mikroTIK RB5009UG+S+IN Routers and Wireless User Manual

June 4, 2024
Mikrotik

mikroTIK-logo

mikroTIK RB5009UG+S+IN Routers and Wireless

mikroTIK-RB5009UG+S+IN-Routers-and-Wireless-product

Safety Information

  • Before you work on any MikroTik equipment, be aware of the hazards involved with electrical circuitry, and be familiar with standard practices for preventing accidents. The installer should be familiar with network structures, terms, and concepts.
  • Use only the power supply and accessories approved by the manufacturer, and which can be found in the original packaging of this product.
  • This equipment is to be installed by trained and qualified personnel, as per these installation instructions. The installer is responsible for making sure, that the Installation of the equipment is compliant with local and national electrical codes. Do not attempt to disassemble, repair, or modify the device.
  • This product is intended to be installed indoors. Keep this product away from water, fire, humidity, or hot environments.
  • We cannot guarantee that no accidents or damage will occur due to the improper use of the device. Please use this product with care and operate at your own risk!
  • In the case of device failure, please disconnect it from power. The fastest way to do so is by unplugging the power plug from the power outlet.
  • This is a Class A product. In a domestic environment, this product might cause radio interference in which case the user might be required to take adequate measures

Electric shock hazard. This equipment is to be serviced by trained personnel only

Setup

  • Make sure your ISP is allowing hardware change and will automatically issue an IP address.
  • Connect your ISP cable to the first Ethernet port.
  • Connect your PC to any of the Ethernet ports.
  • Connect the device to the power source.
  • Use a Web browser or WinBox to connect to the default IP address of 192.168.88.1 from any port, with the username admin and no password.
  • If IP is not available, download WinBox from our webpage and use it to connect through MAC address.
  • Update RouterOS software to the latest version, make sure that the device has an internet connection.
  • If the device does not have an internet connection update software by downloading the latest version from our webpage https://mikrotik.com/download
  • Find the latest software and choose your packages.
  • To get the architecture type of your device model, open WinBox, WebFig go to (System/Resources).
  • Download packages to the PC and upload them to the WinBox, WebFig, (Files) menu, and reboot the device.
  • Set up your password to secure the device.

Powering

The power consumption under maximum load can reach 20 W. The device accepts power from the power jack or from the first Ethernet port:

  • Direct-input power jack (5.5 mm outside and 2 mm inside, female, pin-positive plug) accepts 24-57 V DC.
  • The First Ethernet port accepts Power over Ethernet 24-57 V DC.

Connecting to a POE Adapter:

  1. Connect the Ethernet cable from the device to the POE port of the POE adapter.
  2. Connect an Ethernet cable from your LAN to the LAN port of the POE adapter, please mind arrows for data and power flow.
  3. Connect the power cord to the adapter, and then plug the power cord into a power outlet.

Configuration

Once logged in, we recommend clicking the “Check for updates” button in the QuickSet menu, as updating your RouterOS software to the latest version ensures the best performance and stability. For wireless models, please make sure you have selected the country where the device will be used, to conform with local regulations. RouterOS includes many configuration options in addition to what is described in this document. We suggest starting here to get yourself accustomed to the possibilities: https://mt.lv/help. In case an IP connection is not available, the Winbox tool (https://mt.lv/winbox) can be used to connect to the MAC address of the device from the LAN side (all access is blocked from the Internet port by default).

For recovery purposes, it is possible to boot the device for reinstallation, see section Buttons and jumpers.

Mounting

The device is designed to use indoors and it can be mounted on the wall, or it can be placed on the desktop. mikroTIK-RB5009UG+S+IN-Routers-and-Wireless-
fig-1

  1. Find the designed mounting holes on both sides of the device, as shown in the picture;
  2. Use provided screws to secure the device to the wall;
  3. Based on the wall material you can use a drill bit and provided dowels.

The device has no protection from water contamination, please ensure the placement of the device in a dry and ventilated environment. We recommend Cat6 cables for our devices. The mounting and configuration of this device should be done by a qualified person.

Rackmount

If desired placement is rackmount, additional brackets can be purchased separately: RB5009 rackmount kit K-79.mikroTIK-RB5009UG+S+IN-Routers-and-
Wireless-fig-2

Extension slots and ports

  • Product code RB5009UG+S+IN
  • CPU 88F7040 1.4 GHz
  • CPU architecture ARM 64bit
  • CPU core count 4
  • Size of RAM 1 GB
  • RAM type DDR4
  • Storage 1 GB, NAND
  • Number of 1G Ethernet ports 7
  • Number of 2.5G Ethernet ports 1
  • Number of 10G SFP+ ports 1
  • USB port 1 (3.0 type A)
  • Operating system RouterOS (License level 5)
  • Switch chip model 88E6393
  • Dimensions 220 x 125 x 22 mm
  • Operating temperature -40°C to +60°C

Buttons and jumpers

The RouterBOOT reset button has the following functions. Press the button and apply the power, then:

  • Release the button when the green LED starts flashing, to reset the RouterOS configuration to defaults.
  • Release the button after LED is no longer lit (~20 seconds) to cause a device to look for Netinstall servers (required for reinstalling RouterOS over the network).

Regardless of the above option used, the system will load the backup RouterBOOT loader if the button is pressed before power is applied to the device. Useful for RouterBOOT debugging and recovery.

Accessories

The package includes the following accessories that come with the device:

  • ADAPT1_EU/US Switching Power Supply 24V 1.5A 36W
  • SET1_ K-55 fastening set
  • PAD1_ 4 pcs Pad D=7; H=1.5 mm, black, one side adhesive 3M988T

Please visit wiki pages for the MikroTik SFP module compatibility table: https://wiki.mikrotik.com/wiki/MikroTik_wired_interface_compatibility

Operating system support

The device supports RouterOS software version 7.0.5. The specific factory- installed version number is indicated in the RouterOS menu /system resource. Other operating systems have not been tested.

Federal Communication Commission Interference Statement

  • This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules.
  • These limits are designed to provide reasonable protection against harmful interference in a commercial installation.

This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense

FCC Caution:
Any changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate this equipment.

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:

  1. This device may not cause harmful interference, and
  2. This device must accept any interference received, including interference that may cause undesired operation.

Note: This unit was tested with shielded cables on the peripheral devices. Shielded cables must be used with the unit to ensure compliance.

CE Declaration of Conformity

EN Hereby, Mikrotīkls SIA declares that the radio equipment type RB5009UG+S+IN is in compliance with Directive 2014/30/EU. The full text of the EU declaration of conformity is available at the following internet address: https://mikrotik.com/products.

Technical Specifications

Product Power Input Options| Power Adapter Output Specification| Degrees of protection provided by enclosure (IP Code)| Operating Temperature
---|---|---|---
Voltage| Current
DC Jack = 12-57 V DC

PoE In Ethernet Port = 18-57 V DC 2-pin terminal = 12-57 V DC

| __

__

24 V

| __

__

1.5 A

| __

__

IP20

| __

__

-40°..+60°C

References

Read User Manual Online (PDF format)

Loading......

Download This Manual (PDF format)

Download this manual  >>