WATTS PWDWLCV2 2-Stage LCV Under Counter System Instruction Manual
- October 30, 2023
- WATTS
Table of Contents
- WATTS PWDWLCV2 2-Stage LCV Under Counter System
- Product Information
- Usage Instruction
- System Maintenance
- Operational Parameters
- Contents of Under Counter System
- Tools Recommended For Installation
- Installation Instruction
- Start-Up Instructions
- Filter Change
- Parts List
- Technical Data Sheet PWDWLCV2
- LIMITED WARRANTY
- References
- Read User Manual Online (PDF format)
- Download This Manual (PDF format)
WATTS PWDWLCV2 2-Stage LCV Under Counter System
Product Information
Model PWDWLCV2
The PWDWLCV2 is a water treatment system designed to fit under most kitchen
sinks. It is a 2-stage system that has been tested and certified by WQA
against NSF/ANSI Standard 372 for lead-free compliance.
Operational Parameters:
- Operational Temperature: 5°C to 40°C (41°F to 104°F)
- Operating Pressure: 35 psi to 100 psi
- pH Parameters: 6.5 to 8.5
- Flow Rate: 0.5 GPM @ 60 psig
Usage Instruction
Installation:
Installation needs to comply with state and local plumbing regulations. This
system is intended to be installed on the cold supply line only.
Tools Recommended For Installation:
- A small knife
- Variable speed drill
- 1/8 (3mm), 1/4 (6.4 mm) and 7/16 (11.0mm) drill bits
- 1 1/4 hole saw (for porcelain sinks) or 1 1/4 hole punch (for stainless steel sinks)
- 1/2 and 5/8 open-end wrenches (or adjustable wrenches)
- Phillips screwdriver
Contents of Under Counter System:
- 1 LCV Unit
- 2 Filters
- 1 Parts Bag
- 1 Faucet Assembly
If any of the items are missing, please contact Watts prior to installing.
Step-by-Step Installation Instructions:
Step 1:
-
Drill a Hole for the Faucet in a Porcelain Sink
OR -
Punch a Hole for the Faucet in a Stainless Steel Sink
Step 2:
Install the faucet.
Step 3:
Mount the Drinking Water Module. Do not cut any Drinking Water system tubes at
this time.
Step 4:
Install the Adapt-A-ValveTM. The water supply line to the system must be from
the cold water supply line only. Hot water will severely damage your system.
Do not use Teflon tape with the Adapt-A-ValveTM.
Start-Up Instructions:
Turn off the cold water supply to the faucet by turning the angle stop valve
completely off.
Maintenance:
The system should be tested periodically to verify that it is performing
satisfactorily. Discard small parts remaining after installation. The failure
to install the system correctly voids the warranty. Handle all components of
the system with care. Do not drop, drag or turn components upside down. Be
sure the floor under the water filter system is clean, level and strong enough
to support the unit.
WARNING
Please read carefully before proceeding with the installation. Your failure to
follow any attached instructions or operating parameters may lead to the
product’s failure. Keep this Manual for future reference.
WARNING
Do not use water that is microbiologically unsafe or of unknown quality
without adequate disinfection before or after the system.
IMPORTANT
If you are unsure about installing your Watts® water filter, contact a Watts
representative or consult a professional plumber.
CAUTION
Test the water periodically to verify that the system is performing
satisfactorily. Discard small parts remaining after the installation.
NOTICE
Failure to install the system correctly voids the warranty. Handle all
components of the system with care. Do not drop, drag or turn components
upside down. Be sure the floor under the water filter system is clean, level
and strong enough to support the unit.
System tested and certified by WQA against NSF/ANSI Standard 372 for lead-free compliance.
Thank you for your purchase of a state-of-the-art Watts® Pure Water Treatment system.
