Application

Unshielded luminaire with protective guard and high protection class for installation under ceilings and on walls.

An extremely robust surrounding frame made of die cast aluminium protects the edges and corners of the crystal glass.

Product description

Luminaire made of aluminium alloy
and stainless steel
BEGA Unidure® coating technology
Crystal glass, white inside
2 mounting holes ø 5.5mm
Distance apart 89mm
2 cable entries for through-wiring of mains
supply cable ø 7-10.5mm
Connecting terminal and
earth conductor terminal 2.5@
Lampholder E 27
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK07
Protection against mechanical
impacts < 2 joule
– Safety mark
– Conformity mark
Weight: 4.2 kg

Safety

The installation and operation of this luminaire are subject to national safety regulations. Installation and commissioning may only be carried out by a qualified electrician.\
The manufacturer accepts no liability for damage caused by improper use or installation.
If subsequent modifications are made to the luminaire, the person responsible for these modifications shall be considered the manufacturer.

Lamp
Luminaire with screw base E 27
Lamp output max. 100 W
This product contains light sources of energy efficiency classes E, F

Supplied lamp
BEGA LED lamp 13590
LED Retrofit 12 W · 1400 lm · 3000 K

Luminaire efficiency: 50%

Additional BEGA LED lamps are available for this luminaire:

13 584 LED 7 W · 805 lm · 3000 K
13 586 LED 7 W · 805 lm · 3000 K dimmable
13 588 LED 8 W · 1055 lm · 3000 K
13 592 LED 12 W · 1400 lm · 3000 K dimmable

Radio-controlled version (Zigbee 3.0):

13 555 LED 9 W · 805 lm · 2700 K dimmable
13 556 LED 9 W · 805 lm · 2700-6500 K dimmable · tunable white
13 557 LED 9.5 W · 805 lm · 2700-6500 K dimmable · tunable white · RGBW

Detailed technical and lighting data for the lamps can be found in the data sheets on our website.

Installation

Undo screws.
Remove protective guard and glass with gasket.
Lead the mains supply cable through the cable entry into the mounting surface.
In case of wall installation note position of application »arrow down«.
Fix luminaire back housing with enclosed or any other suitable fixing material onto the mounting surface.
It is absolutely essential to use the enclosed gaskets.
Make earth conductor connection.
Push silicone sleeves over the lines and make electrical connection.
Insert lamp.
Insert glass with gasket and protective guard.
Make sure that gasket is in correct position.
Tighten screws evenly.

Relamping · Maintenance

Disconnect the electrical installation.
Open the luminaire and clean.
Use only solvent-free cleaning agents. Change the lamp.
Check the gasket and replace, if necessary.
Close the luminaire.
For cleaning, do not use high pressure cleaners.

Spares

Spare glass 11 002 288 11
LED lamp 3000K 13 590
Lampholder 63 000 052

Customers Support

BEGA Gantenbrink-Leuchten KG
Postfach 3160
58689 Menden
info@bega.com
www.bega.com

References

Read User Manual Online (PDF format)

Read User Manual Online (PDF format)  >>

Download This Manual (PDF format)

Download this manual  >>

Related Manuals