions

  1. Ensure that the installation and operation of the luminaire comply with national safety regulations.
  2. Installation and commissioning should only be carried out by a qualified electrician.
  3. Improper use or installation may result in damage, for which the manufacturer accepts no liability.
  4. If modifications are made to the luminaire, the person responsible for the modifications is considered the manufacturer.
  5. The luminaire is protected against overvoltage, but additional overvoltage protection components are recommended for enhanced protection.
  6. For the replacement of the LED module, follow these steps:
    • Disconnect the system and open the luminaire.
    • Refer to the installation instructions for the LED module.
    • Replace the module using standard tools.
    • Close the luminaire.
  7. The power supply units provided are suitable for the operation of one LED luminaire.
  8. For accessories, separate instructions for use can be provided upon request.

Spares

  • LED Module 3000 K – Part Number: 75 002 722
  • Reflector – Part Number: 75 002 913
  • Spare Glass – Part Number: 75 002 913

Recessed ceiling downlight for indoor use

BEGA-50693.2-Recessed-Ceiling-Downlight-fig-1

Instructions for use

Application
Recessed ceiling downlight · Interior luminaire with symmetrical narrow beam light distribution for connection to an external LED power supply unit. For surface-mounted installation in indoor suspended ceilings of 5-25 mm thickness.

Product Description
Recessed luminaire without power supply unit Luminaire housing made of cast aluminum Installation housing is made of glass-fiber reinforced polyamide with 2 fastening springs Reflector made of pure anodized aluminum Optical silicone lens

Ceiling trim ring finish, Stainless steel
Partially matt crystal glass

Recessed opening ø 130 mm

  • Required installation depth 95 mm
  • 1 connecting cable with strain relief and plug connector system for BEGA power supply unit, on/off or DALI
  • Safety Class III 3
  • c  – Conformity mark
  • Weight: 1.1 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician. The manufacturer accepts no liability for damage caused by improper use or installation. If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547. To achieve additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.

Lamp

  • Module connected wattage 8.1 W
  • Luminaire connected wattage 9.8 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 55 °C
  • When installed in heat-insulating
  • material ta max = 35 °C

50 693.2 K3

  • Module designation LED-0800/930
  • Color temperature 3000 K
  • Color rendering index CRI > 90
  • Module luminous flux 1255 lm
  • Luminaire luminous flux 759 lm
  • Luminaire luminous efficiency 77,4 lm / W

Lighting technology
Half beam angle 55°

Installation

  • A separate power supply unit is required to operate the luminaire.
  • For connection to the external LED power supply unit – accessory 13 143 or 13 168 – the luminaire is equipped with a 2-pin connector.
  • Note the operating instructions of the LED power supply units.
  • LED are high-quality electronic components!
  • Please avoid touching the light output opening of the LED directly during installation or relamping.

The recessed opening is covered by the frame of the luminaire housing. Fixing the installation housing in the recessed opening is achieved by using two adjustable springs. Installation into inserted ceilings: A recessed opening of 130 mm is necessary to accept the installation housing. Recessed depth min. 95 mm. Compress the fastening springs of the installation housing against their spring pressure on both sides towards the housing and slide the installation housing into the recessed opening. The fastening springs catch the ceiling panel from the backside. The minimum thickness of the ceiling panel is 5 mm. If the minimum thickness of the panel is less than 5 mm it must be reinforced from the reverse side. The maximum thickness of the ceiling panel must be no more than 25 mm.

Connect to the LED power supply unit. Route the LED power supply unit through the installation housing and place it in the suspended ceiling. Connect the 2-pin plug connector between the luminaire and the external LED power supply unit Press together the two internal fixing sliders inside the luminaire housing. Push the luminaire housing to the end of the installation housing and then release the fixing sliders. This mechanism ensures that the luminaire and the housing sit securely inside the installation housing.
Please use the protective gloves provided for the installation to prevent fingerprints on the reflector. Place the reflector with silicone lens onto the glass. Twist the glass with the attached reflector to the right to fix the assembly inside the luminaire housing.

BEGA-50693.2-Recessed-Ceiling-Downlight-fig-2

Cleaning · Maintenance
Clean the luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module
The designation of the LED module is noted on a label in the luminaire. The light color and light output of BEGA replacement modules correspond to those of the modules originally fitted. The module can be replaced by qualified persons using standard tools.
Disconnect the system and open the luminaire. Please follow the installation instructions for the LED module.

Accessories

Power supply units for LED luminaires 220-240 V · 0/50-60 Hz with strain relief and plug connector system.

  • 13 143 Power supply unit on/off
  • 13 168 Power supply unit DALI
  • The power supply units are only suitable for the operation of one LED luminaire.

Accessoires
Blocs d’alimentation pour luminaires LED

  • 220-240 V · 0/50-60 Hz avec collier antitraction et le système de connecteur.
  • 13 143 Bloc d’alimentation on/off
  • 13 168 Bloc d’alimentation DALI
  • For the accessories, separate instructions for use can be provided upon request.