PWDWLCV2 Water Treatment System:
Watts Pure Water PWDWLCV2 water treatment system contains a heavy-duty lead
and VOC filter block. This specialty-formulated block is capable of reducing
lead, as well as harmful Volatile Organic Chemicals. It is estimated that VOCs
are present in one-fifth of the nation’s water supplies. These water
contaminants can enter groundwater from a variety of sources including
localized use of herbicides and pesticides, gasoline or oil spills, leaking
underground fuel tanks, septic system cleaners, and chemicals used in the dry-
cleaning industry.
System Maintenance
Just because you can not taste it, does not mean that it is not there. Many contaminants in the drinking water are undetectable to the taste. Additionally, over time if you do not replace the filter element, other bad tastes and odors will be apparent in your drinking water. This is why it is important to change out your filter at the recommended intervals as indicated in this system manual. When replacing any of the filter elements, pay special attention to any cleaning instructions. Should you have any further questions please refer to our website at www.watts.com/purewater or call our customer service department at 1-800-244-1299.
Maintenance Record
Operational Parameters
Installation needs to comply with state and local plumbing regulations. This system is intended to be installed on the cold supply line only.
MAXIMUM | MINIMUM |
---|---|
Operational Temperature | 100°F (37.8°C) |
Operating Pressure | 85psi (5.98 kg/cm²) |
pH Parameters | 10 |
Flow Rate | 0.5 GPM @ 60 psig |
Contents of Under Counter System
- 1 LCV Unit
- 2 Filters
- 1 Parts Bag
- 1 Faucet Assembly
If any of the items are missing, please contact Watts prior to installing.
Tools Recommended For Installation
- A small knife
- Variable speed drill
- 1⁄8″ (3mm), 1⁄4″ (6.4 mm) and 7⁄16″ (11.0mm) drill bits
- 11⁄4″ hole saw (for porcelain sinks) or 11⁄4″ hole punch (for stainless steel sinks)
- 1⁄2″ and 5⁄8″ open-end wrenches (or adjustable wrenches)
- Phillips screwdriver
Installation Instruction
STEP 1
Drill a Hole for the Faucet in a Porcelain Sink
NOTICE
Most sinks are predrilled with 1½” or 1¼” diameter hole that you can use for
your RO faucet. (If you are already using it for a sprayer or soap dispenser,
see Step 2).
NOTICE
Porcelain sinks are extremely hard and can crack or chip easily. Use extreme
caution when drilling. Watts accepts no responsi-bility for damage resulting
from the installation of faucet.
- Step A – Determine desired location for the RO faucet on your sink and place a piece of masking tape on over where the hole is to be drilled. Mark the center of the hole on the tape.
- Step B – Using a variable speed drill set on the slowest speed, drill a 1⁄8“ pilot hole through both porcelain and metal casing of sink at the marked center of the desired location. Use lubricating oil or liquid soap to keep the drill bit cool (If drill bit gets hot it may cause the porcelain to crack or chip).
- Step C – Using a 1¼” hole saw, proceed to drill the large hole. Keep drill speed on the slowest speed and use lubricating oil or liquid soap to keep the hole saw cool during cutting.
- Step D – Make sure the surroundings of the sink are cooled before mounting the faucet to the sink after drilling and remove all sharp edges.
Punch a Hole for the Faucet in a Stainless Steel Sink
NOTICE
If mounting faucet to a Stainless Steel Sink you will need a 1¼” Hole Punch.
The faucet opening should be centered between the back splash and the edge of
the sink, ideally on the same side as the vertical drain pipe.
- Step A – Drill a ¼” pilot hole. Use a 1⁄2″ Hole Punch and an adjustable wrench to punch the hole in the sink. Change to the 1¼” Hole Punch to enlarge the hole The faucet can now be installed.
STEP 2
- Step a – Under the sink – on to the threaded faucet stem in order first slide on the plastic spacer (Item 7), the washer (Item 8), the slotted washer (Item 9), and lastly secure with nut (Item 10).
