Application

  • Ceiling mounted track spotlight · indoor luminaire for 3-phase Eurostandard-Plus® track systems.
  • The optical system of the washer is swivel-mounted and rotatable.
  • Symmetrical narrow beam light distribution.
  • With BEGA Hybrid Optics®: Highly efficient and low-loss light distribution, thanks to reflector and optical lens.

Product Description

  • Track spotlight with adapter
  • Cast aluminium luminaire housing, finish Colour velvet black,
  • Polycarbonate track adapter with integrated
  • LED power supply unit
  • Trim ring · Chrome finish
  • Clear safety glass
  • Optical silicone lens · BEGA Hybrid Optics®
  • Reflector surface is made of pure aluminium
  • LED power supply unit 220-240 V y 50/60 Hz
  • DALI-controllable
  • Basic insulation is provided between the mains and control cables
  • Safety Class II 2
  • Impact strength IK07
  • Protection against mechanical impacts < 2 joule
    • Conformity mark
  • Weight: 0.9 kg
  • This product contains light sources of energy efficiency class(es) E

Safety

  • The installation and operation of this luminaire are subject to national safety regulations.
  • Installation and commissioning may only be carried out by a qualified electrician.
  • The manufacturer accepts no liability for damage caused by improper use or installation.
  • If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Overvoltage protection

  • The electronic components installed in the luminaire are protected against overvoltage in accordance with DIN EN 61547.
  • To achieve an additional protection against e. g. transients, etc. we recommend separate overvoltage protection components.
  • You can find them on our website at www.bega.com.

Lamp Specification

  • Module connected wattage 12.3 W
  • Luminaire connected wattage 14.5 W
  • Rated temperature ta = 25 °C
  • Ambient temperature ta max = 60 °C

50 964.5 K3

  • Module designation LED-0986/930
  • Colour temperature 3000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1685 lm
  • Luminaire luminous flux 1296 lm
  • Luminaire luminous efficiency 89,4 lm / W

50 964.5 K4

  • Module designation LED-0986/940
  • Colour temperature 4000 K
  • Colour rendering index CRI > 90
  • Module luminous flux 1710 lm
  • Luminaire luminous flux 1315 lm
  • Luminaire luminous efficiency 90,7 lm / W

Light technique

  • Track spot · surface washer with adjustable optical system.
  • Optical system 0-60° swivel-mounted and infinitely rotatable 360° around the vertical luminaire axis.
  • Symmetrical narrow beam light distribution.
  • Half beam angle 16°

Installation

LED are high-quality electronic components!

  • Please avoid touching the light output opening of the LED directly during installation or relamping.
  • The track spotlight with adapter is ready for operation in 3-phase EUROSTANDARD-PLUS® track systems.
  • The mounting is done without tools in the bus bar.

IMPORTANT:

  • Ensure that the adapter’s two lateral stays are located on the same side as the matching guide profile of the track before installing the adapter in the 3-phase EUROSTANDARDPLUS ® track system.
  • To select the phase ( 1 2 3 ) the turning knob on the rear side of the adapter has to be operated accordingly.
  • Screw enclosed trim ring with attached reflector into the luminaire housing by turning it clockwise until it stops, so that it is fixed by clamping.
  • Place the surface washer adapter flush on the conductor rail in the desired position.
  • Push the two fixing levers on the underside of the adapter to the right until they click into their end position.
  • Set the desired LED beam direction by turning and tilting the luminaire housing.
  • Move the two fixing levers in opposite directions until they disengage to unlock the adapter.

Dimension

BEGA-50964.5-LED-Track-Spotlight-fig-1

Cleaning And Maintenance

  • Clean luminaire regularly with solvent-free cleansers from dirt.

Replacing the LED module

  • The designation of the LED module is noted on a label in the luminaire.
  • The light colour and light output of BEGA replacement modules correspond to those of the modules originally fitted. The replacement can be carried out by a qualified person using standard tools.
  • Disconnect the system and open the luminaire.
  • Uninstall the reflector.
  • Please follow the installation instructions for the LED module.
  • Install the reflector. Defective glass must be replaced. Close the luminaire.

Spares

  • LED power supply unit DEV-0438/350
  • LED module 3000 K LED-0986/930
  • LED module 4000 K LED-0986/940
  • Reflector 75 003 702
  • Glass/Trim ring 75 003 796

BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com.