DOMETIC SPX1200T-T-RE Roof Top Evaporator Unit Owner’s Manual
- June 17, 2024
- Dometic
Table of Contents
DOMETIC REWORK KIT SERVICE MANUAL
Equipment Included: Please check below
SPX1200T-T-RE Roof Top Evaporator Unit
Recommended Tools:
Work gloves,
Screwdriver with bit attachment
Allen 3mm bit
Torx 25 Bit
Socket wrench 8mm
Side cutter
Soap water
Soft cloth
Time Required: 25 Min
Recommended number of people: 1
Product Suitable For: SPX1200T-T-RE (SKU 9600026439)
RELATED DOCUMENTS
You find this service manual in more languages online at qr.dometic.com/beaLE2.
EQUIPMENT INCLUDED
- 2 pcs. Sealing tape (50503mm) (1)
- 3 pcs. Sealing tape (140155mm) (2)
- 3 pcs. Sealing compound (761310mm) (3)
- 1 pcs. Customized sealing strip (L= 2450mm) (4)
STEP 1: PREPARE THE UNIT FOR REWORK
Disassemble Outer housing
- Release the ten fastening screws and disassemble the top cover.
STEP 2: SEALING ON THE TOP COVER
Seal the connection pipe outlet on the top cover
- Place the sealing tape (1) along the edge of corrugated pipe outlet of top cover.
- Place the two sealing tapes (2) along the edge of top cover.
STEP 3: SEALING ON THE BASE PAN
Seal the edge of the base pan
- Unscrew the two screws of the clamp that fixes the corrugated pipe.
- Lift the clamp and the corrugated pipe and place the customized sealing strip (4) along base pan edge and under the corrugated pipe.
- Cut excessive sealing strip (if needed) and connect the sealing strip end-to-end.
STEP 4: SEALING ON THE CORRUGATED PIPE
- Place 1pc of sealing tape (1) on the corrugated pipe.
- Organize 1pc of sealing compound (3) to wrap the corrugated pipe evenly from bottom to top.
- Ensure both ends of sealing compound covers the sealing tape (1).
STEP 4: SEALING ON THE CORRUGATED PIPE
- Place 1pc of sealing tape (1) on corrugated pipe, along the edge of the first foam tape.
- Press the corrugated pipe and clamp to the metal base pan and screw the two screws to fix the clamp.
- Organize the sealing compound (3) marked in blue triangle to ensure the area is fully covered by sealing compound
STEP 4: SEAL OF WIRING AND CONDENSATE OPENING
Sealing of the wiring cut through
- Organize 1pc of sealing compound (3) and seal the wiring cut through in the EPP housing with it.
- Organize 1pc of sealing compound (3) and seal the passage of the condensate hose in the housing with.
STEP 5: ASSEMBLING OF TOP COVER
Preparing the customized sealing strip
-
For easier assembly dip soap water with soft cloth and apply on the outer side and on the top of customized sealing strip.
-
Put the plastic top cover on the unit.
-
Press the top cover at the outer edge of the sealing strip, and ensure the sealing strip is under the plastic top cover
**Caution!**
Press down the plastic top cover evenly at each corner and ensure that when the top cover is in place, no sealing strip is squeezed out. -
Fix the top cover with the screws
NOTICE: When reassembling the unit make sure that no cables are pinched and all lose parts (sealing material residues, etc.) are removed from the system.