- Step D – Locate the blue 1/4” tube in the faucet parts bag. Remove a brass nut (Item 13), plastic sleeve (Item 12) and insert (Item 11) from the parts bag. To assemble, place the brass nut on the blue tube first, then the sleeve (small tapered end of sleeve must point to the end of tube) and then push the insert all the way into the end of the tube.
- Step E – Insert the blue tube into the end of the faucet shank and use a wrench to tighten the brass nut securely.
NOTICE
DO NOT overtighten nut.
Drinking Water Module Mounting
Step A
Determine best location for the Drinking Water system to be mounted to allow
for future system maintenance. The parts bag has 2 self tapping screws. Using
an electric drill with a Phillips bit, screw them into the cabinet wall 6″
apart and 16″ from the bottom of the cabinet.
NOTICE
Do not cut any Drinking Water system tubes at this time
STEP 4
Adapt-A-Valve™ Installation
Verify contents prior to installation:
- ( 1 ) – Plastic Adapt-a-Valve™ & Black Collet
- ( 1 ) – Brass Adapter no washer
- ( 1 ) – Brass Adapter with black washer
- ( 1 ) – White rubber washer
NOTICE
Water supply line to the system must be from the cold water supply line
only. Hot water will severely damage your system. Do not use Teflon tape with
the Adapt-A-Valve™.
For 3⁄8″ Configuration
For 1⁄2″ Configuration
- Step A – Turn off the cold water supply to the faucet by turning the angle stop valve completely off.
- Step B – Open cold water sink faucet to relieve pressure.
- Step C – Choosing the configuration that fits your plumbing, attach the Adapt-A-Valve™ as illustrated in the four photos above.
Start-Up Instructions
Step A
Turn on the incoming cold water at the angle stop valve. Turn the knob on
the Adapt-A-Valve™ by turning counterclockwise. Check the system for leaks and
tighten any fittings as necessary. (Check frequently over the next 24 hours to
ensure no leaks are present).
If you have connected your RO system to a refrigerator/ice maker, make sure the ice maker is off (do not allow water to flow to the ice maker) until flushing is complete and the tank has been allowed to fill completely. Connection from the RO to the ice maker system should have an in-line valve installed before the ice maker so it can easily be closed to prevent water from flowing to the ice maker during start-up and periodic maintenance. Your RO tank must be allowed to fill up fully in order for the ice maker system to work properly.
Step B
Turn faucet handle to the open position to start the flow of water through the
unit. Run 7 gallons of water through the unit in order to flush out the normal
black carbon fines (it will “sputter” until the air is purged out) from the
unit. Initially, the water may appear cloudy which is due to tiny air bubbles
and it will clear up shortly. Close the faucet.
Step C
Check for leaks. If you have any leaks, shut off the water supply to your
system, repair it, and restart the unit.
Filter Change
Order filter by calling Watts at 1-800-224-1299
Watts recommends changing the filter element every 6 months.
Use Watts replacement cartridge only. Other filters may look the same, but only filters by Watts are manufactured to fit your LCV filter unit in order to ensure proper reduction of water contaminants.
Replacement Filters Pack
MODEL | FREQUENCY | DESCRIPTION |
---|---|---|
PWFPKLCV | 6 Months | PWMB10M5 (5-micron sediment filter) & PWCB10LCV (1 micron |
carbon filter)
NOTICE
Water conditions may require more frequent cartridge replacement
- Turn off the incoming water supply to the LCV unit by turning the KNOB on the Adapt-A-Valve™ clockwise. Note: There will be water in the filter housing. Lift the faucet handle to relieve the water pressure.
- Remove the filter housing from lid by turning it to the left, as shown in Figure D.
- Remove the used filter cartridge and discard.
NOTICE
Do not discard the filter-housing O-ring.
- Clean the inside of the filter housing with warm soapy water and rinse to remove soap
- Lubricate the O-ring with water-soluble lubricant (i.e. K-Y Jelly® or Silicone lubricant).
