BEGA 85167 RGBW Performance Floodlight Instruction Manual
- June 1, 2024
- BEGA
Table of Contents
Technical amendments reserved
Performance floodlight
85 167
Instructions for use
Application
Performance floodlight with G½ mounting bush.
The floodlight can be bolted together with any female thread G½ according to
ISO 228 supplied by others or to BEGA accessories.
For a variety of interior and exterior lighting applications.
The floodlight can be controlled by DALI colour light control (DT8, RGBWAF,
xy, TC).
Product description
Luminaire made of aluminium alloy, aluminium and stainless steel BEGA Unidure®
coating technology Colour graphite or silver Safety glass with optical
structure Silicone gasket
Reflector surface made of pure aluminium BEGA Constant Optics®
Rotation range of floodlight 350°
Swivel range -30°/+100°
Mounting bracket with G½ threaded connection
Thread length: 14 mm
Connecting cable X05BQ-F 5 G 1 mm²
Cable length 1 m
BEGA Ultimate Driver®
Complies with flicker requirements in accordance with IEEE 1789,
DIN IEC/TR 63158, DIN IEC/TR 61547-1
LED power supply unit
220-240 V 0/50-60 Hz
DC 176-264 V
DALI-controllable(DT8, RGBWAF, xy, TC)
Number of DALI addresses: 1
Basic insulation is provided between the mains and control cables
Safety class I
Protection class IP 65
Dust-tight and protection against water jets
Impact strength IK06
Protection against mechanical impacts < 1 joule
– Conformity mark
Wind catching area: 0.021 m²
This product contains light sources of energy efficiency class(es) F
Safety
The installation and operation of this luminaire are subject to national
safety regulations.
Installation and commissioning may only be carried out by a qualified
electrician.
The manufacturer accepts no liability for damage caused by improper use or
installation.
If subsequent modifications are made to the luminaire, the person responsible
for these modifications shall be considered the manufacturer.
Overvoltage protection
The electronic components installed in the luminaire are protected against
overvoltage in accordance with DIN EN 61547.
To achieve an additional protection against e. g. transients, etc. we
recommend separate overvoltage protection components.
You can find them on our website at www.bega.com.
Installation
Screw the floodlight G½ threaded connection firmly into the on-site G½ female
thread or BEGA accessory.
G½ threaded connection torque = 40 Nm.
Secure the screw connection from loosening on site (if provided with locking
screw S, see fig. A).
Check the earth conductor connection between the G½ threaded connection and
the on-site G½ female thread.
Adjust floodlight:
Undo hexagon socket screw (wrench size 5 mm) and hexagon nut (wrench size 27
mm) and set the desired beam direction (see sketch B, C).
Torque:
Hexagon socket screw = 7 Nm
Hexagon nut = 35 Nm
Secure bolted connection Gß against loosening by tightening the hexagon socket
screws (wrench size 2 mm).
The electrical connection must be carried out with matching protection class
and safety class, strain-relieved, with suitable connection terminals (not
included in the scope of delivery) at the luminaire power supply cable.
Note correct configuration of the mains supply cable. The earth conductor is
connected at the green-yellow (1), the phase to the brown (L), and the neutral
conductor to the blue (N) marked wire.
The connection of the control cables is achieved by means of the both leads
marked with DALI. In case these leads are not used the luminaire will be
operated at full light output.
Lamp|
---|---
Module connected wattage| 20.8 W
Luminaire connected wattage| 24 W
Rated temperature| ta = 25 °C
Service life criteria| 50 000 h / L70
Module designation| LED-1161/RGBW
Colour temperature of the white LED| 4000 K
Luminaire luminous flux| 1288 lm
Luminaire luminous efficiency| 53,7 lm / W
Light technique
Symmetrical wide beam light distribution Half beam angle 24°
For special lighting applications, an optical filter can be used to change the
symmetrical light cone into a flat beam light distribution.
Cleaning · Maintenance
Clean luminaire regularly with solvent-free cleansers from dirt and deposits.
Do not use high pressure cleaners.
Maintenance
The connecting cable must be checked for external damage and may only be
replaced by a qualified electrician.
Please note:
Do not remove the desiccant bag from the luminaire housing.
It is needed to remove residual moisture.
Replacing the LED module
The designation of the LED module is noted on a separate label in the
luminaire or on the underside of the specific LED module.
The light colour and light output of BEGA eplacement modules correspond to
those of the modules originally fitted. The module can be replaced by
qualified persons using standard tools.
Disconnect the system.
Open the floodlight:
Undo locking pin (hexagon socket head wrench size 2.5 mm) on the back side of
the floodlight housing.
Remove the trim ring along with the safety glass and reflector by twisting it
counterclockwise.
Replace LED module.
Please follow the installation instructions for the LED module. Inspect and,
if necessary, replace the luminaire gaskets.
Defective glass must be replaced.
Place trim ring with glass and reflector on the floodlight housing in such a
way that the notches in the trim ring and floodlight housing align on top to
each other.
Twist on the trim ring clockwise as far as the stop.
Tighten locking pin.
Accessories
71 290 | Optical filter flat beam |
---|---|
71 332 | Shield |
71 337 | Cylindrical shield |
70 214 | Pole cap for pole ø 48 mm |
70 248 | Pole cap for pole ø 60 mm |
70 245 | Mounting box |
70 252 | General fastener |
70 280 | Tube clamp G½ |
70 283 | Screw clamp |
70 379 | Cross beam G½ |
70 889 | Tension belt |
For the accessories a separate instructions for use can be provided upon request.
Spares
Trim ring graphite
Trim ring silver
LED power supply unit
LED module
Reflector
Gasket housing
Gasket trim ring| 25 000 279
25 000 280
DEV-0418/200i
LED-1161/RGBW
76 002 013
83 000 521
83 001 952
---|---
BEGA Gantenbrink-Leuchten KG · Postfach 31 60 · 58689 Menden · info@bega.com · www.bega.com
References
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>