NOTICE
Do not use Petroleum based lubricants such as Vaseline®.
- Seat the O-ring in a groove in the filter housing and insert new filter cartridges into the filter housing.
- Screw filter housing onto the lid as shown in Figure D.
- Turn on the water supply to the filter unit by turning a knob on Adapt-A-Valve™ counterclockwise
- Check the system for leaks.
Parts List
ITEM | EDP | DESCRIPTION |
---|---|---|
1 | 7300068 | ADAPT-A-VALVE™ |
2 | 7300031 | ELBOW – 1/4″ C X 1/4″ M |
3 | 7300081 | FILTER HOUSING – LID – 1/4″ PORTS |
4 | 7300044 | FILTER HOUSING – BOWL – 10″ – WHITE |
5 | 7300060 | O-RINGS FOR FILTER HOUSING |
6 | 7100331 | SEDIMENT FILTER |
7 | 7100451 | LEAD, VOC Carbon Block |
8 | 7100188 | FAUCET – CHROME |
9 | 7300066 | 1/4″ GREEN TUBING |
10 | 7300065 | 1/4″ BLUE TUBING |
Technical Data Sheet PWDWLCV2
GENERAL USE CONDITIONS:
- System to be used with municipal or well water sources treated and tested on a regular basis to ensure bacteriologically safe quality. DO NOT use water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system. Systems certified for cyst reduction may be used on disinfected waters that may contain filterable cysts.
- Operating Temperature:
- Maximum 100o F (37.8o C)
- Minimum 40o F (4.4o C)
- Operating Water Pressure:
- Maximum 85psi (5.98 kg/cm2)
- Minimum 20psi (1.406 kg/cm²)
- Maximum flow Rate: 0.50 gpm (1.89 lpm)
- Rated Capacity: 600 Gallons (2,200 liters)
RECOMMENDED REPLACEMENT PARTS AND CHANGE INTERVAL:
Note:
Depending on incoming feed water conditions replacement time frame may vary.
Description | Part Number | Change time Frame |
---|---|---|
Stage 1: Sediment filter | 7100331 | 6 Months or 600 gallons of water |
Stage 2: Lead, VOC Carbon block | 7100451 | 6 Months or 600 gallons of water |
LIMITED WARRANTY
Certain Watts Pure Water products come with a limited warranty from Watts Regulator Co. Other products may have no warranty or are covered by the original manufacturer’s warranty only. For specific product warranty information, please visit www.watts.com or the published literature that comes with your product. Any remedies stated in such warranties are exclusive and are the only remedies for breach of warranty. EXCEPT FOR THE APPLICABLE PRODUCT WARRANTY, IF ANY, WATTS MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED. TO THE FULLEST EXTENT PERMITTED BY APPLICABLE LAW, WATTS HEREBY SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, AND IN NO EVENT SHALL WATTS BE LIABLE, IN CONTRACT, TORT, STRICT LIABILITY OR UNDER ANY OTHER LEGAL THEORY, FOR INCIDENTAL, INDIRECT, SPECIAL OR CONSEQUENTIAL DAMAGES, INCLUDING, WITHOUT LIMITATION, LOST PROFITS OR PROPERTY DAMAGE, REGARDLESS OF WHETHER IT WAS INFORMED ABOUT THE POSSIBILITY OF SUCH DAMAGES.
USA: T: (800) 224-1299 • F: (978) 794-1848 •
Watts.com/PureWater.
Canada: T: (888) 208-8927 • F: (905) 481-2316 •
Watts.ca/PureWater.
Latin America: T: (52) 55-4122-0138 •
Watts.com/PureWater.
References
- Watts | Plumbing, Heating and Water Quality Solutions
- Water Quality & Rainwater Harvesting Solutions
Read User Manual Online (PDF format)
Read User Manual Online (PDF format) >>